  • Page 1 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Cat 6A Interactive Reference Guide...
  • Page 2: Installation

    Cat 6A Installation Applications Testing Overview Termination References Cat 6A Testing Termination Where is Cat 6A used? Cat 6A Testing Termination Tips Standards AXT Testing 110-Style Patch Panel Termination Instructions Network Migration AXT Testing Preparation Atlas-X1 UTP Connector Copper Cable Terms and Types...
  • Page 3 Use this guide to gain a better understanding of these requirements to help you efficiently plan, bid, and install a Cat 6A structured cabling system for networks up to 10 gigabit Ethernet. This guide will also cover the general areas and applications where Cat 6A may be deployed, and give you an overview of Leviton’s Cat 6A system connectivity.
  • Page 4 Category 6A cabling systems have come a long way since the original “augmented Category 6” standard was first introduced in 2008. Today, Cat 6A is a popular specification for data center and other enterprise applications. The move to Cat 6A has been driven by several factors, including support for 10G networks, long-term planning for workstation areas, Power over Ethernet (PoE) applications, and new wireless access points.
  • Page 5 100 meters on a single category-rated twisted-pair cable. The HDBaseT Alliance specifies Cat 5e, Cat 6 UTP, and Cat 6A UTP cabling as supported media types. But these category ratings will deliver varying performance results, with Cat 6A more capable of supporting higher bandwidth signals such as 4K.
  • Page 6 Cat 6A requirements are addressed in standards from multiple organizations. Regardless of the standard, all Cat 6A cabling will provide 10 Gb/s data rates, operate at a maximum frequency of 500 MHz, and have a maximum distance of 100 meters.
  • Page 7 IEEE 802.3bt four-pair PoE enterprise data centers and multi-tenant Internet hosting data centers. Wireless Access Points: Note: Cat 6A is recommended for horizontal cable in data centers using 100 ohm balanced twisted pair. TSB-162-A Telecommunications Cabling Guidelines for Wireless...
  • Page 8 Standard: ISO/IEC 11801-1 Information (Technology — Generic Cabling for Customer Premises; Class E Specification) Defines: Class E cabling and component performance requirements for customer premises. ISO equivalent of Cat 6A Power over Ethernet: The ISO/IEC 11801-6 Distributed Building Services standard raises cabling requirements to Category 6A to better support IEEE 802.3bt four-pair PoE...
  • Page 9: Network Migration

    End users and building owners who are planning for network upgrades or new construction in the near future should consider Cat 6A as a way to extend the expected life of their cabling systems.
  • Page 10 (7 - 8 mm) (7 - 8 mm) (7.4 - 8.3 mm) (7 - 8 mm) (7.4 - 8.3 mm) ( 7 mm) Cat 6A > Copper Cable Terms and Types Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 11 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Installation Routing and Handling Pathways and Spaces Telecommunications Rooms Work Area Installation Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 12 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Routing and Handling Cable Reels Cable Pulling Bundling Placement Bend Radius Slack Loops Pulling Lubricants Installation > Routing and Handling Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222...
  • Page 13 Termination References Routing and Handling Cat 6A cables are larger and heavier than Cat 6 and earlier cables, and they require modifications to older cable routing and handling techniques. The following tips will help ensure a smooth installation. Cable Reels...
  • Page 14 To maintain Cat 6A performance, minimum bend radius should be 4x OD for UTP and shielded cable. This radius is significantly larger than Cat 6 and 5e. For example, Cat 6 cables at 4x OD is 0.904", whereas Cat 6A is 1.21". Plan carefully to ensure there is sufficient space throughout cable runs to maintain proper bend radius.
  • Page 15 Cable slack in bundled or excessive loops has been shown to degrade cable performance and is associated with return loss failures. Plan carefully to ensure there is sufficient space and support for heavy Cat 6A cable slack loops.
  • Page 16 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Pathways and Spaces Cable Tray Fill Conduit Fill Cable Tray Sizing Example Firestopping Structural and Cable Supports Consolidation Points and Zone Enclosures Ensure Shielded Category 6A Integrity Installation >...
