8700 – 8701 TITANIUM

5. CAM

5.1
Set the CAM configurations for the Titanium (CAM > CAM 1-2)
19.
CAM settings
o Type: Defines type of CAM module
Select low-speed (default) for legacy CAM module that can run up
to 50 MBps
Select high-speed for second generation CAM module that can
run up to 100 MBps
o Watchdog: The watchdog monitors the scrambling status of all services
going through the CAM. In case one or more services are no longer
descrambled, the watchdog will proceed to the reset of the CAM module
to try to restore the descrambling of the service(s). Important: Activate
this feature only once all services are properly descrambled by the CAM
module.
o Enable: Click ENABLE to activate the CAM (default). Press APPLY to
confirm the parameters.
20.
Reference Transponder
o Reference Transponder: It is necessary to enable and select a reference
transponder in the CAM menu (for each CAM individually). The CAM
module needs authorization to descramble services. Select the reference
transponder with authorization information for each CAM individually.
o Press APPLY to confirm the parameters.
21.
CAM Menu: the CAM menu will appear here when inserted. Click the
tabs for more info