Download Print this page

Saito OB-1 Instruction Manual page 2

Advertisement

Preparation
(Some pictures show V-2&OB-1 Unit , but operation is just the same)
A. Fixing the smokestack
1. Fix the smokestack to the boiler with a fixation
screw. Once fixed, it doesn t need to be removed.
3. Remove the overflow cap as well.
5. After filling up water, securely install two caps to their
original position.
(Too much tightening makes Caps and O-rings worn.)
C. Preparation(Feeding Oils for lubrication)
6. Remove the oiler cap.
B. Preparation (Filling up water)
2. Remove the safe valve cap.
4. Insert the infundibulum deep into the port of safe
valve and fill up water, till water comes out from the
port of overflow cap. It can be filled about 100cc from
vacant. You can cover under the port to wipe out
overflowed water. Using pure water is the best bur
you can use tap water as long as it s clean. DO NOT
use water includes lots of rust or chlorine, or hard
water.
Unless filling water sufficiently, it may cause boil-dry
burning that results boiler broken.
Water flows
even if it hasn t fulfilled yet.
Insert
Narrow
7. Full fill steam oil (blue liquid) up to the oiler and
reinstall the oiler cap.
Filling any different oil to the oiler causes engine
break. It can be coagulated inside the cylinders.
-2-
Water can be
fulfilled properly.
Insert
Deep

Advertisement

loading

This manual is also suitable for:

Oe-1