CHANGING YOUR
CHANNEL SETTINGS
Any connected utilities need to be connected
to a 'Turned On' channel. Here is a quick walk
through a channel set up.
Navigate to this screen via NETTHINGS,
CONFIGURATION then CHANNELS
CHANGING YOUR
PULSE SETTINGS
When monitoring utilities via pulse you
will have to adjust the scale to match
the pulse of the connected equipment.
Navigate to this screen via NETTHINGS,
CONFIGURATION then SETTINGS and
select PULSE CONFIGURATION in
APPLICATION OPTIONS
IMPORTANT
Whilst NetThings takes all reasonably practical steps
to design and manufacture its products to comply with the
requirements of the Health and Safety at Work Act 1974, all
products must be properly used and purchasers are reminded
that their obligations under the Act are to ensure that the
installation and operation of such products at a place of work
should be safe and without risk to them. Do not place the product
where it may be affected by dust, moisture, adverse temperature,
radio interference or be subject to physical damage.
Do not insert any objects into the Energy Manager or Display.
CAUTION Do not connect or disconnect CTs with the device
powered up as terminals will be at mains potential!
This information is for reference only. Accuracy may vary
depending on the type of connection and wiring system used.
CARE AND MAINTENANCE: The NetThings Energy Manager
or Display require no regular maintenance. Do not spray with
water or any cleaning products.
WHAT'S IN THE BOX?
1 x NT Measurement Unit, 1 x 5" Table display,
1 x aluminium tamper free wall mount, 1 x display power
supply, 1 x CT 16mm and 2 x pulse cable free end 10m
plus User and Installation guide.
DECLARATION OF CONFORMITY This product conforms to: ETSI EN 301 489- 1 V1.4.1 (2002- 08) IEC 61643, 61326, 61010, 60529. NetThings Limited, 14 New Mart Road, Edinburgh EH14 1RL
NetThings policy is one of continuous improvement and development. The right to change specification and appearance without prior notice is reserved. Document Number 200SM035 Rev.1.2.
Select the channel that is to be configured.
Select the type of pulse you want to configure here first.
PRODUCT DATA
Name of Manufacturer
Unique reference number (model number)
Purpose of product (Energy Manager)
Dimensions
Operating temperature range
Enclosure protection
Level of protection from electric shock
Case material V0 rating
Supply Voltage
Max power in watts
Power Supply Frequency Hz
WiFi IEE 802.11 Frequency Band
Type of Memory & Data Storage Capacity
Power supply for display
Number of monitored channels
CT Current Transformer related measurements (16mm/24mm)
Real-time, instantaneous Measurements
Continued Utility Measurements
WiFi Security
Change the channel type so that the icon is correct.
The channel name can be changed to represent
what is being monitored.
Indicate what the channel usage will be.
The Monthly balance can be left at zero.
Select the tariff that suits the utility being monitored.
If on channels 1 to 3 select the correct CT (default is
CT16) If on pulse channels 4 to 6 select pulse value.
Save your changes.
This field doesn't need changed.
Input the correct pulse value here.
Change this to match the correct unit value of energy.
This field doesn't need changed.
Save your changes.
NetThings Limited
NT01:00:00
Monitoring building energy consumption
165mm x 95mm x 52mm
0°C to 40°C
IP 20
Double insulation
Rated fire retardant
220-240V AC
7W
50-60 Hz
EEE 802.11 BG 2.4 GHz
Internal-4Gb storage greater than 2 years External-microSD card slot for downloading data
12W Switching Power Supply: I/P 90-264VAC unterminated wire for
spur connection. O/P USB Connection DC 5V. 82.5mm x 40mm x 29mm
Up to 6: Max of 3 x Electricity via CTs & 3 x any pulse enabled meter
Kilowatt and kilowatt/hour kW and kW/h
Energy units consumed £/h (gas, water, electricity, heat, cooling, solar power)
Historical total energy consumed in currency and kW/h. Carbon CO2
WiFi Protected Access (WPA) security protocol and certification program