Problem
There is too much frost and
ice.
The compressor does not
start immediately after
pressing the "Frostmatic" or
"Coolmatic", or after chang-
ing the temperature.
Water flows on the rear
plate of the refrigerator.
Water flows inside the refrig-
erator.
Water flows on the floor.
Temperature cannot be set.
dEMo appears on the dis-
play.
The temperature in the ap-
pliance is too low/too high.
Possible cause
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
The water drainage plug is
not correctly positioned.
Temperature is set incor-
rectly.
This is normal, no error has
occurred.
During the automatic de-
frosting process, frost
melts on the rear plate.
Food products prevent the
water to flow into the wa-
ter collector.
The water outlet is clog-
ged.
The melting water outlet is
not connected to the
evaporative tray above the
compressor.
The "Frostmatic function"
or "Coolmatic function" is
switched on.
The appliance is in demon-
stration mode.
The temperature regulator
is not set correctly.
The door is not closed cor-
rectly.
ENGLISH
Solution
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Refer to "Operation" .
The compressor starts after a
period of time.
This is correct.
Make sure that food products
do not touch the rear plate.
Clean the water outlet.
Attach the melting water out-
let to the evaporative tray.
Switch off "Frostmatic func-
tion" or "Coolmatic function"
manually, or wait until the
function resets automatically
to set the temperature. Refer
to "Frostmatic function" or
"Coolmatic function".
Keep the OK pressed for ap-
proximately 10 seconds until a
long sound is heard and dis-
play shuts off for a short time.
Set a higher/lower tempera-
ture.
Refer to "Closing the door".