TESTING AND ADJUSTMENTS

The TEST mode overrides the photocell (daylight shutoff
feature) and allows the light fixture to be tested day or night
when the DUALBRITE switch is in the TEST position. The
light will stay on for 5 seconds after all motion has stopped.
CHANNEL
OFF
A B
C
Sensor Controls
1. Slide the CHANNEL switch to OFF.
2. Slide the DUALBRITE switch to TEST.
3. Set sensitivity control (SENS) to MIN position.
4. Turn on the circuit breaker or fuse and the light switch.
5. Allow the sensor to completely warm up (90 seconds)
before beginning the setup process.
6. Perform a walk test. Walk through the coverage area
noting where you are when the lights turn on.
7. Stop, wait for the light to turn off (5 seconds), and then
begin walking again. Continue this process until the
detection zone has been established.
6 ft .
(1 .8 m)
30 ft . (9 .1 m)
Maximum Range
209819-01
DUALBRITE
+
SENS
OFF TEST 4H
D2D
Maximum
Coverage Angle
(Top View)
8. Move the sensor head left or right to change the coverage
area. Note: Grasp the sensor only as shown and turn
the entire sensor. Any other method may damage
the sensor. Do not force it past the stops.
9. Adjust the sensitivity (SENS) to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage area
(see Testing and Adjustments or Troubleshooting section).
Rotating Sensor Head to Change Coverage Area
This light has been designed with Link technology which
allows multiple lights to be connected together wirelessly.
Linked lights can be grouped into one of three possible
channels to create linked zones of lighting. See Link Tech-
nology section for more information.
1. Slide the CHANNEL switch to the desired channel
(A, B, or C) on all lights to be linked together.
2. Slide the DUALBRITE switch to the TEST position
on all of the selected lights. Note: The TEST mode
overrides the photocell (daylight shutoff feature) and
allows the light fixture to be tested day or night.
150°
3. Walk in front of each light to ensure all linked lights
are activated from another linked light. Note: The linked
lights may not come on at the same time because of the
delay of the transmission signal.