DH3 WIRELESS GATEWAY USER GUIDE Contents (Index on Next Page) RF REFRESH TIME TAG(S) ......................59 MODBUS WRITE FUNCTION AND WRITING TO DH3 ..............60 Contents (Index on Next Page) ........................2 PEER-TO-PEER/REPEATER/SHARING DATA ................62 PREFACE/SAFETY ............................4 MAPPING AN IMPORT TO AN OUTPUT ON BASE UNIT .............. 64 COMPLIANCES/CONFORMITÉ...
Page 3
DH3 WIRELESS GATEWAY USER GUIDE Index POLLING MODBUS REGISTERS USING BreeZ® .................... 45 POWER CONSUMPTION ..........................8 ADDING IMPORT POINTS TO MODBUS TABLE ................... 44 PRODUCT & SYSTEM OVERVIEW ......................... 7 AUTHENTICATION (USER ROLES) ....................... 38 QUICK REFERENCE - CONFIGURATION/INSTALLATION SEQUENCE ............
DH3 WIRELESS GATEWAY USER GUIDE PREFACE/SAFETY Thank you for choosing the DH3 Wireless Gateway by OleumTech®. WARNING: EXPLOSION HAZARD – Do not use USB connectors in hazardous area. AVERTISSEMENT: RISQUE D'EXPLOSION - Ne pas utiliser les connecteurs USB en This document describes the hardware components and how to install and operate zone dangereuse.
DH3 WIRELESS GATEWAY USER GUIDE 1. COMPLIANCES/CONFORMITÉ FCC Compliance Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable English protection against harmful interference in a residential installation.
DH3 WIRELESS GATEWAY USER GUIDE CONFORMITÉ Réorienter ou déplacer l'antenne. • Augmenter la distance entre l'équipement et le récepteur. • Consultez le fabricant de l'aide technique. • Françias Cet équipement a été certifié conforme aux limites d'un dispositif informatique de classe B, conformément aux règles de la FCC.
Network. When used as a primary Gateway, it serves as the central collection point Wireless Gateway (900 MHz or 2.4 GHz ISM Band) - Serves as a Primary Data Collection Point in OleumTech™ Wireless Sensor and I/O Network of data, which then can be served to any Modbus Master device. The DH3 can...
DH3 WIRELESS GATEWAY USER GUIDE 4. POWER CONSUMPTION I/O EXPANDABLE To a DH3, local I/O points can easily be added using the OleumTech RS485 I/O LCD Plugged In Tx Power 12 Vdc 24 Vdc Expansion System. Digital I/O, Analog 4-20mA, and 0-10 V I/O Modules are Boot available for deployment.
External Enclosure for DH3 Data Logging • DIN Rail (35mm) • Use only OleumTech Industrial-Grade Micro SD Card • USB 2.0 Flash Drive (NTFS format) for Firmware Upgrade Part # SX1000-SD2 (2GB, -40 C˚ to 85 C˚) • Local Color Touchscreen Display and Cable - WX-1000-LCD (Optional) •...
(access only) username: guest password: guest (Web Server only) 1. Download and install latest BreeZ® Software v5.0 or higher to a PC Download Center: http://support.oleumtech.com 9. Select a DH3 in BreeZ® Project Tree (see sec. (requires login credentials) 10.
DH3 WIRELESS GATEWAY USER GUIDE 9. LED STATES (STATUS INDICATORS) *During DH3 boot-up, LED 1 will be in the last known state at the time of shutdown. **Similarly, LED 2 will be on during boot-up with last known color at the time of shutdown. Page 13...
DH3 WIRELESS GATEWAY USER GUIDE 10. WIRING DIAGRAMS (SERIAL AND POWER) 2. Use BreeZ® Software to configure Serial Ports. Right-click on DH3 in Project Tree and select “Edit” b. Click on RTU Port Tab 1 or 2 to edit settings 1.
