User Manual
Blood Pressure Monitor
Thank you for purchasing a ZEWA Blood Pressure Monitor .
To use the monitor correctly and safely, please read the manual thoroughly.
version:1.0
UAM-880
Arm Type

Advertisement

Table of Contents
loading

Summary of Contents for zewa UAM-880

  • Page 1 User Manual Blood Pressure Monitor UAM-880 Arm Type Thank you for purchasing a ZEWA Blood Pressure Monitor . Manufactured for Zewa, Inc. 12960 Commerce Lakes Drive#29 Fort Myers, FL 33913 USA To use the monitor correctly and safely, please read the manual thoroughly.
  • Page 2: Table Of Contents

    CATALOGUE CATALOGUE Table of Contents INTRODUCTION........................2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START......................9 The Choice of Power Supply Installing and Replacing the Batteries Setting Date and Time Select the User MEASUREMENT.........................13 Tie the Cuff Start the Measurement...
  • Page 3: Introduction

    Then it starts inflating the cuff. Readings taken by the UAM-880 are equivalent to those obtained by a Meanwhile, the unit detects pressure oscillation generated by beat-to-beat trained observer using the cuff and stethoscope auscultation method.
  • Page 4 INTRODUCTION INTRODUCTION CAUTION CAUTION * This device is intended for adult use in homes only. * The device cannot be used with HF surgical equipment at the same time. * The device is not suitable for use on neonatal patients, pregnant women,patients with * The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, was clinically investigated according to the requirements of ISO 81060-2:2013.
  • Page 5: Lcd Display Signal

    * If you have any problems with this device, such as setting up, maintaining or using, please Low blood pressure Diastolic blood pressure contact the SERVICE PERSONNEL of ZEWA. Don’t open or repair the device by yourself in the event of malfunctions. The device must only be serviced, repaired and opened by Pulse display Pulse in beats per minute individuals at authorized sales/service centers.
  • Page 6: Monitor Components

    Replace the batteries whenever the below happens 1. Blood Pressure Monitor 2. Cuff ( 22~42cm) 3. 4*AA Batteries shows (UAM-880) (Type BF applied part) The display dims The display does not light up CAUTION Do not use new and used batteries together.
  • Page 7: Setting Date And Time

    BEFORE YOU START BEFORE YOU START Setting Date and Time 4.Repeat step 2 and 3 to set the [MONTH] and [DAY]. It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that is stored in the memory.
  • Page 8: Select The User

    BEFORE YOU START MEASUREMENT Tie the Cuff Select the User Remove all jewelry, such as watches and 1.When the monitor is off , press the “ ” button shortly to enter bracelets from your left arm. user setting mode. Note: If your doctor has diagnosed you with poor circulation in your left arm, use your right arm.
  • Page 9: Start The Measurement

    MEASUREMENT DATA MANAGEMENT 2.This device will proceed to data transmission after measurement.The Bluetooth Start the Measurement symbol blinks on the LCD indicates data is transmitting. 1.When the monitor is off,press the “ ” button to turn on the monitor, and it will finish the whole measurement.
  • Page 10: Recall The Records

    CAUTION Interference may occur in the vicinity of equipment marked with the following symbol . And UAM-880 may interfering vicinity electrical equipment. Sensitive people, including pregnant women pre-eclamptic and those who implanted medical electronic instruments, should avoid using the unit whenever possible.
  • Page 11: Delete The Records

    DATA MANAGEMENT DATA MANAGEMENT Delete the Records 3: To exit the delete mode without deleting any records, press “ ” button before pressing " " button to confirm any You can delete all results of the selected user by following steps delete commands.
  • Page 12: Information For User

    INFORMATION FOR USER INFORMATION FOR USER Maintenance Tips for Measurement In order to get the best performance, please follow the Measurements may be inaccurate if taken in the following instructions below. circumstances. Avoid touching water, Immediate measurement Put in a dry place and avoid the sunshine clean it with a dry cloth in case.
  • Page 13: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE Why does my blood What are systolic pressure and diastolic pressure? pressure fluctuate When ventricles contract and pump blood out Systolic Diastolic throughout the day? of the heart, the blood pressure reaches its blood discharging blood entering maximum value in the cycle, which is called vein...
  • Page 14: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS This section includes a list of error messages and frequently Battery powered mode: 6VDC 4×AA batteries asked questions for problems you may encounter with your blood AC adaptor powered mode: 1A (Not inicluded) pressure monitor. If the product is not operating as you think it Power supply (Please only use the recommended AC should, check here before arranging for servicing.
  • Page 15: Authorized Component

    -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. For more information about our products or online support, please visit www.zewa.com. -- Connect the equipment into an outlet on a circuit different from that to To contact our customer service, please call 888-993-3592 or support@zewa.com.
  • Page 16: Complied Standards List

    EMC GUIDANCE EMC GUIDANCE Complied Standards List EMC Guidance EN ISO 14971:2012 / ISO 14971:2007 Medical devices - Application Risk management 1)This product needs special precautions regarding EMC and needs to be of risk management to medical devices installed and put into service according to the EMC information provided, EN ISO 15223-1:2016 / ISO 15223-1:2016 Medical devices.
  • Page 17: Emc Guidance

    EMC GUIDANCE EMC GUIDANCE Table 3 Table 2 Guidance and manufacturer’s declaration – electromagnetic immunity Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 18 EMC GUIDANCE EMC GUIDANCE Table 5 Table 4 Recommended separation distances between portable and mobile RF communications Guidance and manufacturer’s declaration - electromagnetic immunity equipment and the device. The device is intended for use in the electromagnetic environment specified below. The customer or the The device is intended for use in an electromagnetic environment in which radiated RF disturbances are user of the device, should assure that it is used in such an environment.