Gentex GEC24 Series Manual page 2

Visible and/or audible signaling appliances

Advertisement

Available languages

Available languages

Strobe light can not be seen when objects such as doors, furniture or walls block strobe light.
NOTICE:
w THE VISUAL SIGNAL MUST BE IN THE DIRECT VIEWING AREA OF THE OCCUPANT IN ORDER TO BE SEEN.
w VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING IMPAIRED. VISUAL SIGNALS MAY NOT BE THE PREFERRED METHOD
FOR NOTIFYING ALL HEARING IMPAIRED INDIVIDUALS.
w THE STROBE LIGHT MUST BE SEEN BY THE SLEEPING PERSON. IF THE PERSON HAS HEAD TURNED OR OTHERWISE UNABLE TO BE ALERTED BY VISUAL, THE STROBE
WILL NOT BE EFFECTIVE.
24VDC CLEAR Lens Indoor Strobe Current Ratings
GEC24 and
GEC3-24 and
GES24 Series
GES3-24 Series
Available Candela
Available Candela
w
w
w
w
w
w
w
WGEC24, WGES24, WGECA24, WGESA24, WGECB24, WGESB24, WGECG24, WGESG24, WGECR24, WGESR24 PRODUCT INFORMATION
Models
WGECA24, WGESA24
WGECB24, WGESB24
WGECG24, WGESG24
WGECR24, WGESR24
GECA24, GESA24, GECB24, GESB24, GECG24, GESG24, GECR24, GESR24 PRODUCT INFORMATION
Models
GECA24, GESA24
GECB24, GESB24
GECG24, GESG24
GECR24, GESR24
Horn Mode
Temp 3 2400Hz
Temp 3 Mechanical
Temp 3 Chime
Continuous 2400Hz
Continuous Mechanical
Continuous Chime
Whoop
NOTICE:
w THE THREE PULSE TEMPORAL PATTERN IS TO BE USED FOR EVACUATION USE ONLY.
w THE SOUND OUTPUT FOR THE TEMPORAL 3 TONE IS RATED LOWER SINCE THE TIME THE HORN IS OFF IS AVERAGED INTO THE SOUND OUT PUT RATING. WHILE THE HORN IS PRODUCING A TONE
IN THE TEMPORAL 3 MODE ITS SOUND PRESSURE IS THE SAME AS THE CONTINUOUS MODE. UNITS HAVE BEEN TESTED TO 0°C, 49°C AND 93% HUMIDITY.
* Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 sound level required for public mode fire protection service.
These settings are acceptable only for private mode fire alarm signaling use. Use the high dBA setting for public mode applications (the chime tone is always private mode).
Regulated 24VDC
Strobe
Max. Operating
Candela
Current(mA)
15
42
15/75
67
30
58
60
97
75
116
110
161
177
213
24VDC BLUE, GREEN & RED Lens Outdoor
Use with WGECB24, WGESB24, WGECG24,
WGESG24, WGECR24, WGESR24 Products
Candela
75
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY
Color Lens
TESTED TO THE STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM
Amber
OPERATION.
Blue
1 When using products manufactured after 7-1-10, these values are to be used when calculating current draws.
Green
Red
AMBER Lens Indoor Strobe Current Ratings
Use with GECA24 and GESA24 Products
Candela
15
30
60
75
Color Lens
110
Amber
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE
STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.
Blue
1
When using products manufactured after 7-1-10, these values are to be used when calculating current draws.
Green
Red
HORN DECIBEL AND CURRENT RATINGS PRODUCT INFORMATION
Horn Decibel Levels:
Reverberant Room
Minimum SPL
Minimum SPL
at 10Ft. Per
at 10Ft. Per
ANSI/UL 464
ANSI/UL 464
(HIGH)
(LOW)
78 dBA
71* dBA
76 dBA
70* dBA
70* dBA
66* dBA
81 dBA
74* dBA
80 dBA
72* dBA
70* dBA
66* dBA
82 dBA
69* dBA
Regulated 24VFWR
24VDC
Max. Operating
Nominal Operating
Current (mA)
Current (mA)
1
77
30
113
N/A
102
42
161
66
225
80
256
103
341
N/A
Strobe Current Ratings
Regulated 24VDC
Regulated 24VFWR
Max. Operating
Max. Operating
Current (mA)
Current (mA)
164
278
Regulated 24VDC
Regulated 24VFWR
Max. Operating
Max. Operating
Current (mA)
Current (mA)
47
82
64
112
113
178
145
213
178
259
Horn Current Ratings Over
Input Voltage Range of 16-33V
Regulated 24VDC
Regulated 24VFWR
Max. Operating
Max. Operating
Current (mA)
Current (mA)
HIGH Setting
HIGH Setting
28
48
25
44
15
30
28
48
25
44
15
30
56
62
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR
VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS
ONLY TESTED TO THE STATED VOLTAGE RANGE(S); DO
NOT APPLY 80% AND 110% OF THIS RANGE FOR
SYSTEM OPERATION.
1 When using products manufactured after 7-1-10, these
values are to be used when calculating current draws.
N/A: 24VDC nominal operating current data not available
24VDC CLEAR & AMBER Lens Outdoor
Strobe Current Ratings
Use with WGEC24, WGES24,
WGECA24, WGESA24 Products
Regulated 24VDC
Candela
Max. Operating
Current (mA)
1
75
170
BLUE, GREEN & RED Lens Indoor
Strobe Current Ratings
Use with GECB24, GESB24, GECG24,
GESG24, GECR24, GESR24 Products
Regulated 24VDC
Candela
Max. Operating
Current (mA)
1
15
105
30
130
60
203
75
243
110
310
24VDC Nominal Horn
Current Ratings
24VDC Operating
24VFWR Operating
Current (mA)
Current (mA)
HIGH Setting
HIGH Setting
10.7
26.8
9.7
24.5
8.6
20.6
20.4
43.7
17.0
39.3
9.6
23.0
45.4
60.2
Regulated 24VFWR
Max. Operating
Current (mA)
1
263
Regulated 24VFWR
Max. Operating
Current (mA)
1
164
196
325
355
491
550-0011
Page 2