Specifications - Craftsman 390.304692 Owner's Manual

Submersible sump pump
Hide thumbs Also See for 390.304692:
Table of Contents

Advertisement

SERVICE
/ SPECIFICATIONS
General
I AWARNINGIRisk
of electric
shock.
When
servicing
pump
always
disconnect
power
to electrical
outlet
and
remove
pump
electric
cord
from
outlet.
I. If pump
does not opcnltc:
a. Check
for loosc plug at electric
outlet.
b. Check
for blown
fuses or tripped
circuit
breakers
at
fuse box/circuit
breaker
box.
c. Be sure
nothing
interl_zrcs
with
action
of automatic
float switch.
d. lfa, b, and c above check OK, plug in a light that you
know works. If it lights, take your pump to Sears for
service. If it doesn't light, the electrical circuit is faulty;
consult a licensed electrician.
2. Pump starts, but blows fuses/trips circuit breakers:
After disconnecting
power to pump, remove the screen
and shield from the bottom of the pump and make sure
that the impeller turns freely. Remove any debris ob-
structing
impeller.
If pump still does not operate
cor-
rectly, return it to your nearest Sears Service Department
for repairs.
3. Pump runs, but does not empty sump:
a. Clean pump intake screen.
b. Water may be entering sump faster than the pump can
discharge it.
c. Be sure vertical distance from pump discharge outlet
to discharge
pipe outlet does not exceed maximum
vertical pumping
distance shown in "Specifications,"
below.
d. Be sure discharge pipe is not plugged or frozen.
TEATHERED
SWITCH
REPLACEMENT
NOTICE: Teathcred float must bc able to swing through its
complete
arc without
interference from sidewall of sun]p.
l_hunl_ing or ally otiacr ohjcct.
I
Rcn]<)ve
ptln)p
power cord fiom
s\\itch
plug
2. I{cmove tether clamp screw and slide cord from clamp.
3. Insert new cord in tether clamp. Put the clamp at the
same distance from the float that it was on the old switch.
4. Tighten tether clamp screw.
5. Check sump pump operation by filling sump with water
and observing operation through one complete cycle.
[_ik
WARNING
]Failure to check installation
with water
in sump can lead to improper operation,
premature
pump
failure and flooding.
Stock
Maximum
Number
HP
Amps
30469
1/3
13.0
3050
1/2
7.6
30479
1/3
9.8
30579
112
12.0
Dimensions in inches (mm)
SPECIFICATIONS
GPM(L/rain.) at VerticalPumpingDistance in Feet(M)
Height
11-1/2" (292)
11-1/2" (292)
11-1/2" (292)
11-1/2" (292)
5' (1.6)
10' (3)
15' (4.6)
50(189)
41 (155)
28(106)
61 (231)
56(212)
50(189)
48(182)
39(148)
29(110)
62 (235)
53 (200)
46 (174)
Length
9" (229)
9" (229)
9-3/4" (248)
9-3/4" (248)
Width
6-1/2" (165)
6-1/2" (165)
7-5/16" (186)
7-5/16" (186)
! 20' (6.1)
25' (7.6)
3 (11.4)
-
46(174)
43(163)
16(61)
-
38 (144)
26 (98)

Advertisement

Table of Contents
loading

This manual is also suitable for:

390.305001390.304790390.305790

Table of Contents