  • Page 17 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Pathways and Spaces CABLE CAPACITY FOR TRAYS AND CONDUIT CAT 5E CAT 6 CAT 6A Cable Tray Fill UTP with Shielded TIA-569-D recommends 25% fill at initial installation and Isolation Wrap up to 50% with unplanned additions.
  • Page 18 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Pathways and Spaces Cable Tray Sizing Example To determine the proper tray size based on 25% fill, use the following calculation for cable with outer diameter of 0.30 inches (8 mm): Cable OD No.
  • Page 19 Ceiling Space Structural and Cable Supports • Stronger anchors and threaded rods are needed to support heavier Cat 6A cable • Use properly sized J hooks and other supports to accommodate bundle size • Limit bundles to 50 cables to prevent damage to cables on the bottom •...
  • Page 20 TIA standards allow an optional consolidation point (CP) within a permanent link. A Cat 6A 110 block is Leviton’s standard CP solution. It has a density that is 1/3 less than Cat 6 110 blocks (64-pair Cat 6A Minimum of 15 m capacity versus 96-pair for Cat 6 in the same footprint).
  • Page 21 The general best practices below highlight the grounding/bonding elements within a single telecommunications room. You can download an expanded list of grounding best practices from Leviton (pdf). Refer to the TIA-607-C standard for additional TEBC elements required for a larger Telecommunications Grounding System.
  • Page 22 Organizing cable runs at racks and cabinets is essential to a well-managed network. Larger, heavier Cat 6A cables may require special planning and equipment for a successful installation. Select the best patch panels, cable management, and patch cords or trunks for your application to speed installation and simplify ongoing management.
  • Page 23 Telecommunications Rooms TECH TIP: Routing and Patching Cables with One Rear Cable Manager Follow the suggestions below for managing and dressing Cat 6A cables using a single rear cable management bar with a 2RU 48-port flat patch panel. 1. Split the cable bundle before routing it to the 4.
  • Page 24 Versi-Duct vertical managers, as the angled design eliminates the need for horizontal managers. Also consider Leviton Atlas-X1 Cat 6A SlimLine Boot patch cords: Their low profile boots will reduce congestion at the face of the patch panel and on high-density switch equipment.
  • Page 25 48 ports per rack unit. However, one • A/B switch fabric for data center redundancy should factor in Cat 6A cable size when considering high-density panels, as too many • Connectivity types such as WAN/corporate data, panels in a rack or cabinet may create unwanted congestion.
  • Page 26 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Telecommunications Rooms — Leviton Solutions Pre-Terminated Copper Trunks Patch Panels Vertical Cable Management Horizontal Cable Management Installation > Telecommunications Rooms > Leviton Solutions Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 27 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Work Area Connectivity in the work area requires a finished look, ease of maintenance, and performance, all while meeting installation codes and guidelines. Simplify work area connectivity planning, design, and installation with the following tips.
  • Page 28 — Cabling In-Wall Applications Drop Ceiling Applications Cat 6A cables require additional depth behind faceplates Cable infrastructure must be independently suspended by components and at all directional changes to maintain proper bend designed for this purpose, separate from all other building systems.
  • Page 29 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Work Area — Cabling Consolidation Points and Zone Cabling In a zone cabling design, cables are routed from the telecommunications room (TR) to appropriately placed zone enclosures or telecommunications enclosures (TE). Cabling is then run from the zone enclosure to each work area (WA).
  • Page 30 Junction Boxes and Mud Rings Verify that the connectivity design specifies the proper junction box size before drywall is installed. Consider an oversized junction box to accommodate Cat 6A cabling and bend radius requirements, box eliminators, or Leviton QuickPlate ®...
  • Page 31 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Work Area — Leviton Solutions Connectors In-Ceiling and In-Wall Brackets Patch Cords Zone Enclosures Wallplates Surface-Mount Boxes Installation > Work Area > Leviton Solutions Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 32 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Applications Data Centers Wireless Access Points Power over Ethernet IT/AV and HDBaseT Applications Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 33 Cabling for data centers differs from horizontal installations in several ways: typical distances, network function, pathways, and spaces. Cat 6A cabling may affect requirements for all of these, but especially pathways and spaces. Careful planning and proper specifications will help ensure a successful installation.
