Download Print this page

Contech DownSpout StormFilter Operation And Maintenance page 2

Single stage units

Advertisement

Maintenance Guidelines 
The filter cartridges contained in the DSF 
are easily removed and replaced during 
maintenance activities according to the 
following guidelines: 
1.  Establish a safe working area as per 
typical catch basin service activity. 
2.  Remove lid. 
3.  Turn cartridge(s) counter­clockwise to 
disconnect from pipe manifold. 
4.  Remove 4" center cap from cartridge 
and replace with lifting cap. 
5.  Remove cartridge(s) from cartridge 
chamber by hand or with vactor truck 
boom. 
6.  Remove accumulated sediment via 
vactor truck (min. clearance 13" x 24"). 
7.  Rinse interior of chamber and vactor 
remaining water and sediment. 
8.  Install fresh cartridge(s) threading 
clockwise to pipe manifold. 
9.  Replace lid. 
Return original cartridges to 
10. 
CONTECH Stormwater 
Solutions for cleaning and 
media disposal. 
©2006 CONTECH Stormwater Solutions 
contechstormwater.com 
Toll­free: 800.548.4667 
Single Stage DownSpout StormFilter Operation and Maintenance Guidelines 
Media may be removed from the filter 
cartridges using the vactor truck before the 
cartridges are removed from the catch 
basin structure.  Empty cartridges can be 
easily removed from the catch basin 
structure by hand.  Empty cartridges should 
be reassembled and returned to CONTECH 
Stormwater Solutions, as appropriate. 
Note: Customer is responsible for 
disposing of media in accordance with 
applicable regulations. 
Materials required include a lifting cap, 
vactor truck, and fresh filter cartridges. 
Contact CONTECH Stormwater Solutions 
for specifications and availability of the 
lifting cap.  The owner may refresh spent 
cartridges.  Refreshed cartridges are also 
available from CONTECH Stormwater 
Solutions on an exchange basis.  Contact 
the maintenance department of CONTECH 
Stormwater Solutions at (800) 548­4667 for 
more information. 
Maintenance is estimated at 24 minutes of 
site time.  For units with more than one 
cartridge, add approximately 5 minutes for 
each additional cartridge.  Add travel time 
as required.
2 of 2 