Sunnen GR-2245 Operating Instructions

Retractable dial bore gauge

Advertisement

http://www.sunnen.com
SUNNEN
NOTE: Metric dimensions shown in these instructions are conversion equivalents only . . . items are not
graduated in metric dimensions unless specifically identified as Metric Models.

HOW TO USE

1. Select correct Gage Point (see Table1).
2. Screw correct range Gage Point (G) into gaging
head (see Figure 1).
3. Set gage to desired size, using a ring gage,
micrometer, or Sunnen CF-1000 Dial Bore Gage
Setting Fixture. Set desired size by turning Gage
Point in or out.
NOTE: If gage nest on your CF-1000 Setting Fixture
has vertical dowel pins, you will have to replace it
with a CF-140 Nest Kit (horizontal dowel pins) in
order to use the CF-1000 with the GR-2245 Gage.
TABLE 1
USE GAGE POINT NO.
1
2
3
4
5
6
7 + 2
7 + 3
7 + 4
7 + 5
7 + 6
FIGURE 1
FIGURE 2

OPERATING INSTRUCTIONS

®
GR-2245 RETRACTABLE DIAL BORE GAGE
DIAMETER RANGE: 2 – 6in. (50 - 150mm)
FOR DIAMETER RANGE
INCHES
mm
2.000 - 2.375
50 - 60
2.375 - 2.750
60 - 70
2.750 - 3.125
70 - 79
3.125 - 3.500
79 - 89
3.500 - 3.875
89 - 98
3.875 - 4.250
98 - 108
4.250 - 4.625
108 - 117
4.625 - 5.000
117 - 127
5.000 - 5.375
127 - 137
5.375 - 5.750
137 - 146
5.750 - 6.000
146 - 150
for
4. Lock Gage Point (G) with Locking Nut (C),
using wrench furnished.
5. Recheck "0" setting; reset to "0" if necessary by
loosening bezel screw, rotating indicator dial face,
and tightening bezel screw.
6. Insert gage into bore to be measured and rock as
shown at "E" to obtain minimum reading.
7. To retract centralizer points and indicator point
squeeze Retract Lever (see Figure 2).

HOW TO ADJUST:

Adjust Centralizer Points to Bore Size - If
Points don't touch walls of bore, or if they exert too
much pressure on walls, adjust as follows:
1. Insert gaging head approximately 3/4in. (20 mm)
into bore being measured.
2. Insert 5/64in. Hex Wrench into Centralizer Stop
Adjustment. Rotate Wrench to retract or expand
Points until they barely contact walls of bore (see
Figure 3).
3. Slide gaging head in and out of bore several
times to check adjustment.
NOTE: The closer Centralizer Points are set to bore
size, the easier it will be to insert gage into bore.
Adjust Worn Centralizer Points - When
Centralizer Points must be adjusted because of
excessive wear, be sure to adjust both Points at
same time. Insert 3/32in. Hex Wrench through both
I-GR-2245D
FIGURE 3
FIGURE 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GR-2245 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sunnen GR-2245

  • Page 1: Operating Instructions

    CF-140 Nest Kit (horizontal dowel pins) in Points don't touch walls of bore, or if they exert too order to use the CF-1000 with the GR-2245 Gage. much pressure on walls, adjust as follows: 1. Insert gaging head approximately 3/4in. (20 mm) TABLE 1 into bore being measured.
  • Page 2 Ball Tool to prevent damage to gage when reinstalling Ball (see Figure 9). FIGURE 5 FIGURE 9 “SUNNEN AND THE SUNNEN LOGO ARE REGISTERED TRADEMARKS OF SUNNEN PRODUCTS COMPANY.” SUNNEN PRODUCTS COMPANY Sunnen ® reserves the right to change or revise specifications and product design in connection with any feature of our products contained herein.

Table of Contents