  • Page 34 40G Fiber Uplinks pathways, as cabinet and cable tray space may become an issue. Cat 6A cabling used to support the 10GBASE-T server connections has a significant impact on the physical support infrastructure needed to deploy it. Higher density example: 8-Cabinet Row with Cisco Nexus 9508 Switch Applications >...
  • Page 35 18 for cable tray sizing in pathways. There are three typical data center Cat 6A cable run configurations: power and data cabling both under a raised floor, both overhead, or power below and data overhead. Space cable bundle supports every three to four feet The chosen configuration will affect other data center design elements: (0.9-1.2 meters) at irregular intervals.
  • Page 36 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Data Centers — Leviton Solutions Pre-Terminated Trunks Atlas-X1 Connectors Atlas-X1 Cords ™ High-Density vs. Standard Panels Cable Management OIP (Overhead Infrastructure Platform) Applications > Data Centers > Leviton Solutions...
  • Page 37: Wireless Access Points

    In late 2013, TIA published TSB-162-A, Telecommunications Cabling Guidelines for Wireless Access Points, which revises recommendations for mounting and routing cable between LAN equipment and WAPs. TIA and Leviton Cabling Recommendations Plenum Cabling Systems for WAPs Leviton Solutions Applications >...
  • Page 38 Patch Panel Equip. Cord EO EO EO EO Run at least two Cat 6A cable runs to each cell in the grid architecture. Max = 6m (20ft) As 802.11ac WAPs allow for Power over Ethernet (PoE), it is recommended Active Equipment to run two Cat 6A cables to each WAP for backup power capabilities in case one power source isn’t working.
  • Page 39 Many wireless access points are installed in drop ceilings, which means the cabling system may require a plenum rating to meet requirements for flammability and smoke density in air-handling spaces. Leviton offers a complete plenum-rated in-ceiling system which includes patch cords, cable, Atlas-X1...
  • Page 40 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Wireless Access Points — Leviton Solutions In-Ceiling Bracket Plenum-Rated Surface-Mount Box Patch Cords Atlas-X1™ QuickPort Connectors QuickPort Wireless Access Point (WAP) Kit ® Applications > Wireless Access Points >...
  • Page 41: Power Over Ethernet

    Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Power over Ethernet High-quality connectivity is essential for attaining the performance and reliability needed in current and future Power over Ethernet (PoE) network operations. System components should be designed to minimize temperature increases and meet industry standards for performance.
  • Page 42 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Power over Ethernet — Standards In 2013, IEEE announced a task force for creating In addition, in June 2016 the U.S. National Fire The Telecommunications Industry Association (TIA) 802.3bt, which will define PoE over four pairs...
  • Page 43 • Prevent transmission impairment due difficulty radiating heat out Leviton offers a list of tips for minimizing to structural compromise into the environment. Therefore, • Reduce long term cable degradation the cables in the middle heat up •...
  • Page 44 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Power over Ethernet — Cable and Connectivity Recommendations Reduce the Number of Cables per Bundle Separating large cable bundles into smaller bundles or avoiding tight bundles will reduce temperature rise. For example, TIA tested the temperature of a...
  • Page 45 Leviton recommends using a connector that is designed to keep the connection point between the mated connector tines and plug at a distance from the point of arcing damage. Leviton has designed the geometry of its connectors so that arcing occurs at a different area from the point of contact during data transmission.
  • Page 46 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References Power over Ethernet — Leviton Solutions In-Ceiling Bracket Plenum-Rated Surface-Mount Box Wallplates Atlas-X1™ QuickPort Connectors ® Atlas-X1 Patch Cords Pre-Terminated Trunks Patch Panels Applications > Power over Ethernet >...
