For The Installer - Scotsman FME504 Installation Manual

Scotsman ice service manual
Hide thumbs Also See for FME504:
Table of Contents

Advertisement

NME454, 654 & FME504, 804

FOR THE INSTALLER

These machines fit the following Scotsman
products, check sales literature for other possible
combinations:
·
SB480 and extensions (with bin top KBT18)
·
B530 using bin top KBT14 or KBT20
·
B842 using bin top KBT28
·
B948 using bin top KBT24
NME654 Dispenser Applications
The NME654 can be placed on and used with
certain ice and ice-beverage dispensers. Kits are
required for proper operation, see the following list:
·
ID150, use adapter KBT42 and KNUGDIV
·
ID200 or ID250, use adapter KBT46 and
KDIL-N-ID2
·
Cornelius ED/DF200 beverage dispensers, use
KBT46 and KDIL-N-200
·
Cornelius ED/DF250 beverage dispensers, use
KBT46 and KDIL-N-250
·
Lancer nugget ice & beverage dispenser, use
KDIL-N-L and Lancer kit #82-3491.
SPECIFICATIONS: ICE MACHINE
Model
Model
Number
Series
FME504AS-1
A
FME504WS-1
A
FME804AS-1
A or B
FME804WS-1
A
FME804WS-1
B
FME804AS-6
A or B
FME804WS-6
A
FME804WS-6
B
FME804AS-32 B
FME804WS-32 B
NME454AS-1
A
NME454WS-1 A
NME654AS-1
A or B
NME654WS-1 A
NME654WS-1 B
NME654AS-6
A or B
NME654WS-6 A
NME654WS-6 B
Note: Minimum Circuit Ampacity is used to determine wire size and type per national electric code.
Dimensions
Basic
Electrical
27" x 21" x 24" 115/60/1
same
same
same
same
same
same
same
same
same
230/50/1
same
same
same
same
same
208-230/60/1 Flake
same
same
same
115/60/1
same
115/60/1
same
same
same
same
same
same
same
230/50/1
same
same
same
same
Installation Limitations:
This ice system is designed to be installed indoors,
in a controlled environment:
Air Temperature
Water Temperature
Water Pressure
Voltage (for 115v model)
(Compared to the nameplate)
Operating the machine outside of the limitations is
misuse and can void the warranty.
Ice
Condenser
Type
Type
Flake
Air
Flake
Water
Flake
Air
same
Water
same
Water
same
Air
same
Water
same
Water
Air
Flake
Water
Nugget Air
same
Water
same
Air
same
Water
same
Water
same
Air
same
Water
same
Water
April 2008
Page 2
Min.
Max.
0
0
50
F
100
0
0
40
F
100
20 PSI 80 PSI
104
126
Minimum
Max.
Refrigerant
Circuit
Fuse
Charge:
Ampacity
Size
R-404A
15.75
20
22 ounces
14.35
20
18 ounces
19.5
30
24 ounces
18.3
30
20 ounces
18.3
30
19 ounces
10.1
15
24 ounces
9.5
15
20 ounces
9.5
15
19 ounces
10.2
15
20 ounces
10.2
15
19 ounces
15.75
20
22 ounces
14.35
20
18 ounces
19.5
30
24 ounces
18.3
30
20 ounces
18.3
30
19 ounces
10.1
15
24 ounces
9.5
15
20 ounces
9.5
15
20 ounces
F
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fme804Nme454Nme654

Table of Contents