Download Print this page

Extreme Networks ERS 5900 Series Quick Install Manual page 2

Ethernet routing switch

Advertisement

6
Powering Up
You can install an AC power supply into either power supply slot in
the switch.
The airflow direction of the power supply in PS1 determines the
primary airflow direction for the switch. If PS1 is not present, PS2
determines the airflow direction. If any power supply location is
unpopulated, a PSU Filler Panel must be installed.
1. Insert the first power supply into the rear PS1 power supply slot. If a
blanking plate covers the required power supply slot, remove the
plate before inserting the power supply. A small angle on the top
corner of the power supply ensures that the power supply can only
be installed in one orientation in the switch.
2. Verify that the power supply is fully seated in the slot and securely
clipped in place.
3. Optional: Install the second power supply into the rear PS2 power
supply slot. The airflow direction must match the primary Power
Supply. The switch ships with a filler panel in PS2 position. Leave
the filler panel in place if you do not install a second power supply.
PS2
PS1
Warning: You must use a power cord set approved for the ERS 5900
Series switch and the power receptacle type in your country. Ensure
you have properly grounded the switch before powering up the unit.
The switch will power on immediately when it is connected to a
suitable AC power source. The switch does not have a power switch.
Check the front-panel LEDs as the device powers on to be sure the
PWR LED is lit. If not, check if the power cord is correctly
connected.
Check LED status of the fans and power supplies. Status LEDs are on
the left front side of the switch. For more information on all status
LEDs, see Installing ERS 5900 Series.
Your Setup
All Setups
Status LED (Blinks)
Green until agent
Base
Status
software is loaded, then
Up
Down
goes (Solid) Green
Front to Back
Fan1 – Blue (Solid)
Fans
Fan2 – Blue (Solid)
Fan1
Fan2
Back to Front
Fan1 – Violet (Solid)
Fan1
Fan2
Fans
Fan2 – Violet (Solid)
One Power
PS1 – Green (Solid)
Supply
PS2 – Off
PS1
PS2
Two Power
PS1 – Green (Solid)
PS1
PS2
Supplies
PS2 – Green (Solid)
7
Install SFP and SFP+ transceivers
Before installing, ensure the switch is up and running, and operating
normally. Verify that the SFP or SFP+ transceivers and network cabling
support your network configuration. Note: The ERS 5900 supports
Hot-Swapping of SFP and SFP+ transceivers and direct attach cables.
1. If you are installing SFP direct attach cables, remove packaging, insert
the transceiver connector into a switch port and insert the opposite end
into the SFP port of the corresponding network device.
OR
If you are installing SFP or SFP+ optical transceivers, remove packaging
and insert the pluggable transceiver connector into a switch port.
2. Remove the network interface cover from the transceiver connector
(if applicable) and insert an appropriate network interface cable into
the transceiver.
3. Connect the opposite end of the network interface cable to your network.
4. In both cases, ensure that the device clicks and locks into place.
Commissioning the ERS 5900
1
Connect the console cable to the ERS 5900
The console port is the RJ-45 port shown with a blue border outline on
the front of your ERS 5900 Series switch (note orientation). Use the
console cable (AL2011022-E6) to connect the switch console port to
your management terminal. The maximum length of a console cable is
25 feet (8.3 meters). The following table describes the RJ-45 console
port pin-out information. You can use the pin-out information to verify
or create a console cable for use with your maintenance terminal.
Connector
Pin Number
Signal
1
RTS (ready to send) — optional
2
DTR (data terminal ready) — optional
3
TXD (transmit data) — mandatory
4
GND (ground) — mandatory
5
DCD (carrier detect) — optional
6
RXD (receive data) — mandatory
7
DSR (data set ready) — optional
8
CTS (clear to send) — optional
1. Connect the console cable from the terminal to the console port of the
switch to allow initial configuration. Any terminal or PC with the
appropriate terminal emulator can be used as the management station.
2. Set the terminal protocol on the terminal or terminal emulation
program to VT100 or VT100/ANSI.
3. Connect to the switch using the terminal or terminal emulation
application.
4. The switch banner appears when you connect to the switch through
the Console port. There is no default password for the switch for CLI
console access. Enter Ctrl+Y and type the following CLI commands:
enable
install
Note: Extreme Networks provides two console cable options to
connect the ERS 5900's DB9 (m) to a standard Pc/Laptop DB9 (m).
1. A 1.5 m integrated RJ45/DB9 (f) Console Cable (AL2011022-E6) in
conjunction with a DB9(f)/RJ45 Adapter (AL2011020-E6)
OR
2. Two DB9(f)/RJ45 Adapter (AL2011020-E6) connected together
using a standard Cat5e Ethernet Cable (purchased separately)
Terminal emulation settings
Property
Value
Baud Rate
9600 bps
Data Bits
8
Stop Bits
1
Parity
None
Flow Control
None
2
The CLI Quickstart welcome screen helps you enter the