  • Page 47 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References IT/AV and HDBaseT™ HDBaseT 5Play at a Glance Simultaneous transmission of 5 functions over a single category cable up to 100 m (328 ft) HDBaseT has become a key technology that enables audiovisual signal extension to high definition displays and projectors.
  • Page 48 Isolation Wrap Leviton offers a complete IT/AV System for HDBaseT applications, including HDMI extenders and Cat 6A connectivity and cable. This system can be installed, tested, and verified as a Cat 6A UTP Cable 10GBASE-T link, and is certified to HDBaseT Alliance Standards.
  • Page 49 Product Glossary and Cat 6A Installation Applications Applications Testing Overview Termination References IT/AV and HDBaseT™ — Leviton Solutions Signal Extension HDMI Cables Multi-Media Outlet System (MOS) Atlas-X1™ Patch Cords Atlas-X1 Connectors Control Systems Applications > IT/AV and HDBaseT > Leviton Solutions...
  • Page 50 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Testing Cat 6A Testing AXT Testing AXT Testing Preparation Testing Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 51 Cat 6A Testing Field testing of Cat 6A installations is much like field testing for Cat 5e and Cat 6. However, Cat 6A testing is performed to a maximum frequency of 500 MHz. In addition, Cat 6A adds several tests for alien crosstalk (AXT).
  • Page 52 Power Sum Alien Near End Crosstalk Power Sum Alien Attenuation to Crosstalk Ratio — Far End Alien crosstalk (AXT) can have a serious TIA Limit TIA Limit impact on Cat 6A cabling system Performance performance. Choose Leviton and get Performance Margin Margin excellent AXT suppression.
  • Page 53 TECH TIP: Is AXT Testing Required? • AXT tests are time-consuming: budget AXT test time into your bid Even though Leviton does not require field AXT testing for its Cat 6A • Handheld test instruments (field testers) require an additional AXT module solutions, you may still be required to perform this testing.
  • Page 54: Product Overview

    Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Product Overview Connectors Patch Panels Patch Cords Pre-Terminated Copper Trunks Signal Extension Wallplates and Housings Cable Management QuickPort Wallplates Versi-Duct ® ® QuickPort Surface-Mount Boxes OIP (Overhead Infrastructure Platform)
  • Page 55 Bulk Icons, pack of 72 ICONS-IC* ICONS-IC* (2-sided icons, 24 of each icon) Atlas-X1 Cat 6A connectors deliver the highest level of verified performance Wire Managers, bag of 10 AXUJK-BWM AXSJK-BGM and reliability, and offer simple tool-free terminations. The connectors feature...
  • Page 56: Patch Panels

    Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Patch Panels e2XHD Composite QuickPort 110-Style e2XHD — Simple termination and improved cable routing. Cassettes PATCH PANEL OPTION quickly snap in and pull out of high-density panels, making installation...
  • Page 57: Patch Cords

    Color: Yellow (Y), Red (R), Blue (L), Green (G) and Grey (S); also available in White (W), Violet (V), and Black (E) ºº Length in meters All Leviton Cat 6A patch cords are RoHS Compliant. interference (EMI/RFI). The SlimLine boot features a narrow profile for less Plenum-rated solid conductor patch cords are also available.
  • Page 58 Applications Testing Overview Termination References Pre-Terminated Copper Trunks Leviton makes it easy to configure your own copper UTP Connector UTP Connector trunks, customized for length, connector type, and more. to Plug to e2XHD Cassette With factory testing and no need for field terminations, you can reduce installation time by up to 75%.
  • Page 59 41920-CP8 Wallplate Control Panel HDMI Cables HDMI CABLES Leviton high-speed HDMI Cables with Ethernet are ideal for supporting in-wall DESCRIPTION and permanent installations. The cable is CL2-rated for in-wall installations, and HDMI Cable 41900-xxE it is flexible to accommodate common box depths while maintaining minimum...
  • Page 60 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Wallplates and Housings QuickPort and QuickPlate Wallplates QuickPort Surface-Mount Boxes ® ® In-Ceiling and In-Wall Brackets Multimedia Outlet System (MOS) Product Overview > Wallplates and Housings Leviton Network Solutions...
