Exercise care in handling equipment during inspection to prevent damage caused by rough or careless
handling.
1.
Visually inspect the MAF800-100S MCPA for damage that may have occurred during shipment.
2.
Check for evidence of water damage, bent or warped chassis, loose screws, nuts or extraneous
packing material in the connector(s).
Before applying power, make sure that all connectors to the MAF800-100S are secure. Make sure that the
input and output of the amplifier is terminated to 50 ohms. Do not operate the system without a load
attached. Excessive input power may damage the equipment.
If possible, inspect the equipment in the presence of the delivery person.
If the equipment is damaged:
The carrier is your first recourse.
A claim should be filed with the carrier once the extent of damage is assessed. Careful, immediate
inspection is important if the carrier is suspect of damage.
If the equipment is damaged and must be returned to the factory:
Contact your Paradigm Wireless Systems representative.
Paradigm Wireless Systems may not accept returns without an RMA.

5.4 Installation Instructions

Model MAF800-100S MCPA is designed for use in a Cellular Radio Base Station. The host enclosure must
permit access to the sub-rack for DC power, RF and alarm cables as well as proper ventilation of sub-rack
the assembly.
Verify that all circuit breakers on the MAF800-100S MCPA are in the OFF position before installation in
sub-rack. Turn OFF all external power to the sub-rack before installing MAF800-100S MCPA
1.
Install sub-rack into host radio base station and secure it into place using #10 32x1/2 Phillips
screws and #10 flat washers.
2.
Connect +27 Vdc using #6 gauge wire. 1- Positive (red) 1- Return/Ground (black).
3.
Connect RF IN cable to sub-rack