User Interface Overview
4-20mA
Digital
Error
Outputs Setup
Inputs Setup
Messages
ALARM STATUS
SETPOINT STATUS
SETPOINT STATUS
LEDS
LEDS
LEDS
CURRENT DATE
MON 1 JUN 2009
09:56
517.2
CHANNEL PRIMARY
TANK 1
READING
CH1:
µS/cm
CHANNEL SECONDARY
12.3
°C
A: 12.28mA
i)
ii)
9.64
READING i
CHANNEL
CH2:
pH
CHANNEL ALARM
MESSAGES
25.0
-156mV
i)
°C
ii)
STATUS
23.3
TANK 3
CH3:
%
CHANNEL ID
28.0
°C
2.15Atm
i)
ii)
CHANNEL
CAL
CAL
MENU
LABEL
CONTEXT SENSITIVE BUTTON FUNCTIONS
Front Layout
For con guration and calibration information please consult the operational manuals
on the accompanying CD.
Current
Live Trends
Channels
Front Screen
Output
1, 2 & 3*
Setup
Bargraphs
*Optional Extra
Scrolling Menu Layout
CURRENT
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
INSTRUMENT
DATE / TIME
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
CH3: 23.3%
TEMP3: 28.0°C
READINGS
UNIT STATUS
MAIN MENU
FURTHER MENU
CHANNELS
CURSOR
PAGES ABOVE
CALIBRATION
SETPOINT / RELAYS
UNIT STATUS
4-20mA OUTPUTS
FURTHER MENU
DIGITAL INPUTS
PAGES BELOW
CONFIGURATION
CURRENT TIME
EXIT
CHANNEL SECONDARY
Main Menu Layout
READING ii
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
CH3: 23.3%
TEMP3: 28.0°C
SETPOINT 1 SETUP
OPTION POP-UP
CHANNEL:
CHANNEL 1 (COND)
TRIGGER
INPUT SOURCE:
SENSOR
HIGH
RANGE:
0 to 9.999 mS/cm
CURSOR
LOW
TRIGGER:
HIGH
BAND
ADDITIONAL
HIGH VALUE:
7.500mS/cm
LATCH HIGH
OPTIONS BELOW
MODE:
ON/OFF
LATCH LOW
EXIT
The default Access Code is: 1000
Pop-Up Option Layout
MXD75
Setpoint /
Relays Setup
Quick Start Guide
MON 1 JUN 2009
CH1: 517.2 µS/cm TEMP1: 12.3°C
09:56
CH2: 9.64 pH
TEMP2: 25.0°C
MXD75 Instrument Dimensions
CH3: 23.3%
TEMP3: 28.0°C
CHANNEL 1 SETUP
MODE:
SECURITY CODE
ON-LINE
UNITS:
ENTER ACCESS
SIEMENS(S/cm)
CODE
CELL CONSTANT:
1.000
0
* * *
RANGE:
AUTO
TEMP INPUT SENSOR:
PT1000
TEMPERATURE UNITS:
°C
EXIT
Security Access Pop-Up
F1
To protect the instrument setup
331 mm
from unauthorised or accidental
SKT5
tampering, a security access code
system is present. This is
implemented via the instrument's
menu system which operates in two
modes, "locked" as indicated by a
L
N
+
-
3
6
L
N
+
-
2
2
5
B+
padlock
symbol and "unlocked" as
_
1
1
4
85-250V
~
15W
0/4-20 mA
0/4-20 mA
OUTPUTS
5-6
indicated by a key
symbol.
Fourth Issue September 2016
LTH recommends using No.
10 x 1¼ inch round head
screws or similar for
mounting.
Ensure top screw head is 8
mm proud.
Care must be taken when
tting the unit on uneven
walls or surfaces. Do not
over stress the mounting
lugs.
Over tightening the
mounting screws could also
break the lugs.
Relay Connection Details
Relays 1 - 3 Connector
NO3 C3 NC3
NO2 C2 NC2
NO1 C1 NC1
NO1 C1 NC1 NO2 C2 NC2
NO3 C3
Relay 1
Relay 1
Relay 2
Relay 3
Normally
Normally
Common
Normally
Open
Closed
Contact
Open
Contact
Contact
Contact
Relay 1
Relay 2
Relay 2
Common
Normally
Normally
Contact
Open
Closed
Contact
Contact
Available Relays Vary Depending On Instrument Con guration
Digital Input Connection Details
Digital Input Connector
3
6
2
5 8
G
1 4 7
G
1
2
3
4
5
Digital Input Connection Details
Fitted Options- Power Supply:
110 mm
242 mm
Power Supply
HEADER A
HEADER C
MON 1 JUN 2009
MON 1 JUN 2009
517.2
517.2
09:56
09:56
µS/cm
µS/cm
CH1:
CH1:
i)
i)
12.3
12.3
°C
°C
ii)
ii)
A: 12.28mA
A: 12.28mA
9.64
9.64
CH2:
CH2:
pH
pH
25.0
25.0
°C
°C
-156mV
-156mV
i)
i)
23.3
23.3
ii)
ii)
CH3:
CH3:
%
%
28.0
28.0
2.15Atm
2.15Atm
i)
i)
°C
°C
ii)
ii)
CAL
CAL
MENU
MENU
COMMS A
F5
F2
F4
F3
COMMS B
HEADER D OR E
HEADER B
SKT7
SKT6
LINK
ACT
C+
-
A A B B G E C
3
6
G
SENSOR INPUT 3
-
A
A B B
SENSOR INPUT 2
E E
-
+
R R
+
-
2
5 8
G
A+
A+
D+ -
-
A A B B
SENSOR INPUT 1
-
R R
+
D D
+
-
1 4 7
G
DIGITAL
CH3
CONDUCTIVITY
SD CARD
OUTPUT
INPUTS
CH2
PH / REDOX
CH1
ECS CONDUCTIVITY
Power Connection Details
CAUTION!