DH3 WIRELESS GATEWAY USER GUIDE 11. LOCAL LCD DISPLAY 3. Modbus screen View all points or filter view by device NOT HOT SWAPPABLE Disconnect power from DH3 when connecting or disconnecting LCD! Coupez l'alimentation de DH3 pour connecter ou déconnecter LCD ! 1.
Page 16
DH3 WIRELESS GATEWAY USER GUIDE 5. Events screen – Data Logging 7. Serial port screen View System or Event log View the way serial ports are set up 8. Ethernet port screen View Ethernet port settings 6. Radio screen To view the current IP address from LCD, the Ethernet port must be View RF network settings actively connected to a network or third-party Ethernet device such as Router, Switch, IP Radio, RTU, PLC, or PC...
2. Le boîtier du panneau doit être mis à la terre . 2. The panel enclosure must be grounded to earth. 3. Il est sûr de monter OleumTech Wireless Gateways au boîtier du panneau 3. It is safe to mount OleumTech Wireless Gateways to panel enclosure depuis le châssis et les terminaux / sol de puissance numériques sont...
Page 18
DH3 WIRELESS GATEWAY USER GUIDE Grounding Gateways & I/O Modules: Terre passerelles et modules E / S: (Français) • Négative batterie ne doit jamais être commun avec la terre. • Battery negative should never be common with earth ground. • For fiberglass enclosures, the backplane inside may be connected •...
DH3 WIRELESS GATEWAY USER GUIDE 13. INSTALLATION INSTALLATION (FRANÇAIS) La procédure suivante décrit l'installation correcte d'un DH3. The following procedure describes how to install a DH3 Before you perform this procedure, be sure the DH3 meets applicable Avant d'effectuer cette procédure, se assurer que le DH3 répond aux exigences grounding requirements in the enclosure –...
Page 20
DH3 WIRELESS GATEWAY USER GUIDE 1. DH3 Mounting Another view Hook DH3 onto DIN Rail, then press down to compress the spring-loaded mechanism 2. Insert Optional Micro SD Card for Data Logging Use only industrial-grade Micro SD Card part # SX1000-SD2 (2 GB) b.
Page 21
DH3 WIRELESS GATEWAY USER GUIDE 3. Connect Antenna Firmly hold and connect MMCX end of the antenna cable to DH3 Radio (listen for a “click” sound for confirmation) Connect Lightning Arrestor (optional – highly recommended) Drilling a hole may be required for routing antenna cable – use 5/16” or larger diameter, user must supply own O-ring/sealing Use proper fittings to seal hole for antenna cable Where bulkhead (black phantom) antennas are used, the inner surface,...
Page 22
DH3 WIRELESS GATEWAY USER GUIDE 4. Connect LCD Display (Optional) – NOT HOT SWAPPABLE! Latch spring-loaded side of bracket onto top of DIN rail first, then latch using other side Disconnect power from DH3 when connecting or disconnecting LCD! May need to apply firm pressure to top of LCD Display to latch Coupez l'alimentation de DH3 pour connecter ou déconnecter LCD ! the bottom side of bracket properly Latch only top portion of LCD Display on DIN rail...
Page 23
DH3 WIRELESS GATEWAY USER GUIDE 5. Internal RTC “Coin” Battery Replacement (Part # 62-1001-001) Carefully remove battery connector For time keeping and stamping purposes, the DH3 is equipped with a replaceable internal RTC battery. The battery has a shelf life of +10 years depending temperature and storage conditions.
*Field tested with clear line of sight with antennas raised to 9 to 15 ft above ground at sea handful of End Nodes, please consult with an OleumTech Application Engineer or a level (tested for point-to-point values only). Actual wireless RF range may vary depending on Certified Specialist to properly commission a project.
Page 25
7. RF Enhancements How to Enable RF Security in BreeZ® v5.0 or higher To ensure data reliability and delivery over RF, OleumTech Wireless (1) Open or create a BreeZ® project file (v5.0 or higher) Sensor and I/O Network provides RF collision detection for 900 MHz (2) Right-click on “site”...
