Carefully read the instruction manual before using this
device. Be sure to comply with all "CAUTIONS" and
"WARNINGS" in the manual. Failure to follow the instruc-
tions may be harmful to user or damage the device. Keep
this manual in a safe place for future reference.
WARNING:
To avoid accidents, keep the TENS device away from
children and the infirm.
If you do not understand any part of these instructions,
contact Zewa Customer Service at 1-888-993-3592.

Advertisement

Table of Contents
loading

Summary of Contents for zewa SpaBuddy Mini Go

  • Page 1 Keep this manual in a safe place for future reference. WARNING: To avoid accidents, keep the TENS device away from children and the infirm. If you do not understand any part of these instructions, contact Zewa Customer Service at 1-888-993-3592.
  • Page 2: Table Of Contents

    Statement Of Intended Purpose ....3 How SpaBuddy Mini GO Works....3 TENS Efficacy ..........4 Unpacking Your SpaBuddy Mini GO ....4 Parts of the SpaBuddy Mini GO ......5 Contra-Indications, Safety Instructions and Precautions ............6 Usage ............6 Device Use Warnings ........
  • Page 3: Introduction

    Statement of Intended Purpose The SpaBuddy Mini GO is a high frequency medi- cal device intended for the relief of both acute and chronic pain. This device may be used to relieve...
  • Page 4: Tens Efficacy

    Unpacking Your TENS Remove and examine the carton’s contents to ensure all the listed items are supplied and are undamaged. If an item is missing or damaged call Zewa Customer Service at 1-888-993-3592.
  • Page 5: Parts Of The Spabuddy Mini Go

    ● 1 x 3V CR2032 Battery ● 1 x User Manual Parts of the SpaBuddy Mini GO The parts of the SpaBuddy Mini GO device and electrode pad are shown below in Figure 1. FIGURE 1: The parts of the SpaBuddy Mini GO...
  • Page 6: Contra-Indications, Safety Instructions And Precautions

    ● Place the SpaBuddy Mini GO electrode pad only on healthy, clean and dry skin. Do not place it on open wounds, rashes, scars or over...
  • Page 7: User Precautions

    ● Do not use this device on skin areas that lack normal sensations, including skin that tingles, feels “pins and needles” or is numb. ● Do not use this device when asleep, driving, operating machinery, swimming or bathing. ● The safe use of TENS therapy during pregnan- cy has not been established.
  • Page 8: Adverse Reactions

    Adverse Reactions Side effects of TENS therapy are generally mild, even with extended use. The most common side- effects include: Muscle Soreness and Twitching The constant pulsing of TENS therapy can cause muscle soreness and twitching due to electrical over-stimulation. This condition generally allevi- ates by applying shorter treatment times or de- creasing the frequency of daily therapy.
  • Page 9: Installing Or Changing The Device Battery

    Installing or Changing the Device Battery FIGURE 2: BATTERY REPlACEMENT Install or change the battery in this device by slid- ing the battery compartment cover, located at the back of the device, to the right. Insert a CR2032 battery in the battery compartment with the posi- tive (+) polarity facing up (See Figure 2).
  • Page 10: Electrode Pad Skin Placement

    Electrode Pad Skin Placement Ensure the skin is clean and dry before placing the electrode pad. Remove the plastic film from the electrode pad by holding the edge of electrode and peeling it away from the plastic. Place elec- trode pad on the selected skin and smooth it down with firm pressure.
  • Page 11: At The Completion Of Treatment

    At the Completion of Treatment Never remove the TENS device from the skin while it is switched on. Remove the electrode pad from the skin by lifting it at the edge and pulling carefully. Replace the electrode pad directly back onto the plastic film. ⓘ...
  • Page 12: Electrode

    20 minute duration. Replace the electrode pad when it is no longer ad- hesive, cracks or becomes discolored. Use only original SpaBuddy Mini GO Self Adhe- sive Electrode Pads. Store the electrode pad on the protective plastic film, in a cool, dry place.
  • Page 13: Troubleshooting Guide

    Troubleshooting Guide Problem Cause Remedy LED fails to No battery in the Replace the illuminate device or the battery battery is flat Insert battery Battery is insert- with the positive ed incorrectly (+) facing up Switch the de- The device is not vice on switched on Remove the...
  • Page 14: Disposal

    Contact Zewa Customer Service at 1-888-993- 3592, if your problem does not rectify. ⓘ NOTE: ● Do not disassemble the TENS device as it can- not be serviced at home. ● Unauthorised disassembly of this device will void the warranty.
  • Page 15: Device Certification

    Technical Specifications SpaBuddy Mini GO Channel Single Channel Output Voltage 0~30V +/- 20% (at 500 Ohm load) Pulse intensity Adjustable from 0~60mA +/- Pulse Width 150~250 µS Pulse Rate 30~60 Hz Power Source 1 lithium Cell Battery CR-2032 Timer 20 minutes Operating 50°F to 104°F (10°C to 40°C)
  • Page 16: Appendix 1

    This manual provides a series of body maps to illustrate electrode positioning for various painful conditions. The body maps provided have been selected on the basis of the SpaBuddy Mini GO appropriateness in the treatment of the complaint. Correct electrode placement will improve the effi- ciency of pain relief therapy.
  • Page 17: Placement Of Electrode

    Placement of Electrode...
  • Page 18 Manufactured for Zewa, Inc. 12960 Commerce Lakes Dr. # 29 Fort Myers, FL 33913 www.zewa.com Toll Free Customer Service: 1-888-993-3592 Made In Taiwan IM-23-047 RevA18 FDA-2301A...