Quick Links

CHT5 / CHT51
CHT5 / CHT51
Original Operating Instructions
Original Operating Instructions
CHT5-2 / CHT51-2
CHT5-2 / CHT51-2

Advertisement

Table of Contents
loading

Summary of Contents for Captron CHT5

  • Page 1 CHT5 / CHT51 CHT5 / CHT51 Original Operating Instructions Original Operating Instructions CHT5-2 / CHT51-2 CHT5-2 / CHT51-2...
  • Page 2: Dimensional Drawing

    Dimensional drawing CHT5 2/15 CHT5 / CHT51...
  • Page 3 CHT51 CHT5 / CHT51 3/15...
  • Page 4: Technical Specifications

    Technical specifications CHT5 and CHT51 PNP-NO, 4-pin 24 V Operating voltage DC 24 V (16.8 …32 V) Load current Max. 200 mA Output pulse ~ 1 s (depending on the actuation duration) Reverse polarity protection Protection of all lines Short circuit protection...
  • Page 5 CHT5 PNP-NO, 4-pin 110 V Operating voltage DC 110 V (77 …137.5 V) Load current Max. 15 mA Output pulse ~ 1 s (depending on the actuation duration) Reverse polarity protection Protection of all lines Short circuit protection Protected against short circuit and overload Voltage drop Max.
  • Page 6: Connection Plan

    LED2 Load blue PNP-NO, 5-pin brown +VDC white +VDC / LED1 grey +VDC / LED2 LED1 black PNP-NO LED2 Load blue Connection options Connector CHT5-26#…. CHT51-26#…. CHT5-2M#…. CHT51-2M#…. Connector JST 2.54, 4-pin Connector JST 2.0, 5-pin 6/15 CHT5 / CHT51...
  • Page 7: Intended Use

    This manual has been written for technicians/installers and operators and should be kept for future reference. Read these operating instructions carefully and make sure that you have fully understood the contents before installing or working with the CHT5 or CHT51. Safety WARNING Improper work on electrical systems! Electric shock can result in death or life-threatening injuries.
  • Page 8: General Description

    LEDs to indicate operating conditions. The LEDs are actuated differently depending on the pin configuration. A Colored position ring B Pane of glass CHT5, single pane CHT51, double pane C Mounting flange BF-95-2 D SENSORswitch E Colored cover ring AR5-2X_...
  • Page 9 Assembling the mounting flange NOTICE Soiled bond areas prevent proper assembly! Protect the bond area from soiling. Do not touch the bond area. If the bond area has been touched or soiled, use a new mounting flange. CHT5 / CHT51 9/15...
  • Page 10 (A) must be facing the pane of glass. ► Press the sensor element into the mounting flange and check whether the sensor element is flat on the pane of glass. ► Lay the fastening cable between the ridges (B). 10/15 CHT5 / CHT51...
  • Page 11 ► Clean the surface with cleaning cloth A. ► Dry the surface with a lint-free cloth. ► Clean the surface with cleaning cloth B. ► Dry the surface with a lint-free cloth. CHT5 / CHT51 11/15...
  • Page 12: Maintenance Operations

    Clean the switch surface NOTICE Solvents contained in cleaning agents can attack the plastic of the button! Clean the surface of the button with a neutral cleaning agent or a damp microfiber cloth. 12/15 CHT5 / CHT51...
  • Page 13 Disassembling the mounting flange and colored position ring NOTICE If the temperature of the hot air fan is set too high, this may damage the surrounding labels and pane of glass! Do not set the temperature too high. CHT5 / CHT51 13/15...
  • Page 14: Color Variations

    Remove all remaining glue residues from the pane using label remover. Disposal Electrical and electronic components of various types must be recycled according to their type. Options 11.1 Color variations RAL5015 RAL6024 RAL3020 RAL1023 RAL7042 RAL9017 14/15 CHT5 / CHT51...
  • Page 15 11.2 Angle variations colored cover ring 11.3 Raised pictograms and Braille characters Imprint The operating instructions have been authored and published by CAPTRON Electronic GmbH – Johann-G.-Gutenberg Straße 7 – 82140 Olching – Germany Copyright 2018 CHT5 / CHT51 15/15...