Program The Module; Programming Guidelines - NetworX NX Series Installation Instructions Manual

Receiver modules
Table of Contents

Advertisement

Table 3. Module Programming Worksheet Table
(cont.)
Location
Segment 1
50 (All
1 - Keyfob user ID
default off)
(off = all keyfobs
report as user 99;
on = keyfob reports
as its learned zone)
2 - Enable jam detect
3 - Enable antenna
tamper (Only
selectable on Inter-
national versions,
reports as box
tamper)
4 - Enable auto
advance to next
zone number
5 - Enable partition 1
audible program-
ming beeps
6-8 Not used
51 (Default
Starting zone number
= 0)
for receiver
0 = 1* (default)
1 = 9
2 = 17
3 = 25
4 = 33
5 = 41
(* When set to 0, the
starting zone number
is determined by DIP
switch 3 setting.)
Enroll the Module
The following steps describe how to enroll and program the
module to be supervised by the NX-8.
1)
With power applied and the system disarmed, enter [ ]
[8] at the keypad. The five function lights should start
flashing.
2)
Enter the "Go To Program Code" (factory default is 9 7
1 3). The service light should flash and the five func-
tion lights should change from flashing to on steady.
3)
Enter [0] [#], where [0] is the NX-8 control panel num-
ber and [#] is the entry key. The Armed LED should
turn on, indicating the control panel is waiting for a
programming location entry.
4)
Enter [9] [1] [5] [#] to enroll the module for supervi-
sion. The keypad sounder should beep three times indi-
cating the NX-8 has accepted the enrolling request.
5)
Exit program mode by entering [EXIT] [EXIT]. The
Service LED on the NX-8 turns on, indicating the con-
trol panel is enrolling the module. After about 12 sec-
onds, the service LED should turn off.
Segment 2

Program the Module

The following steps describe how to get the module into
program mode, load factory defaults if installing a new sys-
tem, and program transmitters into memory.

Programming Guidelines

When a transmitter is learned into memory, the module
claims a block of eight zones around that number (1-8,
9-16, 17-24, etc.). For example, learning a transmitter
into zone 13 automatically claims the zone block of 9
through 16. Only wireless transmitters can now be
assigned to these zones.
Do not learn wireless transmitters into a zone block
claimed by a hardwire expander or the panel.
If two modules are installed, they cannot share the
same zone block. For example, wireless transmitters
learned into zones 11 and 12 must reside in one mod-
ule.
Fill in Table 4 to help keep track of zone block module
assignments. Be sure to circle the module type; RM =
receiver module, HE = hardwire expander, P = panel.
Table 4. Zone Block Module Assignments
Zone Block
1 - 8
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
To program the module:
1)
Enter [ ] [8] at the keypad. The five function lights
should start flashing.
2)
Enter the "Go To Program Code" (factory default is 9 7
1 3). The service light should flash and the five func-
tion lights should change from flashing to on steady.
3)
Enter [XX] [#], where [XX] is the DIP switch setting
module number and [#] is the entry key. The Armed
LED should turn on, indicating the control panel is
waiting for a programming location entry.
4)
For new installations, enter [9] [1] [0] [#] to load fac-
tory defaults and clear any unwanted information in
memory before any further programming.
NetworX NX Series Receiver Modules
Assigned To Module
RM HE P #______
RM HE P #______
RM HE P #______
RM HE P #______
RM HE P #______
RM HE P #______
Page 9