BreeZ® Software Version 5.x or Higher Required to Run DH3 Select File Location by clicking Browse button BreeZ® Software Download http://support.oleumtech.com BreeZ® Software Compatibility Matrix: http://goo.gl/KzsY01 1. Open BreeZ® Software from Your PC a. BreeZ® v5.x can open Project Files that are v3.3.0.109 or higher b.
Page 27
DH3 WIRELESS GATEWAY USER GUIDE 4. RF Settings 5. Configure Primary Wireless Gateway / RTU Port 1 Settings Select Frequency that matches the Radio Frequency (RF) of the wireless Create Gateway Name devices Select Gateway Type: DH3 Select Channel to avoid any RF conflict with any nearby sites Select Tx Power - (Note: Selecting higher Tx Power consumes more...
Page 28
DH3 WIRELESS GATEWAY USER GUIDE 6. Ethernet / RTU Port 2 Settings 7. Add Transmitter (WT Series RTD as Example Used) Series – Select WT Series – LCD Select DHCP Client or Static IP Addressing Transmitter: Select RTD If using Static Addressing, enter network information Click button For help setting up Ethernet connectivity, please consult with your IT...
Page 29
DH3 WIRELESS GATEWAY USER GUIDE 8. Configure Transmitter Modify Template to desired settings Exported tags will automatically be added to the Modbus Mapping Table i. Fahrenheit: Temperature Unit ii. Celsius: Temperature Unit iii. Battery Voltage: Indicates Battery level: ≥ 2.9 V is good Timeout: 0 = RF OK ;...
Page 30
DH3 WIRELESS GATEWAY USER GUIDE NOTE: Once a new Battery Pack is installed, it is perfectly normal to get a 9. Select RTD Wire Type reading of 3.2 to 3.3 V. This is due to the fact that the WT Series Transmitters take battery level while it is under load, providing a reliable method of monitoring battery health.
Page 31
DH3 WIRELESS GATEWAY USER GUIDE To review or change device properties, i. Click on the desired device in the Project Tree Verify the added Transmitter in the Device Table ii. Click (Edit) button Click Finish To add another Transmitter or I/O Module, i.
DH3 WIRELESS GATEWAY USER GUIDE 17. MODBUS MAPPING TABLE MANAGEMENT 4. Export Modbus Mapping Table to View Outside of BreeZ® The DH3 can hold up to 1920 Modbus registers. Please use the following instruction to manage Modbus table. 1. Double-click on Gateway in the Project Tree Click on File menu Select “Export to .CSV…”...
Page 34
DH3 WIRELESS GATEWAY USER GUIDE 5. How to Add a Register from a Device Select a tag(s) from “Exportable Tags” box Single-click on an end node in project tree Click on “E” Edit button Use the left arrow to move it over to “Exported Tags” box Click OK when finished Page 34...
Page 35
DH3 WIRELESS GATEWAY USER GUIDE Double-click DH3 in project tree Click on Modbus tab to verify added register Option: use the mouse to click and drag to desired position Click on Imports tab 16-bit register starting point can be changed in BreeZ® (Range: 0-3001) i.
DH3 WIRELESS GATEWAY USER GUIDE 18. EDITING GATEWAY PROPERTIES 3. RTU Port Tabs: 1 and 2 Allows configurations of two(2) serial ports RTU port can be set as a Modbus Master, Modbus Slave, 1. Accessing DH3 properties window LevelMaster ASCII Slave, or ROC-Link Master Click on DH3 in project tree and right-click and select “Edit”...
Page 37
DH3 WIRELESS GATEWAY USER GUIDE 4. Ethernet Port Tab Double-click on Slave row to edit settings Allows using DHCP client or static addressing Allows enabling or disabling of Modbus TCP/IP services 5. USB Port Tab Allows available USB services to be enabled or disabled. Double-click on Master row to change settings Page 37...
DH3 WIRELESS GATEWAY USER GUIDE 19. AUTHENTICATION (USER ROLES) 4. After opening BreeZ® Software and first attempting to update, connect, or create a Debug session, users will be prompted to fill in the credentials and to select connection type For security purposes, authentication is required to access DH3, locally or remotely.
