DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
WMK-35 Wall Kit Installation
2 x 4
24-1/2
6
5-1/8
4" Dia.
Exhaust
Both
3-1/8
Sides
33-1/4
32
DSKS433
79-1/4
DSKS333
78
2 x 4
WSLP1500
WSLS1500
74-1/8
Standpipe
33" Minimum
If Less Than 33"
38
Use Syphon
Break Kit
WH49X228
23-7/8
28
General Information:
The back of the dryer is not accessible for service or maintenance after dryer mount-
ing installation is complete. It is recommended that the dryer be checked and electri-
cal installation completed prior to mounting. For service or maintenance requiring
rear access, the dryer must be removed from the wall.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE INSTALLING OR
SERVICING DRYER.
The electrical outlet must be located above the dryer, or beside the dryer if adequate
dryer-to-wall clearance is available. The outlet must be within three feet on a 240 volt
dryer or a 120 volt dryer from the service cord entry on the rear of the dryer.
For answers to your Monogram, GE Café
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
prtbl_stnry_bifl_wshr_inst.eps
120V 20A or
208-240V 30A
3-3/4
20" Max.
3
Opening
5-1/8
Rear
8
Exhaust
3
Service
Cord
23-7/8
Entry at
Back of
6
Appliances
1-1/2
120V
46
15 or 20A
23-1/4
Series, GE Profile
®
Service, 800.626.2000.
Dryer Mounting Position
These instructions explain two mounting positions for your 24 inch dryer.
Installation Procedure:
1. Obtain two pieces of 2x4 long enough to span at least two wall studs and the width of the
dryer.
2. Locate wall stud center lines. Mark wall stud center lines on two pieces of 2x4 in
relationship to position dryer is to be mounted.
3. Referring to dimensional drawing, draw a horizontal reference line (72") from the floor to
locate upper 2x4 support.
4. Position, level and secure upper 2x4 with four 1/4 x 3 inch wood screws. The bottom of
R.H
the 2x4 should be positioned on reference line.
EXH
5. Referring to dimensional drawing, draw a horizontal reference line 32" down from the
bottom of the upper 2x4 support.
6. Position, level and secure lower 2x4 with two 1/4 x 3 inch wood screws. The center line
of the 2x4 should be positioned on reference line.
7. Referring to figure 1, mount the metal wall bracket 1/8 inch from the bottom of the upper
2x4 support with five 1-1/2 inch wood screws.
8. Referring to figure 2, remove one screw from each lower rear corner of dryer and, using
same screws, secure lower brackets (supplied) as shown.
9. Dryer is supplied with exhaust at the top, locate and install outside exhaust duct referring
74-1/8
to the dimensional drawing. For other optional exhaust directions as shown in dimensional
drawing (rear and sides) refer to dryer installation instruction sheet.
10. Position the dryer on the wall mounting bracket and check that the dryer is plumbed.
11. If the dryer needs plumbing, use some of the twelve washers supplied with the kit as
spacers behind lower brackets of figure 2 and secure the dryer to the lower 2x4 support
using the remaining 1-1/2 inch wood screws.
WALL BRACKET
2 x 4
1
/
" MAX
8
figure 1
Figure 1
REAR VIEW
figure 2
Figure 2
Series or
wall_bracket_lineart.eps
This kit consists of the following:
1 Wall mounting bracket
2 Bottom Brackets
6-1/4 x 3 inch wood screws
7-1/4 x 1-1/2 inch wood screws
12 washers
Dryer Requirements
Carefully read and follow individual dryer installa-
tion instructions for exhausting requirements.
FRONT VIEW
CAUTION
The 120 volt receptacle on the back
of the 240 volt dryer must not be used
with this wall mount kit.
Specification Revised 2/18