Western Co Leonardo OFF-GRID 8kW/8000/48 GE User Manual

Hide thumbs Also See for Leonardo OFF-GRID 8kW/8000/48 GE:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Leonardo Off-Grid
8kW-8000-48 GE
IT
Manuale utente
EN
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Leonardo OFF-GRID 8kW/8000/48 GE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Western Co Leonardo OFF-GRID 8kW/8000/48 GE

  • Page 1 Leonardo Off-Grid 8kW-8000-48 GE Manuale utente User manual...
  • Page 3 Gruppo Elettrogeno della abitazione fino al suo completo auto-sostentamento.  Interruttore di sezionamento batteria Il Leonardo Off-Grid 8kW/8000/48 GE e de fa ile ed i ediato l’utilizzo di e e gia p odotta da oduli fotovoltai i, pe l’ali e tazio e di ute ze ...
  • Page 4: Istruzioni Di Sicurezza

    Leonardo Off-Grid 8kW/8000/48 GE Manuale utente Istruzioni di sicurezza Pericolo di esplosione a causa di scintille Pericolo di folgorazione ATTENZIONE: non sollevare oggetti pesanti senza assistenza Generale  Si consiglia di leggere attentamente questo manuale prima di installare e utilizzare il prodotto.
  • Page 5: Manuale Utente

    Manuale utente FUNZIONAMENTO DEL LEONARDO OFF-GRID 8kW/8000/48 GE Il Leonardo Off-Grid 8kW/8000/48 GE è progettato per ottenere un risparmio e e geti o di etto t a ite l’utilizzo di energia fotovoltaica ed altre fonti rinnovabili; l'impianto fotovoltaico viene gestito tramite il regolatore di carica con n.4 ingressi MPPT indipendenti;...
  • Page 6 Leonardo Off-Grid 8kW/8000/48 GE Manuale utente SCHEMA INTERNO LEONARDO DATA-LOGGER GRUPPO ELETTROGENO CONTATTO OUT1 ACCENSIONE AUTOMATICA IMPIANTO RELE' DOMESTICO APERTURA PRILEGIATO INGRESSO INVERTER OFF-GRID 230Vac ENERGY 230Vac ISOLATO MANAGER CAMPO FV BATTERIA BATT REGOLATORE LEONARDO OFF-GRID MPPT 4-INPUT Fig.3 Schema interno...
  • Page 7 Leonardo Off-Grid 8kW/8000/48 GE Manuale utente SCHEMA DI COLLEGAMENTO INVERTER DC/AC - Potenza continua 8000 VA - Potenza di sovraccarico 7000W - Ingresso AC - Batteria 48Vdc CAMPO FV - 4 ingressi MPPT indipendenti - Potenza max 8 kWp - Potenza max singolo ingresso 2 kW - 4 stringhe da 2x3 o 2x4 moduli FV da 60 celle, es.
  • Page 8 PROTEZIONI ESTERNE Protezioni lato Corrente Alternata Il Leonardo Off-Grid 8kW/8000/48 GE è dotato di una linea di uscita in corrente alternata AC-OUT ed una linea di ingresso in corrente alternata AC-IN. Essendo l'apparecchio dotato di collegamento a terra del conduttore NEUTRO - sistema TT, la linea di uscita in corrente alternata AC-OUT può...
  • Page 9 SEZIONE REGOLATORI DI CARICA FOTOVOLTAICA Il Leonardo Off-Grid 8kW/8000/48 GE è dotato di regolatore di carica FV con 4 ingressi MPPT indipendenti: è un regolatore di carica da moduli fotovoltaici per batterie elettrochimiche al piombo di tipo OPzV o OPzS.
  • Page 10 Manuale utente SEGNALAZIONI ESTERNE Sul lato laterale del Leonardo Off-Grid 8kW/8000/48 GE sono presenti le segnalazioni di funzionamento dell’i ve te : Inverter Mode e Bypass Mode, lo stato di carica della batteria, la potenza assorbita dal carico, lo stato del carica da fotovoltaico e la presenza della rete AC dal gruppo elettrogeno.
  • Page 11 Leonardo Off-Grid 8kW/8000/48 GE Manuale utente LOGICA DI FUNZIONAMENTO Home Consumption PV Production Genset Power Battery Power Fig.10 Logica di funzionamento Tabella Stato di carica e potenza di uscita Stato di carica SOC livello 4, l'energia effettivamente stoccata in batteria si...
  • Page 12: Installazione E Cablaggio

