PC Software Download File www.uprtek.com HATO ONE Original / Authorized Agent Stamp * To ensure your warranty validation, please place your agent's stamp in the box and fill in the purchase date. If the agent stamp and purchase date cannot be supplied, the warranty period will based on the manufacturing date of the product.
......38 To get more information related to operation, firmware upgrade 3.16 Connecting with Mobile APP and warranty terms; online application for correction and Repair 3.17 Connecting with uSpectrum ......39 service, please contact one@hato.lighting - 1 - - 2 -...
Page 4
1.1 Packing Contents Appearance Introduction Please check HATO ONE spectro- gallilux meter packing Strap Hole before use, contact your agent if there are missing items. 3.5” Touch Screen SD Card Slot HATO ONE Protection Bag Battery spectro- gallilux meter Reset Key...
Please consult the customer service department for the calibration service: one@hato.lighting 1.4 Product Notes and Precautions HATO ONE spectro- gallilux meter is a high-precision instrument. Please unpack with care. Any vibration or collision may cause instrument damage. If the product doesn’t work normally or needs repair, please don’t attempt any repairs.
Step3. Install the battery after removing battery cover. 3. Power On Status: Users can check HATO ONE screen, it will appear a lightning symbol to indicate charging, and lightning symbol will disappear after being fully charged.
Page 7
Strap installation: HATO ONE. Step1. Unscrew the strap. Step2. Tie the strap to the strap hole of HATO ONE. Step3. Tie the strap to the sensor cover. “Do you want to After the sensor cover is put on, do dark calibration?”...
Page 8
2.1 使用前準備 Preparing Before Use 2.1 使用前準備 2.1 使用前準備 Basic Measurement Set date and time Measure After the dark calibration is completed, please set date and time before Select “Basic” to enter measurement page. measurement. Point the sensor head at the target Go to the next page.
Basic Measurement System Reset Save measurement data Users can press the reset key to turn off the system if system crashes. Reset Key Press Save key on the lower right of the screen, and select “Yes” key. EXCEL file name: ESPDYYYY_MMDD_HHMMSS Fixed (Year) (Month) (Date) (Time) .xls...
Main Page Main Page The interface of the product is touch screen operation. By touching the The interface of the product is touch screen operation. By touching the screen with your figure, you may select the target menu or option. screen with your figure, you may select the target menu or option.
Long time exposure Previous Back to Next Measurement page page measurement page page Capture function Frequency domain (start) One time Operation sound Frequency domain (end) 300Hz Sampling time Setting: Flicker resolution Setting: Flicker resolution Sampling time Time domain (start) Compare mode 0.000s...
ONE is processing continuous measurement. Keyboard Instruction: Key in the number or English letter. Select it to show the Basic mode HATO ONE will process Basic mode input value on the (start measurement) measurement with (after measurement) upper side. press capture key interval of 3 seconds.
Customizing BASIC Mode List 3.7 Instruction of Spectrum Mode The 4 items on the Basic list can be customized with different units of measure (e.g. Gallilux fc, R9, LUX). Interface introduction: Means button Previous Back to Next page BASIC mode page Step1.
FREQUENCY Mode Introduction 3.10 ANALYSE Mode Introduction The analyse button allows you to measure and analyse data of your whole barn trough multiple measurements. Touch the graph to switch the table between Frequency. Press ID to select the number of measurements. Press ID to change to another measuring point.
3.11 CRI Mode Introduction 3.12 Switch Between CIE1931 & CIE1976 After entering the CRI Mode, user may see the Touch the graph to switch the table between CIE1931 measured data such as CRI R1~R15 and Ra. and CIE1976. Interface introduction: Means button 1.
與手機APP連線 3.13 Compare Mode Introduction 3.14 BROWSER Mode Introduction Users can use the real-time measurement or select The Browser (on Home Screen) allows you to review historical the historical measurement data to show the measured data that was previously saved to the SD card. light source data with parallel display.
Insert WiFi Wing card to the system. At IOS or Android platform, download Inside the package has a USB cable, connect the mini USB to HATO ONE HATO ONE APP and install it on your mobile. Then you can connect and plug the USB to your PC then you can read the data saved in SD card.
3.17 Connecting with uSpectrum Install uSpectrum PC software Please visit UPRtek official site, http://www.uprtek.com, Download and install uSpectrum software on the PC. Then you can connect it with the system for USB control of measurement. uSpectrum Install file Set USB PC connection mode Select “PC connection”...
Page 23
Measurement Range 5 to 100,000 lx Sampling Rate 100k sample/sec Frequency Range 5 to 50k Hz HATO ONE spectro- gallilux meter Frequency Resolution 2, 4, 8, 16, 32 Hz *1:Input source must be a stable light source. Flicker Accuracy ± 5% *2 :Temperature 23±2℃...
Page 24
Product Appearance and Dimension Product Appearance and Dimension Back Support Installation Diagram Unit: mm Unit: mm - 45 - - 46 -...
Page 26
2. Repair service: HATO ONE series product for repair. It is recommended taking out the storage device, packing and transporting the ■ If it exceeds the period for changing new product (seven...
Page 27
Product Warranty Terms Applicable Subjects for Warranty Terms Service after Warranty Period If any damage or fault occurs to HATO ONE series product UPRTEK’s warranty service terms are only applicable to the after two years of warranty period, the consumer may still consumers who purchase the company products through return the product to UPRTEK for repair.
Index corresponding unit for average value of R1~ R8. lux in English and The value 100 indicates American units is the foot-candle. One the best quality of light foot-candle is source, while the value 0 approximately 10.764 indicates the worst lux.
Page 29
Measurement Indexes Measurement Indexes Unit Description Abbreviation Full Name closer to that of the blackbody radiation. The The dominant wavelength positive value indicates it is λd Dominant is used to express the color above the blackbody wavelength of the measured light. It (LambdaD) radiation, while the could be hybrided by the...
Page 30
Measurement Indexes Measurement Indexes Flicker percent=(Maximum It is based on the unit of Footcandle Fpercent Flicker value-minimum value)/ lm/ft . ( Maximum value + minimum (Flicker Pct) percent value). Higher value represents obvious flicker. The sensitivity of human eyes Scotopic varies with the light of It is the flicker rate of the Freq...
To get more information related to operation, firmware upgrade card is required to be 1G or higher. HATO ONE? and warranty terms; online application for correction and Repair service, please contact one@hato.lighting Other questions? Visit the FAQ page at our website: www.hato.one - 59 - - 60 -...