  • Page 61 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References QuickPort Wallplates ® WALLPLATE OPTIONS DESCRIPTION WHITE LT. ALMOND IVORY GREY BLACK BROWN 6-Port 41080-6WP 41080-6TP 41080-6IP 41080-6GP 41080-6EP 41080-6BP 4-Port 41080-4WP 41080-4TP 41080-4IP 41080-4GP 41080-4EP 41080-4BP Single Gang...
  • Page 62 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References QuickPlate Wallplates ® QuickPlate Tempo Wallplates with ID Windows QuickPlate Tempo wallplates allow for fast, one-piece installations. They feature patented rear wings that tighten the wallplate to wallboard, eliminating the need for a box or mounting brackets.
  • Page 63 (both provided) or with magnets or modular furniture brackets (sold separately). One-, two-, and four-port surface-mount boxes are plenum rated. Extended 12-Port Standard depth 4S089 boxes are best suited for use with Cat 6A cable. Surface-Mount Box 7.60" W x 5.02" D x 1.13" H...
  • Page 64 The QuickPort WAP Kit combines all the pieces necessary to install a QuickPort WAP Kit, includes In-Ceiling Bracket (49223-CBC), testable permanent link for cabling that terminates in plenum spaces. 2 Cat 6A connectors (6AUJK-RW6), Surface-Mount Box 49223-W10 The kit is ideal for Ethernet-enabled devices that mount on or above (4S089-2WP), 2 Cat 6A patch cords (AXPPP-10W) ceiling tiles, such as WAPs and cameras.
  • Page 65 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Multimedia Outlet System (MOS) MOS provides a clean and flexible system to integrate data and AV modules into one wallplate or surface-mount box. Changes are made without removing VGA PC Module...
  • Page 66: Cable Management

    Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Cable Management Versi-Duct OIP (Overhead Infrastructure Platform) ® Zone Enclosures Product Overview > Cable Management Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 67 Designer Cover, grey — 59265-5DC moves, adds, and changes. 2RU, black cover 492RU-HFO 492RU-HFR Leviton offers a wide variety of cable management solutions; for a full list please 1RU, black cover 491RU-HFO 491RU-HFR visit Leviton.com/cablemanagement Horizontal 2RU Designer Cover, grey —...
  • Page 68 Custom heights and widths available; please contact Inside Sales Patch Panel Bracket OIPAC-PPB at 800-722-2082 for more information. For assembly, floor mounting instructions, VISIO stencils, and videos go to Leviton.com/OIP. Frame Drill Template OIPDT-xxW ® 36" Wide (36), 42" Wide (42), 48" Wide (48) Product Overview >...
  • Page 69 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Zone Enclosures Zone cabling enclosures are the perfect solution for adding flexibility within an open-office architecture or data center environment. They are plenum rated with included fire-rated foam sealing kits. Ceiling enclosures are available in active and passive styles.
  • Page 70 References Cat 6A Termination Leviton has designed several exclusive features into its new Cat 6A connectors to speed termination. Read on for details of these features, other tips for a seamless installation, and for termination instructions for our 110-style panel, UTP connectors, and shielded connector.
  • Page 71 TECH TIP: Using Icons in Atlas-X1 Connectors TECH TIP: Leviton Palm Termination Tool One of the unique benefits of Leviton Atlas-X1™ connectors is the ability to add icons to the front of the connector that Use Leviton’s Palm Termination Tool to designate specific applications, such as data, voice, and AV.
  • Page 72 References 110-Style Patch Panel Termination Instructions TECH TIP: Connector Wiring Guide and Color Code Key Mount the Cat 6A 110-Style Patch Panel to a standard 19" equipment 100 Ω UTP rack or wall-mount bracket, using the provided screws. 4 Pair Twisted Pair Wire Determine which color-coded wiring scheme is desired (T568A or T568B).
  • Page 73 Management Starting with the middle two pairs (orange/white and green/white) Once the Cat 6A module has been terminated, snap the 3-port use your fingers to carefully seat and secure the wires into the IDC retention cap to the back of the connector top and bottom sides.
