Set up an inverter drive kit RPM Hz (when DI contact point is used)
• Tact SW use explanation
• Check menu: (enter into set up menu and fix parameter value)
• Move around menu: (move left and right / select 0~9)
• Cancel menu: X (move to the previous menu)
- When the setup is completed, the set up value blinks three times and stops to finalized the
set up value.
• Parameters to be set up (set up by 1 Hz unit)
1. Low wind frequency set up(range: 20~medium wind set up value Hz)
- Default: 30 Hz
2. Medium wind frequency set up (range: low wind set up value ~ strong wind set up value Hz,
set up by 1 Hz unit_
- Default: 40 Hz
3. Strong wind frequency set up
- Default: 50 Hz (range: medium wind set up value~60 Hz, set up by 1 Hz unit)
4. Error checking mode
- shows the three most recent error in series