    RESET presente alla base dell'apparecchio (Fig. 12). INSTALLAZIONE E CABLAGGIO a) Installare il Leonardo Off-Grid 8kW/8000/48 GE in un luogo asciutto ed adeguatamente arieggiato, fissato su di una superficie non infiammabile e posizionato in modo da lasciare uno spazio privo di ostacoli di almeno 10cm ell’i to o del dispositivo he e pe...
  • Page 13 Leonardo Off-Grid 8kW/8000/48 GE Manuale utente 5. collegare ingresso AC-IN su connessione AC Input tramite connettori AC plug and play tipo RST (se presente il gruppo elettrogeno); 6. collegare uscita AC-OUT su connessione AC Output tramite connettori AC plug and play tipo RST 7.
  • Page 14 Leonardo Off-Grid 8kW/8000/48 GE Manuale utente CABLAGGIO - CONTATTO DI ACCENSIONE AUTOMATICA GRUPPO ELETTROGENO I prodotti della serie Leonardo Off-Grid GE, modelli 1kW/1500/24, 4kW/3000/48, 4kW/5000/48 e 8kW/8000/48, hanno la gestione di un contatto ausiliario pulito, per il collegamento di un gruppo elettrogeno di emergenza con dispositivo di accensione automatica, collegato all'ingresso AC INPUT.
  • Page 15 Appena realizzati i collegamenti come in Fig.12 è necessario procedere avviamento e collaudo del sistema: 1) ve ifi a e l’a e sio e del Leonardo Off-Grid 8kW/8000/48 GE al termine del collegamento dei cavi sui morsetti della batteria ed attivazione dell'interruttore di sezionamento batteria;...
  • Page 16 Leonardo Off-Grid 8kW/8000/48 SL Manuale utente Schema Unifilare dell'impianto trifase 24kW. Fig.14 Schema Unifilare dell'impianto trifase 24Kw...
  • Page 17 Leonardo Off-Grid 8kW/8000/48 SL Manuale utente Impianto Trifase tot. 48kW: Fase L1  n.1 Master + n.1 Slave - Fase L2  n.2 Slave - Fase L3  n.2 Slave INVERTER MASTER L1 INVERTER SLAVE L2 INVERTER SLAVE L3 A - Plug Datalogger A - Plug Sincronismo A - Plug Sincronismo B - Plug Sincronismo...
  • Page 18 Leonardo Off-Grid 8kW/8000/48 Manuale utente CARATTERISTICHE MECCANICHE E PESO Leonardo Off-Grid 8kW/8000/48 GE = 55 kg Fig.17 Caratteristiche meccaniche...
  • Page 19: Caratteristiche Elettriche

    Leonardo Off-Grid 8kW/8000/48 Manuale utente CARATTERISTICHE ELETTRICHE Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid 1kW / 1500 / 24 GE 4kW / 3000 / 48 GE 4kW / 5000 / 48 GE 8kW / 8000 / 48 GE Potenza di uscita Pout 1.500VA 3.000W 3.000VA 6.000W...
  • Page 20: Smaltimento Dei Rifiuti

    Il prodotto difettoso dovrà essere rispedito alla Western CO. Srl o a società delegata dalla Western CO. Srl a fare assistenza sul prodotto, a spese del cliente, assieme ad una copia della fattura di vendita, sia per la riparazione che la sostituzione garantita.
  • Page 21  Lead Batteries for cyclic use OPzS, house until it is fully self-sustaining. OPzV Leonardo Off-Grid 8kW/8000/48 GE makes it easy and immediate the use  Low battery protection of energy produced by photovoltaic modules, for the supply of domestic consumptions, with the possibility of using a genset (back-up) in case of ...
  • Page 22: Safety Instructions

    Leonardo Off-Grid 8kW/8000/48 GE User Manual Safety instructions Danger of explosion from sparking Danger of electric shock WARNING: do not lift heavy objects unassisted. In general  Read the installation instructions before commencing installation activities.  The product installation and maintenance must be performed only by qualified personnel.
  • Page 23 User Manual LEONARDO OFF-GRID 8kW/8000/48 GE WORKING PRINCIPLES Leonardo Off-Grid 8kW/8000/48 GE is designed to achieve direct energy savings through the use of photovoltaic energy and other renewable sources; the photovoltaic system is managed by the charge controller with 4 independent MPPT inputs;...
  • Page 24: Internal Diagram

    Leonardo Off-Grid 8kW/8000/48 GE User Manual INTERNAL DIAGRAM LEONARDO DATA-LOGGER GRUPPO ELETTROGENO CONTATTO OUT1 ACCENSIONE AUTOMATICA IMPIANTO RELE' DOMESTICO APERTURA PRILEGIATO INGRESSO INVERTER OFF-GRID 230Vac ENERGY 230Vac ISOLATO MANAGER CAMPO FV BATTERIA BATT REGOLATORE LEONARDO OFF-GRID MPPT 4-INPUT Pic.3 Internal diagram...
  • Page 25: Connection Diagram

    Leonardo Off-Grid 8kW/8000/48 GE User manual CONNECTION DIAGRAM DC / AC INVERTER - Continuous Power 8000 VA PV FIELD - 7000W overload power - 4 independent MPPT inputs - AC input - Max power 8 kWp - 48Vdc Battery - Max single input power 2 kW - 4 strings of 2x3 or 2x4 PV modules of 60 cells, ex.
  • Page 26: External Protection

