Endress+Hauser Field Xpert SMT70 Operating Instructions Manual
Endress+Hauser Field Xpert SMT70 Operating Instructions Manual

Endress+Hauser Field Xpert SMT70 Operating Instructions Manual

Universal, high-performance tablet pc for device configuration in ex zone 2 and non-ex areas
Hide thumbs Also See for Field Xpert SMT70:

Advertisement

BA01709S/04/EN/02.18
71405618
2018-07-27
Products
Operating Instructions
Field Xpert SMT70
Universal, high-performance tablet PC for device
configuration in Ex Zone 2 and non-Ex areas
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Field Xpert SMT70 and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser Field Xpert SMT70

  • Page 1 Products Solutions Services BA01709S/04/EN/02.18 71405618 2018-07-27 Operating Instructions Field Xpert SMT70 Universal, high-performance tablet PC for device configuration in Ex Zone 2 and non-Ex areas...
  • Page 2 Change history Field Xpert SMT70 Change history Product version Operating Instructions Changes Comments 1.00.xx BA01709S/04/EN/01.17 1.02.xx BA01709S/04/EN/02.18 New chapter 8.5 HART via PROFINET via Fieldgate PAM SFG600 Endress+Hauser...
  • Page 3: Table Of Contents

    Field Xpert SMT70 Table of contents Table of contents About this document ... 4 Establishing a connection to the device ......21 Document function .
  • Page 4: About This Document

    About this document Field Xpert SMT70 About this document Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 5 Field Xpert SMT70 About this document Symbol Meaning Notice or individual step to be observed. … Series of steps. Result of a step. Help in the event of a problem. Visual inspection. 1.2.3 Field Xpert symbols Symbol Meaning Switch tablet on and off.
  • Page 6: Acronyms Used

    About this document Field Xpert SMT70 Symbol Meaning Update Expand information. Collapse information. Connect automatically Connect with wizard (manual connection) Connect with Remote Wizard Acronyms used Acronyms Explanation Dynamic Frequency Selection Federal Communications Commission High frequency [RF = radio frequency]...
  • Page 7: Basic Safety Instructions

    Field Xpert SMT70 Basic safety instructions HART®, WirelessHART® is the registered trademark of the FieldComm Group, Austin, TX 78759, USA. PROFIBUS® is a registered trademark of the PROFIBUS User Organization, Karlsruhe/ Germany. Modbus is the registered trademark of Modicon, Incorporated.
  • Page 8: Operational Safety

    Modifications to the device Unauthorized modifications to the device are not permitted and can lead to unforeseeable dangers: ‣ If, despite this, modifications are required, consult with Endress+Hauser. Repair To ensure continued operational safety and reliability: ‣ Carry out repairs on the device only if they are expressly permitted.
  • Page 9 Field Xpert SMT70 Product description The tablet PC' s good ergonomic features also protect workers' health, keeping physical strain to a minimum. With the increasing popularity of 4G/LTE connectivity in hazardous areas, the tablet PC ensures swift and seamless access to data. However, in situations where not even WLAN is available, the optional docking station with an Ethernet interface gives the tablet PC the necessary flexibility to link into existing network infrastructures.
  • Page 10 Product description Field Xpert SMT70 Component Description Program button Go to user-defined program Front camera For video recordings (e.g. at video conferences) Ambient light sensor Measures the current ambient lighting conditions Microphone To record ambient sounds Function key The key function can be assigned via the "Quick Menu"...
  • Page 11 Field Xpert SMT70 Product description  2 Rear view of tablet PC Barcode scanner Camera LED flash Camera Battery compartment Button to unlock the battery compartment Loudspeaker Combined audio jack 2 x USB 3.0 Memory card slot for Micro SD memory cards...
  • Page 12: Product Design

    Product description Field Xpert SMT70 Component Description 2 x USB 3.0 For connecting USB 3.0 peripheral devices. WARNING The use of the USB ports in the hazardous area is not permitted and can cause an explosion. ‣ In the hazardous area, always use an Ex-tablet with the MACTek VIATOR Bluetooth HART modem.
  • Page 13: Licence Model

    The device configuration software is already installed on the tablet PC upon delivery. To use the software as designated, the software must be activated. A user account is required in the Endress+Hauser software portal for this purpose. This account might first need to be created via the "Create account" function.
  • Page 14: Incoming Acceptance And Product Identification

    The device may not be put into operation if the contents are found to be damaged beforehand. In this case, please contact your Endress+Hauser Sales Center: www.addresses.endress.com Return the device to Endress+Hauser in the original packaging where possible. Scope of delivery • Field Xpert SMT70 tablet PC with handle •...
  • Page 15: Product Identification

    Manufacturer model number Manufacturer technical information Manufacturer serial number 4.2.2 Manufacturer address Ecom Instruments GmbH, D-97959 Assamstadt, Germany is responsible for the tablet hardware and produces it exclusively for Endress+Hauser. Endress+Hauser Process Solutions AG Christoph Merian-Ring 12 CH-4153 Reinach Switzerland www.endress.com...
  • Page 16: Storage And Transport

    Installation Field Xpert SMT70 Storage and transport Always use the original packaging when transporting the product. 4.3.1 Storage temperature –20 to 60 °C (–4 to 140 °F) Installation System requirements The software is already installed on the tablet PC upon delivery.
  • Page 17: Removing The Software

    Field Xpert SMT70 Software operation Removing the software The device configuration software may not be uninstalled. Software operation Avoid damage to the housing and components: ‣ Always place the device on a stable surface. ‣ Do not cover the ventilation opening, or block it by other objects.
  • Page 18: Switching Off The Tablet Pc

