Download Print this page
Dometic DF Series Operating Instructions Manual

Dometic DF Series Operating Instructions Manual

Hide thumbs Also See for DF Series:

Advertisement

Models DFSAD12, DFSD12, DFSD16, DFSD20, DFMD16,
DFMD20, DFMD25, DFMD30, DFMD35, DFLD35,
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
IMPORTANT SAFETY INSTRUCTIONS AND DOCUMENT SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSPECTION AND MONTHLY MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ANNUAL MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Read these instructions carefully. These instructions MUST stay with this product.
Form No. 33401 09/17
©2017 Dometic Corporation
LaGrange, IN 46761
DF Series Furnace
DFLD40, DFLA35, DFLA40
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death or property damage.
− Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
− WHAT TO DO IF YOU SMELL GAS
• Evacuate all persons from the vehicle.
• Shut off the gas supply at the gas container or source.
• Do not touch any electrical switch, or use any phone or radio
in the vehicle.
• Do not start the vehicle's engine or electric generator.
• Contact the nearest gas supplier or qualified service
technician for repairs.
• If you cannot reach a gas supplier or qualified service
technician, contact the nearest fire department.
• Do not turn on the gas supply until the gas leak(s) has been
repaired.
− Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
OPERATING
INSTRUCTIONS
USA & CANADA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
SERVICE CENTER &
DEALER LOCATIONS
Visit:
www.eDometic.com

Advertisement

loading

Summary of Contents for Dometic DF Series

  • Page 1: Table Of Contents

    OPERATING INSTRUCTIONS DF Series Furnace Models DFSAD12, DFSD12, DFSD16, DFSD20, DFMD16, DFMD20, DFMD25, DFMD30, DFMD35, DFLD35, DFLD40, DFLA35, DFLA40 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IMPORTANT SAFETY INSTRUCTIONS AND DOCUMENT SYMBOLS .
  • Page 2: Introduction

    INTRODUCTION This manual is intended for reference on the safe operation and maintenance of the Dometic DF Series Furnace . Should you require further information, contact Dometic . This DF Series Furnace (hereinafter referred to as “Furnace”) has been certified and designed as an MSP Category III Furnace and is intended for use inside a recreational vehicle (hereinafter referred to as “RV”) .
  • Page 3 • Shut OFF the gas valve to the Furnace before shutting off the electrical supply if the gas supply fails to shut off, or if overheating occurs . • Use only Dometic replacement parts and components, which are specifically approved for use with the Furnace . • CRITICAL OPERATION WARNINGS: •...
  • Page 4: Operation

    OPERATION  FIRE OR EXPLOSION HAZ ARD . Failure to obey the following warnings could result in property damage, serious injury, or death: • This Furnace does not have a pilot . It is equipped with an ignition device that automatically lights the burner . Do NOT try to light the burner by hand .
  • Page 5: Inspection And Monthly Maintenance

    OPERATION B. Turning Off The Furnace FIG. 1 FIG. 2 Power Switch *Power Switch Furnace Furnace (Small Vent) (Door Model) Thermostat Thermostat *Switch is located behind door • Set the thermostat to the lowest setting, then turn to the OFF position . •...
  • Page 6 INSPECTION AND MONTHLY MAINTENANCE B. Inspecting The Vents And Exhaust Tubes FIG. 1 FIG. 2 Exhaust Tube Cleaning Exhaust Vent Brush • Inspect the Furnace venting . Confirm the vents properly • Inspect the Furnace exhaust tubes for blockage, overlap, expel exhaust into the atmosphere and that the vent holes, or soot .
  • Page 7: Annual Maintenance

    Furnace . Failure to obey this warning could result in dangerous operation, property damage, serious injury, or death: • For replacement part information, see the DF Series Furnace Parts List . For the most current information, visit www .eDometic .com .
  • Page 8 (f) failure to follow Seller’s instructions for use of this Dometic Product; (g) any accident to, or misuse of, any part of the Dometic Product and any alteration by anyone other than the Seller or its authorized representative;...