Page 1
OPERATING INSTRUCTIONS AND REPLACEMENT PARTS Models: CVF-8AC, CVF-8AC50, CVF-6ACAN, CVF-15ACAN, CVF-25ACAN CVF-8DC, CVF-6DCAN, CVF-15DCAN, CVF-25DCAN WArNiNG this manual must be read carefully and followed by all persons who have or will have the responsibility for using or servicing this equipment. this equipment will perform as designed only if used according to the instructions.
Page 2
Att ach all grounding wires and assure a complete circuit to the blower or fan in order to remove stati c charges. The Saddle Vent® is a registered trademark of Air Systems Internati onal, Inc. The Conducti ve Saddle Vent® is covered by U.S. and Foreign Patents...
Model No. CVF-8EXP or Air Systems’ intrinsically safe pneumati c blower, Model No. SVB-A8. Note: For confi ned space venti lati on in non-hazardous locati ons, use Air Systems’ confi ned space venti lati on kit, Model SV-CUP. For hazardous locati ons use venti lati on kit, Model SV-...
General Set-Up and operation For CVF-8AC, CVF-8AC50, and CVF-8DC Models 1) Place fan in a clean fresh air environment. 2) Air quality of the confined space should be tested prior to ventilation. If air quality of the confined space is unacceptable, consult a trained professional.
System Components - AC Voltage Contractor Fans Models: CVF-8AC Series ® iteM # DeSCriPtioN PArt # DISCHARGE GUARD CVF-FG INTAKE GUARD CVF-RG DUCT CANISTER LATCHING POST CVF-PoST ON/OFF SWITCH CVF-SWITCH POWER CORD ELCB012 DUCT CANISTER WITH 6’ OF DUCT CVF-CAN6 DUCT CANISTER WITH 15’...
Page 6
INTAKE GUARD CVF-RG DUCT CANISTER LATCHING POST CVF-PoST ON/OFF SWITCH CVF-SWITCH CVF-8AC50 POWER CORD (“E+F” STYLE PLUG)(CEE 7/7) ELCB012EF CVF-8AC50G POWER CORD (“G” STYLE PLUG)(BS1363 UK) ELCB012G DUCT CANISTER WITH 6’ OF DUCT CVF-CAN6 DUCT CANISTER WITH 15’ OF DUCT CVF-CAN15 DUCT CANISTER WITH 25’...
Page 7
System Components - DC Voltage Contractor Fans Models: CVF-8DC Series iteM # DeSCriPtioN PArt # DISCHARGE GUARD CVF-FG 12 VDC ELECTRIC MOTOR MTR044CN FAN BLADE ASSEMBLY CVF-FAN INTAKE GUARD CVF-RG 20 AMP SLOW BLOW FUSE ELF022 DUCT CANISTER LATCHING POST CVF-PoST ON/OFF SWITCH CVF-SWITCH...
Page 8
System Components - Non-Conductive Duct Canister Models: CVF-CAN Series iteM # DeSCriPtioN PArt # RUBBER LATCH CVF-RHOOK RUBBER LATCH SECURING HOOK CVF-UPoST 10-32 X 1” SCREW FS1032X100 10-32 X 1/2” SCREW FS1032X050 RED DUCT CANISTER, NON-CONDUCTIVE CVF-CAN-ND RED DUCT ADAPTER, NON-CONDUCTIVE CVF-CANA 8”...
Air Systems’ manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for one year from the date of purchase. Any part which is determined by Air Systems to be defective in mate- rial or workmanship will be, as the exclusive remedy, repaired or replaced at Air Systems’...