DH3 WIRELESS GATEWAY USER GUIDE 20. UPDATE DH3 FUNCTION IN BreeZ® 1. Connect 9-30 VDC power to DH3 (PROGRAM/CONFIGURE DH3) DH3 can be programmed or “updated” using a Mini USB or Ethernet connection. In order to keep intruders out, accessing DH3 requires user authentication.
Page 40
DH3 WIRELESS GATEWAY USER GUIDE Ethernet – Configure and connect DH3 to a network 5. If the Gateway was used with another Project File, the Site Security Mismatch window will appear i. Click Ignore Key to preserve existing key on the device ii.
DH3 WIRELESS GATEWAY USER GUIDE 21. CONNECT TO DH3 FUNCTION IN BreeZ® 3. Device Tab Displays how the device is set up Displays Firmware version When a DH3 is connected to BreeZ® Software, users can also directly Verify RF Security settings access the settings stored on the device.
DH3 WIRELESS GATEWAY USER GUIDE 6. USB Port Tab 22. DEBUG SESSION Displays Port status and available services over USB. To view DH3’s debug log, user must manually create a debug session. see sec 19 for DH3 authentication 1. Right-click over a DH3 in Project Tree and select Create DH3 Debug Session 7.
DH3 WIRELESS GATEWAY USER GUIDE 23. DH2 TO DH3 CONVERSION IN BreeZ® 5. Click “Yes” when prompted to save project file before continuing to convert Converting DH2 to DH3 cannot be undone 1. DH3 can be used to replace a DH2 DH3 cannot be converted back to DH2 BreeZ®...
DH3 WIRELESS GATEWAY USER GUIDE 24. ADDING IMPORT POINTS TO MODBUS TABLE 4. Right-click over highlighted area and select paste to integer or float table Any points contained in DH3’s Import tab can be exported or added to DH3’s Modbus Mapping table so that those points can be monitored by another Modbus Master device.
DH3 WIRELESS GATEWAY USER GUIDE 25. POLLING MODBUS REGISTERS USING BreeZ® 5. Select Desired Registers BreeZ® Software provides users the ability to poll Modbus registers from a 6. Right-Click over Highlighted Area and Select Poll Modbus Register(s) Wireless Gateway for installation verification. This feature allows users to take a poll once per command.
RAM, exporting the .csv file is recommended prior to re-booting or updating DH3. DH3 Serial Number 0178730001 and higher are equipped with a Micro SD Card slot. Use only OleumTech Part Number SX1000-SD2 Industrial-grade Micro SD Card for data logging. 4. Right-click on the point and select logging DH3 internal clock must be setup properly see sec.
Page 47
DH3 WIRELESS GATEWAY USER GUIDE 5. Status - enable logging using dropdown menu 7. Threshold - enter triggering point Rising (triggered when ≥ equal or greater than threshold value) Falling (triggered when ≤ equal or less than threshold value) 8. Event Control – select deadband or on-delay 6.
Page 48
DH3 WIRELESS GATEWAY USER GUIDE 9. Enter Lower limit or On-Delay time in seconds 10. Confirm logged point 11. Save project file and update DH3 Page 48...
Page 49
DH3 WIRELESS GATEWAY USER GUIDE 12. How to export event log using BreeZ® software Save .CSV file to preferred destination Connect DH3 to PC Click on DH3 in project tree Click connect button Click Device tab and select “Export Events” Export Events button will be enabled if Event logging is enabled Point ID Value...
.csv file is recommended prior to re-booting or updating DH3. DH3 Serial Number 0178730001 and higher are equipped with a Micro SD Card slot. Use only OleumTech Part Number SX1000-SD2 Industrial-grade Micro SD Card for data logging. Use Formula to Determine Max Range: 800,000 / (points * (86400 / interval secs)) 4.