    Commissioning Field Xpert SMT70 The tablet PC shuts down. Do not disconnect the power source until the tablet PC is switched off completely. Switching off the tablet PC ‣ Press and hold the button until the power LED flashes. The tablet PC is in sleep mode.
  • Page 19: Inserting The Battery

    Field Xpert SMT70 Commissioning Inserting the battery Insert the battery in the battery compartment. Press down until the battery clicks into place. Slide the battery lock into the "Locked" position. The battery is inserted. Endress+Hauser...
  • Page 20: Charging The Battery

    Operation Field Xpert SMT70 Charging the battery Due to transport safety regulations, the lithium ion battery is not fully charged when purchased. The battery must be inserted. Connect the AC adapter to the DC socket of the tablet PC. Connect the AC adapter to the power cable.
  • Page 21: How To Start

    The user must accept the terms of use the first time the device configuration software is started. ‣ Double-click Field Xpert SMT70 on the start screen.  The device configuration software starts. Establishing a connection to the device A connection can be established in either of two ways: •...
  • Page 22 The following modems/interfaces are supported by the tablet PC: Communication protocol Connection Modems/interfaces HART Endress+Hauser Commubox FXA195 4 to 20 mA MACTek Bluetooth modem 4 to 20 mA Memograph RSG45 (4 to 20 mA) MACTek USB modem (4 to 20 mA) Softing Mobilink...
  • Page 23 Field Xpert SMT70 Operation Communication protocol Connection Modems/interfaces Modbus Modbus serial WirelessHART WirelessHART adapter SWA70 WirelessHART Fieldgate SWG70 Endress+Hauser service interfaces Commubox FXA291 CDI Commubox FXA291 IPC, ISS, PCP Commubox FXA193 IPC, ISS TXU10 V2 CDI TXU10 V2 PCP TXU10 V1 PCP, CDI...
  • Page 24 Operation Field Xpert SMT70 "Automatic" connection ‣ Click the icon.  The device configuration software establishes a connection to the connected device. Endress+Hauser...
  • Page 25 Field Xpert SMT70 Operation "Wizard" connection Click the icon.  An overview of all the protocols available opens. Endress+Hauser...
  • Page 26: Information And Software Settings

    Operation Field Xpert SMT70 Select a communication protocol.  An overview of all the modems available opens. Select a modem.  The device can now be configured. Information and software settings ‣ Click the icon in the main menu.  The overview of all the information and settings opens.
  • Page 27 Field Xpert SMT70 Operation The offline view of the device driver opens. This function is only possible if the device driver supports the offline view. If other device drivers (DTMs) are required, they can be installed additionally. After an automatic or manual update, these drivers appear in the DTM catalog.
  • Page 28 Operation Field Xpert SMT70 8.3.4 Managing reports Click the Manage reports tab.  The overview with the "Managed saved device reports" folder opens. Click the "Managed saved device reports" folder.  The overview of all the saved device reports opens.
  • Page 29 Field Xpert SMT70 Operation 8.3.6 Settings Language Click the Settings tab.  The Language tab with an overview of all the languages available opens. Click the desired language. Click the icon.  The device configuration software closes. Restart the device configuration software.
  • Page 30: Additional Information About The Software

    Operation Field Xpert SMT70 Additional information about the software ‣ Click the icon.  The overview of all the additional information opens. 8.4.1 License ‣ Click the License tab.  The dialog box with the licensing information opens. 8.4.2 Update ‣...
  • Page 31: Fieldgate Pam Sfg600 Hart Via

    Operation 8.4.3 EULA ‣ Click the EULA tab.  The window with the Endress+Hauser Terms and Licensing Conditions opens. 8.4.4 About This tab contains information about the software currently installed, the manufacturer and the software source text. Click the About tab.
  • Page 32: Diagnostics And Troubleshooting

    Corrective action The device The device configuration software must be reinstalled: configuration software This PC\Local disk (C:)\Restore\Field Xpert SMT70\FieldCareSFE300Setup.exe has been uninstalled.  The device configuration software can only be reinstalled if it is activated and the service period of one year (starting with the activation of the software) has not yet expired.
  • Page 33: Maintenance

    Field Xpert SMT70 Maintenance Maintenance 10.1 Replacing the battery DANGER Incorrect replacement of the battery can cause an explosion. ‣ Always replace the battery with an identical battery or an equivalent type of battery recommended by the manufacturer. The battery capacity gradually diminishes over time, depending on how the battery is used.
  • Page 34: Cleaning

    NOTICE Never disassemble or repair the device yourself, as this will render the warranty invalid. ‣ If the device is in need of repair, always contact your Endress+Hauser Sales Center: www.addresses.endress.com 11.2 Spare parts Detailed information about spare parts is available from the Endress+Hauser Sales Center: www.addresses.endress.com...
  • Page 35: Return

    As an ISO-certified company and also due to legal regulations, Endress+Hauser is obliged to follow certain procedures when handling any returned products. To ensure safe, swift and professional device returns, please refer to the procedure and conditions for returning devices provided on the Endress+Hauser website http://www.endress.com/support/return-material...
  • Page 36: Appendix

    Appendix Field Xpert SMT70 Appendix 14.1 Federal Communication Commission (FCC) This device has been tested and complies with the limit values for Class B digital devices in accordance with Part 15 of the FCC regulations. These limit values ensure adequate protection against electromagnetic interference when operating in residential areas.
  • Page 37: Class 1 Laser Product

    Field Xpert SMT70 Appendix denoting minor mechanical options, system configuration options and/or safety extra low voltage secondary circuit options. Conditions of Safe Use: Connection to or from this device, which enters or leaves the system enclosure, must be completely restricted in Class I, Division 2 Hazardous Locations.
  • Page 40 www.addresses.endress.com...

Table of Contents