  • Page 74 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Atlas-X1™ UTP Connector Termination Instructions Figure A Figure B Figure C Using a cable stripper, remove 1.5 inches Line up the wire manager with the blue pair Observing pair polarity and T568A or T568B (38 mm) of cable jacket.
  • Page 75 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Atlas-X1™ UTP Connector Termination Instructions Continued Figure D Figure E Figure F Guide Pin Hole Check polarity by making sure the white Using a flush cutter, trim all pairs flush...
  • Page 76 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Atlas-X1™ Shielded Connector Termination Instructions Figure A Figure B Using an appropriate cable stripper, remove about 1.5 inches (38 mm) of cable jacket. Inspect shield foil and pairs to ensure no foil or insulation damage.
  • Page 77 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Atlas-X1™ Shielded Connector Termination Instructions Continued Figure D Figure E Figure F Figure G Guide Pin Hole Check polarity by making sure the white wire of each pair Pull drain wire into drain wire capture notch and trim flush will be closest to the guide pinhole in the face of the wire with flush cutter.
  • Page 78 ® Figure A Remove about 3" (76 mm) of cable jacket and center spline (stiff plastic separator inside Cat 6A cable). T568A or T568B Determine whether to use wiring scheme T568A or T568B. Note: the associated color codes and connector pin number on the label located between the IDC connector slots (Figure A).
  • Page 79 Place the Cone of Silence over the terminated wires for secure ® connection and exceptional Cat 6A performance (Figure D). Use the punch down puck to terminate the jack first, then install into a patch panel or wallplate. Termination >...
  • Page 80 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary References Glossary and References Leviton Network Solutions (800) 722 2082 +1 (425) 486 2222 leviton.com/ns...
  • Page 81 500 opposite of gain and is measured in decibels (dB). occur before a cable may sustain damage or MHz. Cat 6A is designed to support 10GBASE-T or 10 increased attenuation. Gigabit Ethernet up to distances of 100 m (328 ft).
  • Page 82 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Channel In the horizontal cabling portion of a Conductor Any substance, usually a wire or cable, Data Center (DC) A data center is a facility used structured cabling system, the channel contains that can carry an electrical current.
  • Page 83 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Ethernet Leading local area network (LAN) FCC (Federal Communications Commission) Gigabit When used to describe data transfer protocol used for connecting computers, printers, FCC is an independent United States government rates, Gigabit refers to 10 to the 9th power agency.
  • Page 84 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Interconnect IDC (insulation displacement connection) IEEE 802.3an A standard for 10GBASE-T A circuit administration point, other An IDC allows the termination of a conductor released in 2006 to provide 10 gigabit per second...
  • Page 85 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Patching Mbps (megabits per second) One million bits NEXT (near-end crosstalk) Electrical noise A means of connecting circuits via cords per second. coupled from one pair of wires to another within and connectors that can be easily disconnected and a multi-pair cable.
  • Page 86 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Permanent Link In the horizontal cabling portion Premises Telephony term for the space Return Loss (RL) A measure of the similarity of the of a structured cabling system, the permanent link...
  • Page 87 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References Glossary » » » Structured Cabling System A structured cabling TIA (Telecommunications Industry Association) UTP (unshielded twisted pair) Also classified system (SCS) is defined as the complete collective The TIA is a trade organization of manufacturers...
  • Page 88 Product Glossary and Cat 6A Installation Applications Testing Overview Termination References References This guide has been developed consistent with all known applicable cabling practices as defined by the following: ANSI/TIA-607-C ANSI/TIA-606-C National Electrical Safety Code (NESC) Generic Telecommunications Bonding and Grounding...
  • Page 89 And we stand behind every product Africa China brand-rex.com +971 (4) 886 4722 +852 2774 9876 Brand-Rex Limited is a subsidiary of Leviton Mfg. Co., Inc lmeinfo@leviton.com infochina@leviton.com and end-to-end system — delivering the Customer Service Asia / Pacific...