Page 51
DH3 WIRELESS GATEWAY USER GUIDE 5. Edit Trending Parameters 6. Edit Y-Axes Labels and Units Create Name and Title Click on Y-Axes tab b. Set Sampling Interval in Hour:Minutes:Seconds b. A trend can have up to 4 Y-Axes Duration – enter duration in days Use Add button to add Y-Axis (max duration depends on number of points and sampling interval)
Page 52
DH3 WIRELESS GATEWAY USER GUIDE Select Y-Axis 8. How to Modify a Created Trend Click on Trending tab b. Select a desire trend group, right-click and select Modify 9. How to Enable or Disable a Trend Click on Details tab b.
Page 53
DH3 WIRELESS GATEWAY USER GUIDE 12. How to Export Trends in BreeZ® Select location and save .csv file When exporting trends, BreeZ® software will export all trend groups into one .csv file b. Connect to DH3 If trending is enabled, Export Trends button will be enabled. Open .csv file d.
DH3 WIRELESS GATEWAY USER GUIDE 28. WEB SERVER 4. Obtain DH3’s IP Address from BreeZ® Right-click on DH3 in Project Tree Through DH3’s Web Server, a user can securely access valuable information without b. Identify a particular DH3 in from the list and use its IP address having to use the BreeZ®...
Page 55
DH3 WIRELESS GATEWAY USER GUIDE 6. If prompted by “This Connection is Untrusted:” For FireFox: For Chrome: Click “I Understand the Risks” option Click “Advanced” b. Click “Add Exception” Click “Confirm Security Exception” b. Click “Proceed to …” For Internet Explorer: Click “Continue to this website”...
Page 56
Use Severity and Area control to filter viewing option 8. Use Main Menu Screen to Navigate to Desired Page Click on OleumTech logo, or home icon to return to this page b. Logging tab i. Use refresh button to poll latest data 9.
Page 57
DH3 WIRELESS GATEWAY USER GUIDE 11. Trending Page d. Zoom In – Click and drag a section of the range to zoom in Use Trend dropdown menu to select a trend b. MUST Select Time range and press to view trend graph i.
Page 58
DH3 WIRELESS GATEWAY USER GUIDE 12. Radio Page 14. Serial Ports Page 13. Ethernet Port Page Page 58...
DH3 WIRELESS GATEWAY USER GUIDE 29. RF REFRESH TIME TAG(S) Adding a RF Refresh Time tag to any Modbus point ensures the data that is held in the Modbus table is valid. When the RF Refresh tag is used for trending, a normal graph will look like a sawtooth.
2. Click on Modbus tab In order to relay data from a third-party Modbus Master device to a point or output in an OleumTech network, a Modbus Write function must be created in the primary Gateway’s Modbus table. Once the function is 3.
Page 61
DH3 WIRELESS GATEWAY USER GUIDE 5. Point will be added to Modbus table 8. Poll Modbus register to view value status 6. Save project file and MUST update DH3 7. Write a value from a Modbus Master device Values must be written as either 16 or 32-bit holding register Page 61...
3. Select a point or points from Import tab from DH3 (origin) to share with another Gateway OleumTech Wireless Sensor Network is extremely flexible by allowing any tags to be shared across multiple Wireless Gateways in a single networking system. Peering allows for more efficient and powerful networking.
Page 63
DH3 WIRELESS GATEWAY USER GUIDE 6. Check map to integer or float point table or both 9. The point(s) is automatically mapped to its Modbus register holding table on Base Unit or secondary Gateway 10. Using shared point based on interval or on change Double-click primary Gateway b.
DH3 WIRELESS GATEWAY USER GUIDE 32. MAPPING AN IMPORT TO AN OUTPUT ON 3. Double-click on a Base Unit in project tree BASE UNIT With the DH3, any import point can be mapped to an available output in the same network whether it be to a Base Unit, Wireless Multi-I/O Module, or another device with an output.
DH3 WIRELESS GATEWAY USER GUIDE 33. MAPPING AN IMPORT TO AN OUTPUT ON 2. Click on DH3 in project file and use + button to add a Wireless Multi- I/O Module to the system WIRELESS MULTI-I/O MODULE Although the DH3 is not equipped with any onboard analog or digital outputs, however, any import point can be mapped to an available output in the same network whether it be to a Base Unit, Wireless Multi-I/O Module, or another device with outputs.
