Daikin FBA35A2VEB Operation Manual

Daikin FBA35A2VEB Operation Manual

Split system air conditioners
Hide thumbs Also See for FBA35A2VEB:

Advertisement

Operation manual
Split system air conditioners
FBA35A2VEB
FBA50A2VEB
FBA60A2VEB
FBA71A2VEB
FBA100A2VEB
FBA125A2VEB
FBA140A2VEB
FBA35A2VEB9
FBA50A2VEB9
Operation manual
FBA60A2VEB9
English
Split system air conditioners
FBA71A2VEB9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBA35A2VEB and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FBA35A2VEB

  • Page 1 Operation manual Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 Operation manual FBA60A2VEB9 English Split system air conditioners FBA71A2VEB9...
  • Page 2: Table Of Contents

    1 About this document and-manuals/product-information/ 2 About the system Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. Components ................The original documentation is written in English. All other languages 3 Operation are translations.
  • Page 3: Operation

    3 Operation Outdoor unit Outdoor units Cooling Heating User interface RZQG71~140 –15~50°C DB –19~21°C DB Air inlet Air outlet –20~15.5°C WB Refrigerant piping and electric wiring Drain pipe 18~37°C DB 10~27°C DB Earth wire to ground outdoor unit to prevent electric 12~28°C WB shocks. RZQSG71~140 –15~46°C DB –14~21°C DB CAUTION –15~15.5°C WB...
  • Page 4: Operation Procedure

    4 Energy saving and optimum operation ▪ Turn off the main power supply switch to the unit when the unit is Operation procedure NOT used for longer periods of time. If the main power supply switch is on, the unit consumes electricity. Before restarting the ▪...
  • Page 5: To Clean The Drain Pan

    5 Maintenance and service NOTICE Maintenance MUST be done by an authorized installer or service agent. We recommend performing maintenance at least once a year. However, applicable legislation might require shorter maintenance intervals. CAUTION Before accessing terminal devices, make sure to interrupt Drain plug Phillips screwdriver all power supply.
  • Page 6: Maintenance Before A Long Stop Period

    6 Troubleshooting ▪ Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation. As soon as the power is turned on, the user interface display appears. Troubleshooting If one of the following malfunctions occur, take the measures shown below and contact your dealer.
  • Page 7: Symptoms That Are Not System Malfunctions

    6 Troubleshooting devices actuates to prevent the air conditioner from being Malfunction Measure overloaded. The air conditioner will turn on again automatically The system operates ▪ Check if air inlet or outlet of outdoor or after 3 minutes. but cooling or heating indoor unit is not blocked by obstacles.
  • Page 8: Disposal

    7 Disposal Disposal NOTICE Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. Operation manual FBA35~140A2VEB+FBA35~71A2VEB9 Split system air conditioners...
  • Page 12 4P456964-1C 2018.08...