Out of Band Spurious
Input Power
Output Power
Modulation Type
Operating Instantaneous Bandwidth
Input Return Loss
Output Return Loss
Output Protection
Duty Cycle
Vdc Input Power
Operating Current
MAF800-100S Environmental Specifications:
Parameter
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
RF Input / Output Connector
Status / Alarm / Control / DC Input Connector
Dimensions
Weight
Section 3

Principals of Operation

3.1 Introduction
This section contains the functional description of the MAF800-100S multi-carrier power amplifier.
3.2 RF Input Signal
The maximum composite input power shall not exceed – 4 dBm. The reference source signal shall not
exceed the base station manufacture minimum requirements for intermodulation distortion. For proper loop
balance, the out of band components of the input signal shall not exceed –40 dBc. The input VSWR should
be 2:1 maximum
3.3 RF Output Load
The load impedance should be equal to or better than 1.5:1 in the operating band for good power transfer to
the load. If the amplifier is operated into a filter, it will maintain its distortion characteristics outside the
signal band even if the VSWR is infinite. Provided the reflected power does not exceed one-watt. A
parasitic signal of less than one-watt incident on the output will not cause distortion at a higher level than
the normal forward distortion
≤ -13 dBm
-4 dBm
100 Watts
AMPS, CDMA, CDMA 2000, TDMA, EDGE, GSM, 1x
EV-DO
25 MHz
≥ 15 dB
≥ 15 dB
Mismatched Protected
Continuous
+27 Vdc
24 amps per amplifier
Specification
0 ° C. to 50 ° C.
-40 ° C. to + 80 ° C.
5%- 95% Relative Humidity (Non-condensing)
5%-95% Relative Humidity (Non-condensing)
D-Sub, Hybrid, Plug-in Type RF Connector: PKZ
26-0020 series straight plug (Phoenix Co.)
21 Pin D-Subminiature Combo Connector