Page 66
DH3 WIRELESS GATEWAY USER GUIDE 4. Double-click on DH3 in project tree 9. Right-click over desired output target and select paste output source 5. Click on Imports tab 6. Select desired point to be mapped to an output 10. Save project file and update both DH3 and Wireless Multi-I/O Module for changes to take into effect 7.
34. RS485 I/O EXPANSION SYSTEM WITH DH3 1. Must have an available Serial/RTU port on DH3 Users can add local I/O points by deploying the OleumTech RS485 I/O 2. Open a BreeZ® project file containing a DH3 Expansion System to a DH3.
Page 68
DH3 WIRELESS GATEWAY USER GUIDE 6. Click on Gateway in project tree and click + Add Device button and 7. Under IO Bus tab, select desired RTU port or Ethernet port select “Modbus Module” If using RTU port, set Slave ID = I/O Module ID on rotary switch dial + 1 If using Ethernet port, set Slave ID = I/O Module ID on rotary switch dial + 1 i.
Page 69
DH3 WIRELESS GATEWAY USER GUIDE 8. Click Modbus Inputs tab and configure input settings 10. How to map inputs reads to DH3’s Modbus register holding table Double-click on Gateway in the Project Tree Refer to Modbus Mapping table Click on “Imports” tab Right-click over import points and select paste to Integer or float table Select “Modbus”...
Page 70
DH3 WIRELESS GATEWAY USER GUIDE 11. How to write to outputs using third-party Modbus Master device Select “Imports” tab and right-click on the newly created “Write” command and select “Copy” Double-click on Gateway in the Project Tree Select “Modbus” tab Right-click in the Window, and select “New Write Import”...
DH3 WIRELESS GATEWAY USER GUIDE 35. MODBUS MASTER FUNCTION 1. Determine if using RTU or Ethernet port on DH3 2. Open a BreeZ® project file containing a DH3 Either DH3’s RTU port or Ethernet port can be used to set the DH3 as a Modbus Master device.
Page 72
DH3 WIRELESS GATEWAY USER GUIDE 5. Ethernet port method 6. Click on Gateway in project tree and click + Add Device button and select “Modbus Module” Click on Ethernet port tab Double-click on Modbus TCP/IP Master row Check box to enable Master mode of operation Page 72...
Page 73
DH3 WIRELESS GATEWAY USER GUIDE 7. Under IO Bus tab, select RTU or Ethernet port 8. Click Modbus Inputs tab and configure input settings If using RTU port, select Slave ID Set read interval and rest of settings If using Ethernet port, select Slave ID and port address and IP address 9.
Page 74
DH3 WIRELESS GATEWAY USER GUIDE 10. How to map inputs reads to DH3’s Modbus register holding table 11. How to write to outputs using third-party Modbus Master device Double-click on Gateway in the Project Tree Click on “Imports” tab Double-click on Gateway in the Project Tree Right-click over import points and select paste to Integer or float table Select “Modbus”...
Page 75
DH3 WIRELESS GATEWAY USER GUIDE Select “Imports” tab and right-click on the newly created “Write” command and select “Copy” Select “Outputs” tab and right-click on an output point and select “Paste Output Source” Save project file Update DH3 for changes to take into effect Page 75...
DH3 WIRELESS GATEWAY USER GUIDE 36. ROC LINK MASTER 2. Insert ROC Link Module for DH3 DH3 can be configured as a ROC Link Master through the Serial/RTU Port 1. It supports two Opcodes Opcode 17: login request Opcode 10: read configurable opcode data 1.
Page 77
DH3 WIRELESS GATEWAY USER GUIDE 3. Configure ROC Link Module 5. Configure Points Enter ROC information and Security if needed 6. Verify ROC Module Added in Project Tree Once Configuration is 4. Set Read Interval and Click Add Button to Add Points (supports up to Complete 10 points) 7.
