PYE PPAC15 User Manual

PYE PPAC15 User Manual

15,000 btu portable air conditioner

Advertisement

15,000 BTU PORTABLE AIR
CONDITIONER
Model: PPAC15
User Manual
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PPAC15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PYE PPAC15

  • Page 1 15,000 BTU PORTABLE AIR CONDITIONER Model: PPAC15 User Manual READ AND SAVE THESE INSTRUCTIONS...
  • Page 2: Table Of Contents

    CONTENTS IMPORTANT SAFEGUARDS……………………………………………….2 INSTALLATION……………………………………………………………….4 IDENTIFICATION……………………………………………………………..6 CONTROL PANEL……………..……………………………………………..7 REMOTE CONTROL……………………………………………………..8 OPERATION…………………………………………………………………..9 WATER DRAINAGE…………………………………………………………10 MAINTENANCE……………………………………………………………..11 TROUBLESHOOTING……………………………………………………...12...
  • Page 3: Important Safeguards

    Dear Customer, Thank you for purchasing our PYE Portable Air Conditioner. Please be sure to read this user manual carefully before using it. BEFORE FIRST USE Read and follow the instructions in this user manual even if you feel you are familiar with the product, and find a place to keep it handy for future reference.
  • Page 4 • The air conditioning unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor; in case of any doubt after moving the appliance we suggest to wait for at least 24 hours before you start the air-conditioning unit. •...
  • Page 5: Installation

    INSTALLATION Location: • Install the unit on a flat, dry surface. • Leave at least 50cm of space all around the unit. Temporary method 1. Fix the end of the exhaust duct to the exhaust terminal of the unit. 2. Half-open the window and let the air outlet duct through. The window slider kit has been designed to fit most standard vertical and horizontal windows.
  • Page 6 Incorrect mounting 1. The bend of the exhaust pipe is very important. 2. Incorrect mounting can contribute to cooling inefficiency. Take care to prevent any sharp bows or bends in the exhaust. The exhaust air must be able to flow freely.
  • Page 7: Identification

    IDENTIFICATION Front 1. Control panel 2. Air outlet 3. Signal receptor 4. Adjustable air flow 5. Transport handle Back 6. Castor 7. Air inlet 8. Drain port (used when there is continuous drainage or in dry mode) 9. Power cord 10.
  • Page 8: Control Panel

    CONTROL PANEL 1. ON/OFF button: press this button to turn On/Off the unit. 2. MODE button: press this button to select Cool, Dry or Fan mode. 3. SPEED button: press this button to select high, middle or low fan speed. 4.
  • Page 9: Remote Control

    REMOTE CONTROL 1. High fan speed button 2. Middle fan speed button 3. Low fan speed button 4. Swing button 5. Timer button 6. Up button 7. Down button 8. Cool mode button 9. Dry mode button 11. Celsius and Fahrenheit button 12.
  • Page 10: Operation

    OPERATION Cooling mode • Press the MODE button (or Cool button) to choose Cool mode, the LCD will display • Press UP or DOWN button to set room temperature between 17° to 30°. • Press SPEED button (or Low/Mid/High button) to select low, middle or high fan speed. The LCD will display , or accordingly.
  • Page 11: Water Drainage

    WATER DRAINAGE This product has a self-evaporative system. The water will be recycled to cool the condenser. This not only improves cooling efficiency, but also saves energy. • When in Cool or Fan mode, there’s no need for water drainage. •...
  • Page 12: Maintenance

    MAINTENANCE Note: Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock. Cleaning • Power off and unplug the unit before any cleaning. • Clean the housing with a soft damp cloth. Do not use chemical solvent (such as benzene, alcohol, gasoline).
  • Page 13: Troubleshooting

    The batteries are drained. Replace the batteries. Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Then contact a qualified electrician. SPECIFICATIONS Model: PPAC15 Permissible excessive operating pressure (Suction/Discharge): 1.0MPa/3.5MPa Cooling capacity: 4.4kW Maximux allowable pressure (Low pressure side/High pressure side): 1.5MPa/5.5MPa...

Table of Contents

Save PDF