Always remove the main power from the
system before any alterations to the wiring.
Ensure that both power lines are isolated. Make
sure that the power cannot be switched on by
8 mm
accident whilst the instrument is being
connected. For safety reasons an earth
300 mm
connection must be made to the earth terminal
of this instrument.
Local wiring and safety regulations should be
6 mm x
strictly adhered to when installing this
3 o
instrument. If the installation methods and
cable types recommended in this guide are
followed, then the instrument will achieve the
levels of EMC protection as speci ed in the
74 mm
74 mm
accompanying CD manual.
Drill Hole Dimensions
Consult the serial label on the side of the
instrument for supply voltage requirements.
Current Output & Modbus Connection Details
Relays 4 - 6 Connector
C6
NO6
C5
NO5
NO4 C4 NC4
A+
5-6
NC3
NO4 C4 NC4 C5 NO5 C6 NO6
Current
Output A+
Relay 3
Relay 4
Relay 4
Relay 5
Relay 6
Current
Normally
Normally
Normally
Common
Normally
Output B+
Closed
Open
Closed
Contact
Open
Contact
Contact
Contact
Contact
Current Output Connection Details
Relay 3
Relay 4
Relay 5
Relay 6
Common
Common
Normally
Normally
Contact
Contact
Open
Closed
Contact
Contact
Relay Connection Details
Temperature Connection Details
Sensor Input Connector
Sensor Input Connector
G
A A B B
A A B B
G
Link
Link
Link
6
7
8
RTD
RTD
3 Wire RTD
2 Wire RTD
Temperature Connection
Temperature Connection
24V
Output Option Card:
1-Current 2-Relays
Channel1:
Mains
3-Current 0-Relays
3-Current 4-Relays
5-Current 2-Relays
Modbus 4-Relays
PO Box 1142
Telephone: +64 (0) 9 234 4609
Pukekohe
email: helpdesk@quadbeam.co.nz
Auckland
Web: www.quadbeam.co.nz
2340
New Zealand
Current Outputs
Channel 2
/ Modbus RS485
Input
Digital
Channel 1
Channel 3
Relays
Inputs SD Card
Input
Input
Slot
Input
Ethernet
Port
(Future
Expansion)
L
N
+
-
3
6
C+
-
A A B B
SENSOR INPUT 3
R R
-
+
D D
+
-
3
6
G
L
N
+
-
2
2
5
B+
-
A
A B B
SENSOR INPUT 2
E E
-
+
R R
+
-
2
5 8
G
_
1
1
4
A+
A+
D+ -
-
A A B B G E C
SENSOR INPUT 1
1 4 7
G
85-265V
~
15W
0/4-20 mA
DIGITAL
0/4-20 mA
CH3
ECS CONDUCTIVITY
SD CARD
OUTPUTS
OUTPUT
INPUTS
CH2
PH / REDOX
5-6
CH1
CONDUCTIVITY
Earth Studs
Exact Instrument Con guration Depends
Upon Ordered Speci cation
Power Connector
Power Connector
L
N
N
L
+
-
+
-
L
N
L
-
+
+
Power Supply
Power Supply
Power Supply
"Live" Out
"Neutral" In
"+" Out
(For Daisy Chaining)
(For Daisy
Power Supply
Chaining)
"-" Out
Power Supply
Power Supply
"Live" In
"Neutral" Out
Power Supply
(For Daisy
(For Daisy Chaining)
"+" In
Chaining)
Earth
Earth
Earth
Earth
Protective Earth
Earth
Protective Earth
Earth
(Must Be Connected)
(Must Be Connected)
85V-265V AC/DC Power Supply
18V-32V AC/DC Power Supply
Connection Details
Connection Details
Current Output Connector
Modbus and Current Output Connector
B+
-
C+
F+
485
-
A-
B+
E+
485
A+
C
-
A+
-
D+
G
mA
485
mA
0/4-20 mA
MODBUS RS485
& 0/4-20 mA OUTPUT
OUTPUTS
- - -
A+
-
A-
B+
B+
C+
D+
E+
F+
mA
mA
485
485
485
Current
Current
Current
Current
Current
Modbus A
Output C+
Output E+
Output -
Output -
Output A+
Conenction
(Common)
(Common)
(Inverting)
Current
Current
Current
Current
(Rx-/Tx-) Modbus B
Output D+
Output F+
Output -
Output -
Connection
(Common)
(Common)
(Non-Inverting)
(Rx+/Tx+)
Modbus and Current Output
Connection Details
Available Current Output and Modbus Connections Vary Depending Upon
Instrument Con guration
Sensor Input Connector
Sensor Input Connector
A A B B T
A A B B
Link
Link
Thermistor
RTD
22K Thermistor
4 Wire RTD
Temperature Connection
Temperature Connection
(Only Available On Dissolved Oxygen Input Card)
Cond
Channel2:
Cond
Channel3:
pH/Redox
pH/Redox
ECS
ECS
DO
DO
Aux mA IP
Aux mA IP
SS
SS
N
-
Power Supply
"-" In
C
G
Modbus C
Connection
(0V Reference)
Optional
Cond
pH/Redox
ECS
DO
Aux mA IP
SS
Need help?
Do you have a question about the MXD75 and is the answer not in the manual?
Questions and answers