Product Summary
The NX-Series Receiver Modules (8-zone NX-408, 16-zone
NX-416, and 48-zone NX-448) add wireless capabilities to
®
the Caddx
NetworX NX-8 control panel. Adding a receiver
module makes NX-8 control panels compatible with NX
wireless transmitters and keychain touchpads (keyfobs).
The receiver modules mount inside the NX-8 cabinet and
require just three wire connections for power and data com-
munications to the NX-8 motherboard.
Installation Guidelines
Use the following guidelines when installing receiver mod-
ules:
"
Leave at least 10
above the control panel for the mod-
ule's antennas.
Avoid areas that are likely to expose the module to
moisture.
Avoid areas with excessive metal or electrical wiring,
including furnace and utility rooms.
Installing the Receiver Module
The following steps describe mounting the circuit board
edge guide standoff, securing the module to the cabinet, and
inserting the antennas.
CAUTION:
You must be free of static electricity before
handling circuit boards. Touch a bare metal
surface or wear a grounding strap to dis-
charge yourself.
1)
After mounting the NX-8 cabinet, install the ground
plane screws, washers, and nuts (included) in the holes
on top of the cabinet (see Figure 1).
TOP OF
ENCLOSURE
Figure 1. Installing the Ground Plane Screws, Washers,
and Nuts
2)
Install the circuit board edge guide standoff in the
lower mounting hole, in either of the two spaces
located just to the left of the NX-8 motherboard (see
Figure 2). Do not tighten the standoff at this time.
Figure 2. Installing the Circuit Board Edge Guide
Standoff
NetworX NX Series Receiver Modules
9740G05A.DS4
9740G08A.DS4
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for NetworX NX Series

  • Page 1 9740G05A.DS4 NX-416, and 48-zone NX-448) add wireless capabilities to ® the Caddx NetworX NX-8 control panel. Adding a receiver Figure 1. Installing the Ground Plane Screws, Washers, module makes NX-8 control panels compatible with NX and Nuts wireless transmitters and keychain touchpads (keyfobs).
  • Page 2 NetworX NX Series Receiver Modules Install the module into the cabinet by turning the stand- Wiring, Module Number DIP Switch off sideways, then slide the module up onto the ground Settings, and Power Up plane screw posts (see Figure 3).
  • Page 3 NetworX NX Series Receiver Modules Apply power to the NX-8. The middle (red) LED on Special Settings for Door/Window the module should start blinking. Table 2 describes the Transmitters and Wireless Smoke Detectors module’s status based on LED conditions. Use the following guidelines when setting features 3 and 4 Table 2.
  • Page 4 NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table (cont.) Table 3. Module Programming Worksheet Table Location Segment 1 Segment 2 Location Segment 1 Segment 2 5 (Zone 5) 1 - Enable sensor Partition 1 keyfob Assigned to...
  • Page 5 NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table Table 3. Module Programming Worksheet Table (cont.) (cont.) Location Segment 1 Segment 2 Location Segment 1 Segment 2 10 (Zone 10) 1 - Enable sensor Partition 1 keyfob 15 (Zone 15)
  • Page 6 NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table Table 3. Module Programming Worksheet Table (cont.) (cont.) Location Segment 1 Segment 2 Location Segment 1 Segment 2 20 (Zone 20) 1 - Enable sensor Partition 1 keyfob 25 (Zone 25)
  • Page 7 NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table Table 3. Module Programming Worksheet Table (cont.) (cont.) Location Segment 1 Segment 2 Location Segment 1 Segment 2 30 (Zone 30) 1 - Enable sensor Partition 1 keyfob 35 (Zone 35)
  • Page 8 NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table Table 3. Module Programming Worksheet Table (cont.) (cont.) Location Segment 1 Segment 2 Location Segment 1 Segment 2 40 (Zone 40) 1 - Enable sensor Partition 1 keyfob 45 (Zone 45)
  • Page 9: Program The Module

    NetworX NX Series Receiver Modules Table 3. Module Programming Worksheet Table trol panel is enrolling the module. After about 12 sec- onds, the service LED should turn off. (cont.) Location Segment 1 Segment 2 Program the Module 50 (All 1 - Keyfob user ID...
  • Page 10 NetworX NX Series Receiver Modules Enter [4] [9] [#] to enter the sensor learning location. Table 5. Tripping Transmitters for Learning The Ready LED should turn on and the Armed LED should turn off. Transmitter Action Enter [XX] [ ], where [XX] is a zone number (1 through 48) and [ ] is the entry key.
  • Page 11: Deleting Transmitters

    NetworX NX Series Receiver Modules Press [ ] to save any changes. The panel is now wait- Repeat steps 4 - 8 to continue programming transmitter ing for the next location entry. partition settings. 10) Enter [EXIT] [EXIT] when finished.
  • Page 12: Troubleshooting

    U.L. Listings Test each location until the transmitter consistently tests good, then mount the transmitter. The NetworX NX Series Receiver Modules (60-732) are U.L. Listed for UL1023 Household Burglary, UL985 Household Fire, and are listed for use with the following U.L.

This manual is also suitable for:

Nx-408Nx-416Nx-448

Table of Contents