(USB Port must be enabled) b. Using a PC with BreeZ v5.0 or higher DO NOT UNPLUG USB FLASH DRIVE UNTIL UPGRADE IS COMPLETE! 1. Download Latest Firmware Package from OleumTech Download Center – support.oleumtech.com 2. Save Firmware Package onto a USB Flash Drive or PC 4.
DH3 WIRELESS GATEWAY USER GUIDE 38. COM PORT SETUP ON PC AND BreeZ® FOR v. Identify COM Port ID NON-DH3 DEVICES For programming devices such as DH2, Base Unit, Wireless Transmitters, or Wireless I/O Modules, the PC’s COM Port must be configured for use. 1.
Page 80
DH3 WIRELESS GATEWAY USER GUIDE Select COM Port ID that matches what you found in Device Manager vi. Use dropdown box to select COM Port DO NOT CHANGE THE BAUD RATE! vii. This baud rate setting is for your PC COM Port viii.
DH3 WIRELESS GATEWAY USER GUIDE 39. TRANSMITTER UPDATE – CABLE METHOD (PROGRAM / CONFIGURE) 3. Update/Upload Transmitter Using BreeZ® Project File Click on Transmitter in the Project Tree Click (Update Device) button 1. Remove Enclosure Cover from Transmitter (Be Sure Battery Pack Is Connected to Puck or PC Board) 2.
DH3 WIRELESS GATEWAY USER GUIDE 40. DH2 or BASE UNIT GATEWAY UPDATE Click Flash button to begin the update Firmware process (PROGRAM / CONFIGURE) a) Connect Power to Gateway (9-30 V) b) Connect Gateway to PC Connect USB to Serial Adapter to PC (USB) Setup COM Port ID on PC and BreeZ®...
DH3 WIRELESS GATEWAY USER GUIDE 41. SAVING PROJECT FILE TO GATEWAY 4. Select Desired Project File from PC or Another Drive Source and Click OK BreeZ® Software version 4.0 and higher allows users to save the Project File onto any Wireless Gateway (also requires Gateway Firmware version 1.3.0.93 or higher).
DH3 WIRELESS GATEWAY USER GUIDE 42. RETRIEVING PROJECT FILE FROM GATEWAY 6. Select a Location to Save the Retrieved File 1. Connect Gateway to PC Using Proper Cables 2. Open BreeZ® Software 3. Close Project Creation Wizard 4. Click “R” (Retrieve Project File) Button a.
DH3 WIRELESS GATEWAY USER GUIDE 43. WIRELESS SITE SECURITY KEY File Saving Behavior in Relations to Site Security Key will change when: i. Saving a new project file in BreeZ® 1. Default: When creating a new project file in BreeZ®, Site Security is ii.
Page 86
DH3 WIRELESS GATEWAY USER GUIDE 3. What To Do When Key is Lost Double-click on “Site” in the project tree and verify key change If a key is lost or switched accidentally to an existing project file, the key can be retrieved from the Gateway Connect Gateway to PC Double-click on “Gateway”...
DH3 WIRELESS GATEWAY USER GUIDE 44. RESETTING DH3 PASSWORDS Select connection type Right-click on a DH3 in Project Tree and select “Reset Passwords” Page 87...
Page 88
DH3 WIRELESS GATEWAY USER GUIDE Click on the link below to go to OleumTech Download Center’s Copy and paste Reset Passcode and enter Download Center password reset page Username, then click “Reset Passwords” http://support.oleumtech.com/dh3-reset-passcode User must have access to support.oleumtech.com Copy and paste DH3 MAC address and Unique Key, then click “Generate Reset Passcode”...
Page 89
DH3 WIRELESS GATEWAY USER GUIDE Enter default username (admin) and password (admin), select Enter new passwords for desired level of access, then click OK connection type, then click OK Repeat this step to change password for other levels Confirm password change Store password in a safe place Page 89...
DH3 WIRELESS GATEWAY USER GUIDE 45. TEMPLATING FROM A MASTER BreeZ FILE In the project tree, right-click on a device to be disabled and select “Disable Device” BreeZ® Software version 5.3 and higher provides improved method for using a project file as a master template for commissioning multiple sites. Provides the ability to disable devices that automatically disables all of their mapped I/O points from the project file.
