Suspended Solids Input Card Connection Details
Suspended Solids Input Connector
Unit Earth Terminal
Green
Black
Brown
Yellow
Cable Screen
Red
White
Orange
S10, S20, S40 Suspended Solids Sensor Cable
Connection Details
User Interface Overview
4-20mA
Digital
Error
Outputs Setup
Inputs Setup
Messages
ALARM STATUS
SETPOINT STATUS
SETPOINT STATUS
LEDS
LEDS
LEDS
UNIT STATUS
CURRENT DATE
517.2
09:56
MON 1 JUN 2009
CHANNEL PRIMARY
TANK 1
CURRENT TIME
READING
CH1:
µS/cm
12.3
°C
ii)
A:12.28
mA
CHANNEL SECONDARY
CHANNEL SECONDARY
i)
9.64
READING ii
READING i
DOSE ALARM
pH
CHANNEL
CH2:
CHANNEL ALARM
25.0
-156mV
MESSAGES
i)
°C
ii)
STATUS
23.3
TANK 3
CH3:
%
28.0
°C
50.15
µS/cm
CHANNEL
CHANNEL ID
i)
ii)
LABEL
ACK
CAL
MENU
CONTEXT SENSITIVE BUTTON FUNCTIONS
Front Layout
For con guration and calibration information please consult the operational manuals
on the accompanying CD.
Turbidity Input Card Connection Details
Turbidity Input Connector
Unit Earth Terminal
Green
Black
Brown
Yellow
Blue
Red
White
Orange
T30 Turbidity Sensor Cable
Connection Details
Current
Live Trends
Channels
Front Screen
Output
1, 2 & 3*
Setup
Bargraphs
*Optional Extra
Scrolling Menu Layout
CURRENT
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
DATE / TIME
INSTRUMENT
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
CH3: 23.3%
TEMP3: 28.0°C
READINGS
UNIT STATUS
MAIN MENU
FURTHER MENU
CURSOR
CHANNELS
PAGES ABOVE
CALIBRATION
SETPOINT / RELAYS
4-20mA OUTPUTS
FURTHER MENU
DIGITAL INPUTS
PAGES BELOW
CONFIGURATION
EXIT
Main Menu Layout
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
CH3: 23.3%
TEMP3: 28.0°C
SETPOINT 1 SETUP
OPTION POP-UP
CHANNEL:
CHANNEL 1 (COND)
TRIGGER
INPUT SOURCE:
SENSOR
HIGH
RANGE:
0 to 9.999 mS/cm
CURSOR
LOW
TRIGGER:
HIGH
BAND
ADDITIONAL
HIGH VALUE:
7.500mS/cm
LATCH HIGH
OPTIONS BELOW
MODE:
ON/OFF
LATCH LOW
EXIT
The default Access Code is: 1000
Pop-Up Option Layout
MXD73
Quick Start Guide
MXD73 Instrument Dimensions
Cable Screen
MON 1 JUN 2009
517.2
CH1:
12.3
i)
°C
9.64
CH2:
pH
i)
25.0
°C
23.3
128 mm
CH3:
%
28.0
°C
i)
CAL
Setpoint /
Relays Setup
F1
F2
116 mm
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
CH3: 23.3%
TEMP3: 28.0°C
CHANNEL 1 SETUP
MODE:
ON-LINE
SECURITY CODE
Power & Standard Outputs Connection Details
UNITS:
ENTER ACCESS
SIEMENS(S/cm)
CODE
CELL CONSTANT:
1.000
0
* * *
CAUTION!
RANGE:
AUTO
Always remove the main power from the system
TEMP INPUT SENSOR:
PT1000
before any alterations to the wiring. Ensure that
TEMPERATURE UNITS:
°C
both power lines are isolated. Make sure that the
EXIT
power cannot be switched on by accident whilst the
Security Access Pop-Up
instrument is being connected. For safety reasons
an earth connection must be made to the earth
To protect the instrument setup
terminal of this instrument.
from unauthorised or accidental
tampering, a security access code
Local wiring and safety regulations should be strictly
system is present. This is
adhered to when installing this instrument. If the
implemented via the instrument's
installation methods and cable types recommended
menu system which operates in two
in this guide are followed, then the instrument will
modes, "locked" as indicated by a
achieve the levels of EMC protection as speci ed in
padlock
symbol and "unlocked" as
the accompanying CD manual.
indicated by a key
symbol.
Consult the serial label on the side of the
instrument for supply voltage requirements.
Fourth Issue September 2016
Output Option Card Connection Details
NO3 C3 NC3 NO4 C4 NC4
Relay 3
Relay 3
Relay 4
Normally
Normally
Common
Open
Closed
Contact
Contact
Contact
Relay 3
Relay 4
Common
Normally
Contact
Open
Contact
Output Option Card Connection Details.