    EXTERNAL PROTECTION Protections for Alternating Current side Leonardo Off-Grid 8kW/8000/48 GE is equipped with an AC-OUT alternating current output line and an AC-IN alternating current input line. Since the device has a conductor connected to the NEUTRAL - TT system, the AC output line AC-OUT can be protected with a thermal-magnetic circuit breaker AC type, with nominal current In = 32A and differential current Id = 0.03 (usually...
  • Page 27 User Manual PHOTOVOLTAIC CHARGE CONTROLLER SECTION Leonardo Off-Grid 8kW/8000/48 GE is equipped with PV charge controller with 4 independent MPPT inputs: is a charge controller for photovoltaic modules for lead electrochemical batteries of the OPzV or OPzS type. For the correct recognition of the battery voltage performed at power up, it accordingly sets the appropriate charging parameters as described in Tab.1.
  • Page 28: External Signals

    EXTERNAL SIGNALS On the lateral side of Leonardo Off-Grid 8kW/8000/48 GE there are the working reports of the inverter: Inverter Mode - By-pass Mode, the status of the battery charge, the power absorption of the load, the status of the photovoltaic charge and the presence of the AC grid in input.
  • Page 29: Operating Logic

    Leonardo Off-Grid 8kW/8000/48 GE User Manual OPERATING LOGIC Home Consumption PV Production Genset Power Battery Power Pic.10 Operating logic Charge status and output power table SOC charge status level 4, the actually stored energy in the battery is in an...
  • Page 30: Installation And Wiring

    INSTALLATION AND WIRING a) Install Leonardo Off-Grid 8kW/8000/48 GE in a dry and adequately ventilated place, fixed on a non-combustible surface and positioned in order to have a space free of obstacles of at least 10 cm around the device so to have the cooling by forced air convection.
  • Page 31 Leonardo Off-Grid 8kW/8000/48 GE User Manual 5. connect input AC-IN on AC Input connection through plug and play type RST AC connectors (if the genset is present); 6. connect AC-OUT output on AC Output connection via plug and play type RST AC connectors 7.
  • Page 32 Leonardo Off-Grid 8kW/8000/48 GE User Manual WIRING - GENSET AUTOMATIC IGNITION CONTACT The products of the Leonardo Off-Grid GE series, models 1kW/1500/24, 4kW/3000/48, 4kW/5000/48 and 8kW/8000/48, have the management of a clean auxiliary contact, for the connection of a genset with automatic ignition device connected to the AC INPUT input.
  • Page 33: Possible Problems And Solutions

    As soon as the connections are made as in Pic.12 it is necessary to start and test the system: 1) check the switching on of the Leonardo Off-Grid 8kW/8000/48 GE at the end of the cable connection on the battery terminals and activation of the battery isolation switch;...
  • Page 34 Leonardo Off-Grid 8kW/8000/48 SL User manual Single-phase diagram of the 24kW three-phase system. Pic.14 Single line diagram of the 24Kw three-phase system...
  • Page 35 Leonardo Off-Grid 8kW/8000/48 SL User Manual Three Phase System tot. 48kW: Phase L1  n.1 Master + n.1 Slave - Phase L2 No.  2 Slave - Phase L3 No.  2 Slave INVERTER MASTER L1 INVERTER SLAVE L2 INVERTER SLAVE L3 A - Datalogger Plug A - Synchronous Plug A - Synchronous Plug...
  • Page 36 Leonardo Off-Grid 8kW/8000/48 User Manual MECHANICAL FEATURES AND WEIGHT Leonardo Off-Grid 8kW/8000/48 GE = 55 kg Pic.17 Mechanical features...
  • Page 37: Electrical Features

    Leonardo Off-Grid 8kW/8000/48 User Manual ELECTRICAL FEATURES Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid 1kW / 1500/24 GE 4kW / 3000/48 GE 4kW / 5000/48 GE 8kW / 8000/48 GE Output power Pout 1,500VA 3,000W 3,000VA 6,000W 5,000VA 10,000W 8,000VA 16,000W Battery Voltage Vbatt...
  • Page 38: Warranty

    5 (five) years, to repair or replace at its sole discretion, for free, those defective parts owing to poor quality of material or defect in workmanship. The defective product must be returned to Western Co. Srl or to the company delegated by Western Co to make produ t support, at usto er’s e pe ses, together...
  • Page 39 Questo documento è di proprietà di WESTERN CO. Srl - Tutti i diritti sono riservati - La riproduzione e l'uso delle informazioni contenute nel presente documento sono vietati senza il consenso scritto di WESTERN CO. Srl. This document is the property of WESTERN CO. Srl - All rights are reserved - Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO.

Table of Contents