Page 1
OWNERS MANUAL ICED TEA BREWING SYSTEM MODELS: 8742 8748 Includes: Installation Operation Use & Care Servicing Instructions Model 8748 Brewer with optional 8602 Iced Tea Dispenser PRINTED IN UNITED STATES OF AMERICA 76116 Rev. G ECN-13385 M606 1114 cps...
Wells Bloomfield cannot assume liability for damage or loss is signed by the delivery person. incurred in transit. We will, however, at your request, supply FILE CLAIM FOR DAMAGE IMMEDIATELY: you with the necessary documents to support your claim.
3 Gallon 10-15/16" wide 1500 12.5 NEMA 5-15P Iced Tea 15-11/16" deep Brewer 8748 35-1/4" high 5 Gallon 10-15/16" wide 1500 12.5 NEMA 5-15P Iced Tea 15-11/16" deep Brewer APPLICABILITY This manual applies to the following Wells Bloomfield products: 8742 8748...
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all...
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: Unpack the unit. Inspect all components for completeness and To enable the installer to make condition. Ensure that all packing materials have been removed a quality installation and to from the unit. minimize installation time, the Verify that the Spray Head Gasket and Spray Disk are properly following suggestions and tests...
Page 7
Models 8742 and 8748 are equipped with a cord and plug. brewer or result in decreased They require a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire performance.
OPERATION Fig. 3 Brewer Operation Diagram IMPORTANT: A. START-UP Tank must be full of water For initial start-up, or if the brewer has not been used for an before pressing TANK extended period of time: HEATER SWITCH " ". ♦ Be sure spray disk and brew gasket are properly installed in the Heating elements will be brew head.
OPERATION (continued) WATER HEATER Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the mechanical thermostat. The temperature setpoint is adjustable. Heating element is energized by the thermostat. Excessive temperature will trip the hi-limit safety switch.
CAUTION: the brew volume. BURN HAZARD Model 8742: 3 Gallons Model 8748: 5 Gallons To avoid splashing or Fig. 7 Tea Brew Chamber overflowing hot liquids, Gently shake the brew chamber to ALWAYS place an empty level the bed of tea leaves.
CLEANING INSTRUCTIONS PROCEDURE: Clean Tea Brewer CAUTION: BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of tea are FREQUENCY: Daily extremely hot. Hot tea will cause serious skin TOOLS: Mild Detergent, Clean Soft Cloth or Sponge burns.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will self- reset Damaged internal component Examine wiring &...
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD TOP PANEL: Remove top panel to access hot water tank, thermostat, timer, Opening access panels on this brew solenoid and brew circuit tubing. brew may expose uninsulated electrical components. Top panel is held by two screws at the rear and a retaining lip at Disconnect brewer from the front .
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Unplug power cord or turn circuit breaker OFF. Remove top panel. These procedures involve Pull vent tube out of tank lid and insert a thermometer of known exposed electrical circuits. accuracy in hole. Reconnect brewer to electrical power. These procedures are to be Place empty container under brew chamber.
Page 15
A total of 3 gallons (Model 8742) of water; or, A total of 5 gallons (Model 8748) of water. To adjust: Remove top panel. Total delivered volume is dependant upon the total time the solenoid is energized.
Page 16
SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing REPLACE HEATING ELEMENT heating element, also replace Remove tank cover assembly (see page 13). seal gaskets. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Symptom: Automatic brewer will not flow water;...
Page 17
SERVICING INSTRUCTIONS (continued) PROCEDURE: Delime the Water Tank CAUTION: CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. FREQUENCY: As required (Brewer slow to heat) Wear appropriate protective gloves and goggles during this TOOLS: Deliming Solution Protective Gloves, Goggles &...
Page 22
Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association SERVICE TRAINING - QUALITY SERVICE SERVICE TRAINING - QUALITY SERVICE Genuine Parts Protect - YOU - All - Ways CUSTOMER SATISFACTION CUSTOMER SATISFACTION WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P.