information requested at each prompt.
Note: The ERS 5900 uses the default IP address of 192.168.1.1/24 if the
switch does not get its IP address from another source.
Note: the default IP address is not applicable to the out-of-band
management port.
###########################################################################
Welcome to the 5952GTS-PWR+ setup utility.
You will be requested to provide the switch basic connectivity settings.
After entering the requested info, the configuration will be applied and
stored into the switch NVRAM.
Once the basic connectivity settings are applied, additional configuration
can be done using the available management interfaces.
Use Ctrl+C to abort the configuration at any time.
###########################################################################
Please provide the Quick Start VLAN <1-4094> [1]:
Please provide the in-band IP Address[192.0.2.1]:
Please provide the in-band sub-net mask[255.255.255.0]:
Please provide the Default Gateway[192.0.2.1]:
Please provide the management sub-net mask[0.0.0.0]:
Please provide the management IP Address[0.0.0.0]:
Please provide the management Default Gateway[0.0.0.0]:
Please provide the Read-Only Community String[**********]:
Please provide the Read-Write Community String[**********]:
Please provide the in-band IPV6 Address/Prefix_length[::/0]:
Please provide the in-band IPV6 Default Gateway[::]:
Please provide the management IPV6 Address/Prefix_length[::/0]:
Please provide the management IPV6 Default Gateway[::]:
###########################################################################
Basic stack parameters have now been configured and saved.
###########################################################################
Command Line Interface (CLI)
You can manually load the CLI script from the console menu or
automatically load the script at startup.
Command
Description
Entrance
Exit
Mode
Commands
Commands
exit
User Executive
• Default and Initial access mode
No entrance
(Exec mode)
• Requires only Read access
command, default
or
logout
5900>
• Used for basic commands
mode
such as show, ping, and logoff
enable
exit
Privileged EXEC
• Used for basic switch level
or
(PrivExec mode)
management tasks; e.g.,
logout
5900#
downloading software
images, setting passwords,
starting the switch
• Default and Initial access mode
• Requires only Read access
exit
Global
• Used to set and display general
From Privileged
or
Configuration
switch parameters such as IP
EXEC mode, enter:
logout
configure
(Config mode)
address, ANMP parameters,
5900(config)#
Telnet access and VLANs
• Requires Read-Write access
Interface
• Used to configure
From Global
To return to Global
Configuration
parameters for each port or
Configuration mode, to
Configuration mode,
(ifconfig mode)
VLAN such as speed, duplex
configure a port, enter:
enter:
5900(config-if)#
mode, and rate limiting
exit
interface ethernet
• Requires Read-Write access
<port_number>
To return to Privileged
EXEC mode, enter:
To configure a VLAN,
end
enter:
To exit ACLI completely,
interface vlan
enter:
<vlan_number>
logout
To configure a
loopback, enter:
interface loopback
<loopback number>.
To configure a
management, enter:
interface mgmt
<mgmt number>
For more information on additional modes, see Using CLI and EDM on
ERS 5900 Series.
Manual Configuration
You can manually configure the in-band management IP address at any
time with the following CLI command:
ip address <A.B.C.D> [netmask <A.B.C.D>] [default-gateway <A.B.C.D>]
Example:
1. Enter Privileged Exec mode:
Switch>enable
2. Enter the Global Config mode:
#config terminal
3. Manually configure in-band management IP information:
Switch(config)#ip address 192.0.2.1 netmask 255.255.255.0
default-gateway 192.0.2.0
4. Verify the information
Switch(config)#show ip
Bootp/DHCP Mode: BootP When Needed
Configured
In Use
Last BootP/DHCP
------------- ------------
---------------
Stack IP Address:
0.0.0.0
0.0.0.0
Switch IP Address:
192.0.2.1
192.0.2.1
0.0.0.0
Switch Subnet Mask:
255.255.255.0 255.255.255.0 0.0.0.0
Mgmt Stack IP Address:
0.0.0.0
Mgmt Switch IP Address: 0.0.0.0
Mgmt Subnet Mask:
0.0.0.0
Mgmt Def Gateway:
0.0.0.0
Default Gateway:
192.0.2.0
192.0.2.0
0.0.0.0
CLI boot and factory-default commands:
boot - reboot the switch
boot default - reboot and use the factory default configuration
boot partial-default - reboot and use the partial factory default
configuration
restore factory-default - reset the switch to factory default
configuration
General notes
• The micro-USB port on the front panel of the ERS 5900 is
not enabled
• The SDN port on the rear panel of the ERS 5900 is not enabled
Recommended reading
To obtain additional documentation references, go to
http://www.extremenetworks.com/support/documentation/
and download the following:
• Locating Documentation
• Documentation Reference
• Installing ERS 5900
• Installation Job Aid
• Release Notes
6480 Via Del Oro
San Jose, CA 95119
Tel: +1 408-579-2800
Toll-free: +1 888-257-3000
WWW.EXTREMENETWORKS.COM
Poster part number: 700510898 Rev.06
NN47211-303 04.07

Advertisement

loading

This manual is also suitable for:

Ers 5928gts-upwrErs 5928gtsErs 5928gts-pwr+