P3000 STANDARD FRAME & LID INSTALLATION
STEP 1
Install horizontal joist and gang box
To ensure a comfortable working height it is recommended that the
top of the gang box be installed 36" from the ground using a level.
Note: Leave at least a 2" buffer zone around base to keep clear from
perpendicular walls.
STEP 3
Install base over top of the gang box using No. 8 flat
head screws
Install single screw in corner flange, level, then secure with
additional screws.
FOR MORE INFORMATION CONTACT:
1.604.881.7875
1.604.881.7835
T
F
www.primex.com
452-3113
PRODUCT
MODEL CODE
WARNING
• DO NOT stretch enclosure walls or lid won't seat properly.
• DO NOT overtighten mounting screws.
• DO NOT use mounting screws larger than #8.
Note: Adhere to your local electrical code when installing all cabling.
STEP 2
Remove knock outs
Prior to installation, remove the knockouts for the conduit and
electrical box using a flush cutter tool.
STEP 4
Connect power and install electrical outlet faceplate
At this stage, connect conduit for outgoing and incoming services and
secure with Primex conduit adapters.