Reliable REL-TP SERIES Operator's Manual

Hydraulic trash pumps

Advertisement

OPERATORS' GUIDE
REL-TP SERIES
HYDRAULIC TRASH PUMPS
REL-TP SERIES
The
are a light weight, efficient way to
move large quantities of liquids FAST.
REL-TP3
Trash Pumps
REL-SP SERIES Manual
Sizes, weights and specifi cations
listed in this manual are subject to
change without notice.
P l e a s e c o n s u l t f a c t o r y f o r
information and updates.
1
-1
REL-TP4
NOTICE

Advertisement

Table of Contents
loading

Summary of Contents for Reliable REL-TP SERIES

  • Page 1 OPERATORS’ GUIDE REL-TP SERIES HYDRAULIC TRASH PUMPS REL-TP SERIES Trash Pumps are a light weight, efficient way to move large quantities of liquids FAST. REL-TP4 REL-TP3 NOTICE Sizes, weights and specifi cations listed in this manual are subject to change without notice.
  • Page 2: Distributor Information

    A digital copy of this manual is available on line at www.Reliable-Equip.com THIS SYMBOL INDICATES ITEMS OF EXTREME IMPORTANCE. Obey all safety messages that follow this symbol to avoid possible injury or death.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DISTRIBUTOR INFORMATION ..............2 TABLE OF CONTENTS ................3 REGISTRATION ...................3 REL-TP3 TOOL SPECIFICATIONS ............4 REL-TP4 TOOL SPECIFICATIONS ............5 PUMP PERFORMANCE ................6 SAFETY INFORMATION AND WARNINGS ...........7-10 HYDRAULIC SYSTEM REQUIREMENTS ..........11 HYDRAULIC FLUIDS ................11 OPERATING INSTRUCTIONS ..............12 DAILY MAINTENANCE &...
  • Page 4: Rel-Tp3

    Length ....14 in. (35.5 cm) 301 Ivyland Road • Wa r m i n s t e r, PA 18974 Width ..... 16 in. (41 cm) Phone: 800-966-3530 • Fax: 215-357-9193 Weight ....30 lbs (13.6 kg) Visit us on the web at www.Reliable-Equip.com...
  • Page 5: Rel-Tp4

    Length ....19 in. (48.3 cm) 301 Ivyland Road • Wa r m i n s t e r, PA 18974 Width ..... 15 in. (38.1 cm) Phone: 800-966-3530 • Fax: 215-357-9193 Weight ....59 lbs (26.8 kg) Visit us on the web at www.Reliable-Equip.com...
  • Page 6: Pump Performance

    Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal. REL-TP4 4” TRASH PUMP Consult your supervisor, safety personnel, or RELIABLE EQUIPMENT with any questions regarding the safe operation of this tool.
  • Page 7: Safety Information And Warnings

    BEFORE USING THIS TOOL, READ THE WARNINGS and the recommended practices described in this manual. Failure by the operator to read and fully understand these warnings will leave this person unqualified to use and operate this tool. Property damage, severe personal injury, WARNING and/or death could result by not following these warnings.
  • Page 8 SAFE OPERATION & CARE USE THIS TOOL FOR ITS INTENDED PURPOSE ONLY Any other use can result in injury or property damage. INSPECT TOOL BEFORE USE. Replace any worn, damaged WARNING or missing parts. A damaged or improperly assembled tool may malfunction, injuring operator and/or nearby personnel.
  • Page 9 Never disconnect tool, hoses, or fi ttings while the hydraulic power source is running or if the hydraulic fl uid is hot. IF YOU HAVE ANY QUESTIONS REGARDING THE SAFE USE AND/OR OPERATION OF THIS TOOL, CONSULT YOUR AREA SUPERVISOR, OR CONTACT RELIABLE EQUIPMENT AT 800-966-3530...
  • Page 10 ELECTRICAL SHOCK HAZARD Always wear and use the necessary clothing, equipment and safety practices to protect against electrical shock. Failure to follow these rules can result in serious personal injury or death. WARNING GENERAL SAFETY USE ALL APPROPRIATE AND APPLICABLE PERSONAL SAFETY EQUIPMENT as required by the operating company.
  • Page 11: Hydraulic System Requirements

    HYDRAULIC SYSTEM REQUIREMENTS Operating Pressure: 1200-2000 PSI (70-140 bar) Max. Relief Setting: 2100 psi (145 bar) Flow Range: 5-9 gpm 7-10 gpm (26-45 lpm) REL-TP3 REL-TP4 Max. Backpressure: 250 psi (17 bar) Cooling System: Required Min. Filtration: 25 Micron Sound Pressure <85 dBA @ 1m Hydraulic Fluids: All hydraulic fluids that meet these listed specifications...
  • Page 12: Operating Instructions

    OPERATION PRE-OPERATION Do not use this tool under unsafe working conditions or locations. Use this pump only for it’s intended purpose. This pump is not designed for operation with a suction pipe inlet. Read entire manual prior to operation of this tool. (Refer to all safety recommendations and warnings) Observe all safety precautions &...
  • Page 13: Daily Maintenance & Labels

    DAILY MAINTENANCE IMPORTANT: The greatest cause of hydraulic system failure is dirt. Prevent the introduction of foreign matter into the pump via hydraulic fl uid, dirty connections or accumulation of sediment in the hydraulic system. The life, reliability, and safety of the tool is dependent on proper maintenance. Maintenance must be performed by authorized and trained personnel ONLY.
  • Page 14: Troubleshooting & Repair Intro

    Increasing Flow May Remove Excess Solids, but may result in wear or damage to the pump. IF THE ISSUE OR THE PROPER SOLUTION IS NOT FOUND ABOVE CONTACT YOUR RELIABLE SERVICE REPRESENTATIVE WARNING: ALL tool repair and service must be performed by authorized and trained personnel ONLY.
  • Page 15 REL-TP3 HYDRAULIC SUBMERSIBLE TRASH PUMP REL-TP3 PARTS LIST Description TP305 Urethane Volute TP307 Base TP306 Urethane Impeller TP321 Gasket TP317 Motor Mount Plate TP304 Motor FF-370 FF Coupler Set TP319 Carry Handles TP301 Wing Nut 10 TP318 Cam Loc 3” Male 11 TP315 Motor Mounting Nuts 12 TP303...
  • Page 16: Visual Warnings

    REL-TP4 HYDRAULIC SUBMERSIBLE TRASH PUMP REL-TP4 PARTS LIST Description TP401 Volute TP402 Impeller TP403 Motor Assembly TP404 Woodruff Key TP405 Washer TP406 Impeller Nut TP407 Motor Plate TP408 Plate Bolt TP409 Plate / Shoe Washer 10 TP410 Plate / Shoe Lock Washer 11 TP411 UHMW Wear Plate 12 TP412...
  • Page 17: Operation Records

    OPERATION RECORDS Date Hours Liquid Type Solid Type & Concentration Flow Head...
  • Page 18 RELIABLE EQUIPMENT Protective Foot Wear at the address, phone or fax numbers shown below. Electrical Shock 301 Ivyland Road • Warminster, PA 18974 Hot Surfaces Phone: 800-966-3530 • Fax: 215-357-9193 Visit us on the web at www.Reliable-Equip.com Hydraulic Injection...

This manual is also suitable for:

Rel-tp3Rel-tp4

Table of Contents