Available Relays and Current Outputs Vary Depending On Card Type
Fitted Options- Power Supply:
23 mm
134 mm
Screw Clamp x 4
09:56
µS/cm
ii)
A: 12.28mA
ii)
-156mV
2.15Atm
ii)
MENU
F5
F4
F3
Gasket Seal
The MXD73 Panel Mount Instrument is designed to be ushed mounted and sealed in a
square cut-out in a panel, and is held in place with the four screw clamps provided
Power + Basic Outputs Connector
Power + Basic Outputs Connector
Power Supply
Earth Earth
Power Supply
"Live" In
"+" In
Protective Earth
(Must Be
Power Supply
Connected)
Power Supply
"Live" Out
Power Supply
"+"Out
(For Daisy Chaining)
(For Daisy Chaining)
"Neutral" Out
(For Daisy Chaining)
Power Supply
Power Supply
"Neutral In
85V-265V AC/DC Power Supply
18V-32V AC/DC Power Supply
Connection Details
Output Option Connector
I- - -
B
C
D
C5 NO5
C6 NO6
NO3 C3 NC3 NO4 C4 NC4
Relay 5
Relay 6
Current
Current
Relay 3
Common
Common
Output "-"
Output C "+"
Normally
Contact
Contact
(Common)
Open
Contact
Relay 4
Relay 5
Relay 6
Current
Current
Normally
Normally
Normally
Output B "+"
Output D "+"
Closed
Open
Open
Contact
Contact
Contact
Output Option Connector
A
B
NO3 C3 NC3 NO4 C4 NC4
C5 NO5
C6 NO6
Relay 3
Relay 3
Relay 4
Relay 5
Relay 6
Modbus A
Normally
Normally
Common
Common
Common
Connection
Open
Closed
Contact
Contact
Contact
(Inverting)
(0V Reference)
Contact
Contact
(Rx-/Tx-)
Relay 3
Relay 4
Relay 4
Relay 5
Relay 6
Modbus B
Common
Normally
Normally
Normally
Normally
Connection
Contact
Open
Closed
Open
Open
(Non-Inverting)
Contact
Contact
Contact
Contact
(Rx+/Tx+)
Modbus and 4 Relays Output Option Card Connection Details
24V
Output Option Card:
1-Current 2-Relays
Channel1:
Mains
3-Current 0-Relays
3-Current 4-Relays
5-Current 2-Relays
Modbus 4-Relays
PO Box 1142
Telephone: +64 (0) 9 234 4609
Pukekohe
email: helpdesk@quadbeam.co.nz
Auckland
Web: www.quadbeam.co.nz
2340
New Zealand
25 mm Min
Recomended Panel Cut-Out
For Cables
Should be 92mm X 92mm
And Connectors
89 mm Sq
SD Card
SD CARD
CONDUCTIVITY
CH1
Channel 1
C
G 1 2 3 4 5 6 7 8
Digital
A A B B G E C
H
C
1
Inputs
DIGITAL INPUTS
PH / REDOX
ECS CONDUCTIVITY
CH2
CH3
C
A A B B
- E E
+
R R
+ -
A A B B
R R
-
+
D D
+ -
C
H
H
3
2
Channel 2
Channel 3
-
NO3 C3 NC3 NO4 C4 NC4
C5 NO5
C6 NO6
I- B+ C+ D+
-
B
Output
-
I- B+ C+ D+
Power &
OUTPUT OPTION
-
Option
0/4 - 20mA
+
-
Standard Outputs
mA
L
N
1
2
-
E E E
0/4-20
I-
A+
NO1 C1 NC1 NO2 C2 NC2
-
Connector
A
A
85-250V
-
+
Exact Instrument Con guration Depends
Upon Ordered Speci cation
Power + Basic Outputs Connector
-
I- A+
NO1 C1 NC1 NO2 C2 NC2
-
Relay 2
Earth Earth
Normally
Relay 1
Protective Earth
Closed
Normally Open
(Must Be
Contact
Contact
Connected)
Current
Relay 1
Relay 2
Power Supply
Output "-"
Common
Common
"-" Out
Contact
(Common)
Contact
(For Daisy Chaining)
Relay 1
Relay 2
Normally Closed
"-" In
Normally Open
Contact
Contact
Standard Outputs Connection Details
Connection Details
Output Option Connector
I- - -
I- - -
I- - -
B
C
D
E
F
Relay 3
Relay 4
Current
Current
Current
Current
Normally
Common
Output "-"
Output C "+"
Output D "+"
Output "-"
Closed
Contact
(Common)
(Common)
Contact
Relay 3
Relay 4
Relay 4
Current
Current
Current
Current
Common
Normally
Normally
Output B "+"
Output "-"
Output E "+"
Output F "+"
Contact
Open
Closed
(Common)
Contact
Contact
5 Current Outputs 2 Relays Output Option Card Connection Details
C
Digital Input Connection Details
Digital Input Connector
G 1 2 3 4 5 6 7 8
Modbus C
Connection
Optional
Digital Input Connection Details
Cond
Channel2:
Cond
Channel3:
Cond
pH/Redox
pH/Redox
ECS
ECS
DO
DO
Aux mA IP
Aux mA IP
SS
SS
Slot
Current
Output A "+"
pH/Redox
ECS
DO
Aux mA IP
SS