Gsm wireless communication channel control panel (34 pages)
Summary of Contents for Ortus Lind-EM
Page 1
Attention! Reliability and life of the product are provided not only by the quality of product itself, but also by the compliance with operating modes and conditions, therefore, meeting the requirements of this document is mandatory. “Lind-EM” Proximity Identification Card Reader Operating Manual Product Compatibility Table Control Panel “Lun-11”, “Lun-11 mod.2”,...
1. Purpose “Lind-EM” Proximity Identification Card Reader (hereinafter referred to as “reader”) is designed to control “Lun-11”, “Lun-11 mod.2”, “Lun-9T” and “Lun-7T” Control Panel and display their status. The reader operates with proximity cards/keyfobs of “EM-Marine” standard on a frequency of 125 kHz at the distance of 3...8 cm.
There are up to 14 readers may connected to the "Lun-11" / "Lun-11 mod.2» Control Panel and only one reader – to the "Lun-9T", "Lun-7T" Control Panels. Control Panel's type and reader's address on the bus shall be set for correct operation using DIP-switches located inside the reader in accordance with Table 2.
4. Arming 1. You should tightly close all room doors and windows to arming Control Panel. Attention! You can't to arm some group if at least one detector (zone) in this group is at the "alarm" state. If reader is within range of the optical sensor, you should stop moving for a few seconds before PIR goes to normal state.
5. Disarming 1. You should enter the armed room through the front door. There are a time out since opening the front door to an alarm on (time out configurable). 2. You should go to the reader and bring legal identification card/fob to him before time out end.
7. Maintenance This product does not require any maintenance. 8. Operating conditions The device shall be used at the temperature of –5°С to +40°С and relative humidity of 5% to 85%. 9. Storage 1. Product storage in terms of the climate impact shall be under conditions 2 according to GOST 15150.
Attention! Adherence to this connection diagram is mandatory. Failure to comply with this requirement can lead to breakdown of the device, and consequently, to impossibility of performance of the warranty liabilities. Figure 2. Diagram of connection “Lind-EM” ICD to “Lun-11” Control Panel АДМА.425713.005 РЭ Rev. en_3...
Page 9
Figure 3. Diagram of connection “Lind-EM” ICD to “Lun-7T”/”Lun-73T” Control Panel АДМА.425713.005 РЭ Rev. en_3...
Page 10
Figure 4. Diagram of connection “Lind-EM” ICD to “Lun-9T”/”Lun-9P” Control Panel АДМА.425713.005 РЭ Rev. en_3...
● equipment with external defects (obvious mechanical damages, cracks, chips on the housing and inside the ● device, broken antenna or connector pins). Manufacturer: ORTUS Group 5624 California st, San Francisco, CA 94121, USA Tel.:+1 650 240 27 62 mail: info@ortus.io...
Need help?
Do you have a question about the Lind-EM and is the answer not in the manual?
Questions and answers