Page 91
DH3 WIRELESS GATEWAY USER GUIDE b. Outputs tab shown (Mapped output is disabled, row 2) If file is being utilized for a new site, use the “Save As” function to assign a new site security for the Project File Update impacted Gateways To re-enable a device, right-click on a disabled device, and select “Enable Device”...
Micro-USB.) 1. DH3 not communicating with BreeZ® Software (PC, USB to Mini-USB) 2. DH3 not communicating with BreeZ® Software (Ethernet) 3. DH3 not communicating with OleumTech Wireless Devices 4. DH3 cannot communicate via RTU port (Master/Slave) 5. Resetting DH3...
DH3 WIRELESS GATEWAY USER GUIDE 1. DH3 Not Communicating with BreeZ® Software (PC, USB to Mini- USB) 1. Try power cycling DH3, it may take up to 30 seconds Try rebooting the PC For Windows 7 or 10-based OS: try updating the “USB Ethernet/RNDIS Gadget” driver on PC (usb8023.sys) 1.
• If there are other OleumTech equipment in the area on a different project file, ensure the channel # is different to avoid RF interference and/or crosstalk Page 94...
• Verify the wiring from the DH3 to the 3 party device • Download Center Access: http://support.oleumtech.com • Verify the RTU port is set up correctly (Modbus Master or Slave) • Internet connectivity to access Download Center •...
DH3 WIRELESS GATEWAY USER GUIDE 47. TROUBLESHOOTING – TRANSMITTER 1. Radio / Antenna Symptom: Action/Resolution: • Confirm that Antenna has a clear line of sight to all devices. • Reset the device. • Site Security Key may not match Gateway and other devices. Update Site Security and update all devices with the No communication with Wireless Gateway same Project File.
Page 97
DH3 WIRELESS GATEWAY USER GUIDE 2. Hardware Connection Symptom: Action/Resolution: • Verify the Battery Pack is securely connected to the device. • Verify Configuration Cable is securely connected to the device and PC. Device cannot communicate with BreeZ® • Verify the COM port settings in BreeZ® are correct. Verify the Baud Rate is 57600 and the Parity is 8-N-1. •...
Page 98
DH3 WIRELESS GATEWAY USER GUIDE 3. Configuration Symptom: Action/Resolution: • Update all devices with the same Project File. • Confirm Antennas have a clear line of sight to all devices and are within approved distances. • Change the site Channel ID and update all devices. Transmitter is not communicating with Wireless Gateway •...
Channel - one of either 10 hopping sequences (900MHz) or 12 direct sequence channels (2.4GHz) used to isolate radio communications. COM Port - a serial communication physical interface through which information transfers in or out one bit at a time. Configuration Port - the COM Port used to configure an OleumTech device. Page 99...
Page 100
EFM - Electronic Flow Meter. communication between many devices connected to the same network. End Node - OleumTech network device that monitors process conditions. Modbus Master - A device that polls (requests and sends) information from one or more Slave devices in a Modbus network.
Page 101
DH3 WIRELESS GATEWAY USER GUIDE Modbus Module - Used when a port on a receiver is set to Modbus Master mode. Used to read and RAW Units - Digital representation of an analog signal. write values to a Modbus Slave device. Refresh Time - Count that increases every one (1) second.
DH3 WIRELESS GATEWAY USER GUIDE 51. REVISION HISTORY Revision H Updated Regulatory Certifications in sec 2 Revision A Revision J Original release of document Sec 26 and 27 – removed the ability to store event data logging and trending on a USB flash drive throughout the document.
Page 104
Fax: 949.305.9010 www.oleumtech.com OleumTech has made a good faith effort to ensure the accuracy of the information in this document and disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties, except as may be stated in its written agreement with and for its customers.
Need help?
Do you have a question about the WG-0900-DH3 and is the answer not in the manual?
Questions and answers