Becker a100/25 Assembly And Operating Instructions Manual

Becker a100/25 Assembly And Operating Instructions Manual

Sectional door drives

Advertisement

A100/25
Assembly and Operating Instructions
en
Sectional door drives
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2349 300 021 0a     16/11/2018   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the a100/25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Becker a100/25

  • Page 1 A100/25 Assembly and Operating Instructions Sectional door drives Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2349 300 021 0a     16/11/2018    Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Intended use .................................. 3 Safety instructions ................................ 4 Product overview and dimensions ............................ 6 Installation...................................  7 Emergency manual operation ...............................  7 Voltage switching ................................ 11 Electrical connection to the control unit and connection diagram .................. 11 Checking the running direction ............................
  • Page 3: General

    General These drives are quality products with many features and advantages. • Compact design • Can be installed in any position • Plug-in control cable • Universal power supply 3~230 V/400 V/50 Hz • TÜV type examination – Mark approval certificate in accordance with DIN EN 12453 Please observe these Assembly and Operating Instructions when installing and setting the equipment.
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. General information • The safety instructions set out in EN 12453, EN 12445, EN 60335, VDE 0100 and ASR A1.7 must be ob- served.
  • Page 5 these drives the door must be prevented from falling down through the installation of an anti-drop or spring break safety device. - The signal contacts of the external safety device must comply with PL c. Operating notes • Do not allow children to play with permanently mounted regulating or control devices. •...
  • Page 6: Product Overview And Dimensions

    Product overview and dimensions All dimensions in mm. Drives with a crank handle (HK) Drives with a light chain (LK) 6,35 M 8 x 10 Hole pattern Ø 25,4...
  • Page 7: Installation

    Installation Caution Before installing the drive, the driven part must be checked with regard to its mechanical condition and to ensure smooth opening and closing. During installation of the drive, access to the danger zone must be blocked off. The drive must be properly mounted on a mounting or torque supporting plate (in accord- ance with the output of the drive) with adequate stability.
  • Page 8 (applies to cam-operated limit switching) The door must not be moved beyond the limit positions as otherwise a safety limit switch (S1F/S2F) is activated. If activated, electrical operation of the door system is only possible when the safety limit switch (S1F/S2F) is “released” via emergency manual operation. 2 different systems are available for emergency manual operation: •...
  • Page 9 Ensure that the centric mount on the chain wheel with the round hole and not the hexagon is placed on the coupling shaft on the drive first (3.). Now secure the chain wheel using a washer, spring washer and screw (4.). Tighten the screw (M8 – wrench size 13) firmly whilst locking up the chain wheel (e.g.
  • Page 10 Insertion of the chain ends Take the short chain strand and align it so that the chain links are not twisted (5.). Now insert the last link in the chain (6.) in the chain cross provided (7.) in accordance with its alignment. Pull the chain end which has just been inserted through the chain cross until approx.
  • Page 11: Voltage Switching

    Operation   In order to prevent repeated coupling and decoupling of the emergency manual operation mechanism, the chain must be kept taut during operation. The door can be opened and closed manually by pulling the respective side of the chain vertically. In order to prevent electrical operation of the door system during emergency manual operation, the safety switch S3F is activated when the chain is pulled.
  • Page 12: Checking The Running Direction

    To connect the drive to the control unit, only use original manufacturer-approved 12-core or 18-core cables. The connecting cable is plug-in. In order to ensure strain relief and the degree of protection, the gland must not be undone. The 10-pole jumper plug in the drive must be removed before plugging in the 18-core cable.
  • Page 13: Maintenance

    3. Rotate the black cam S6 "CLOSE" on its shaft until the precision set screw is within easy reach. Now use the precision set screw (slotted) to manually set the cam in such a way that it activates the switch. Move the door slightly up and down again un- til the end switch stops the door.
  • Page 14: Technical Data

    Technical data Type Unit A100 Output torque Output speed Diameter of hollow shaft 25.4 Operating voltage 3~230 / 400 Frequency Nominal current 4.6/2.6 Power factor 0.64 Cycles Insulation material class Thermoswitch °C Degree of protection Limit switch range Revolutions Static holding torque On-site fuse protection 3x10 AT Permissible ambient operating...