4. Attach your bracket.
Installation Guide
V.1.3
5. Prepare the RoadLog.
This guide is intended to help you get your RoadLog Electronic
Logging Device (ELD) installed, up and running quickly and easily.
Complete instructions for the RoadLog, including additional
installation information, can be found in the RoadLog Owner's
Manual or online at www.vdoroadlog.com/user.
BEFORE STARTING:
• To avoid damage to the vehicle or risk of electric shock, always
confirm the location of electric wires and air lines by consulting
the vehicle's owner's manual or your local vehicle repair facility.
If there is any uncertainty about the location of electric wires,
disconnect the vehicle battery before starting.
• Be careful when installing cable or wires to avoid kinks, knots
or twisting in the line.
• Be certain cable/wires are not rubbing on sharp edges.
RECOMMENDED
• Pen or
• Tape
pencil
measure
TOOLS:
1. Make sure you have the correct
installation kit for your vehicle!
RoadLog can be connected with 6-pin, 9-pin, 16-pin OBDII or
open-end "basic" cable. Only one cable is required. Choose
the one that fits your connector or choose the open-end if
you have no connector and will connect individual wires to the
vehicle. (For basic cable, installation by a professional shop is
recommended. When using the basic cable the ignition line
should be connected.)
Each cable is supplied with the basic installation bracket.
Y-Cables are an optional upgrade that retain an open cable
connector in the cab.
6 pin Y
6 pin direct
Open end
6. Connect cable to vehicle data port.
9 pin direct
9 pin Y with flange
9 pin Y with flange w/plastic nut
16 pin direct OBDII
16 pin Y OBDII
OBDII Light Duty Vehicle Converter
Volvo/Mack 2014 and newer
Volvo/Mack 2014 and newer
2. Choose your mounting option.
The "basic" bracket is included with each installation kit.
SUGGESTIONS FOR BRACKET MOUNTING
INSTALL BRACKET
SCREEN VIEW ANGLE
WITH DOUBLE-SIDED
IS ADJUSTABLE USING
ADHESIVE.
BRACKET KNOBS.
7. Install RoadLog into mount.
3. Choose your mounting location.
IMPORTANT: Choose a location that will allow easy
operation, but will not block your view of the road.
8. Load paper roll.
The unit must be placed a minimum of 10 inches (20 cm)
away from the driver.
F
E
D
A
B
9. Compliance sticker.
C
A. Top of the dash driver's left side*
D. Overhead console driver's left side
B. Top of the dash driver's center*
E. Overhead console driver's center side
C. Instrument panel driver's right side
F. Overhead console driver's right side
*Recommended locations
CO3649 RoadLog Installation GuideVer1.3_2016_BSv2.2.indd 1
Instructions for Open End "Basic" cable
The bracket can be attached with the adhesive foam pads. When
If using the Open End "Basic" Cable, follow the pin / wire color
using the adhesive foam pads be sure to clean the surface with a
assignments from the table below:
single direction swipe by using an alcohol prep pad supplied in an
installation kit. Let it dry and apply the tape with red peel side down
towards the dash. The tape will cure in 24-48 hours. The best
2
1
results are achieved when the surface is warm so you may want to
warm up the cab if the ambient temperature is low.
Unpack the ELD. Remove the service panel on the underside.
Pin
No
Insert the Battery. Connect the cable. Close the service panel.
1
2
3
Plug the battery
Check marking and plug
Close the service
Pry open the service
connector into the jack
the data cable. Attach
panel again and
4
panel with a small,
and place the battery into
the corrugated pipe.
insert the three
flathead screwdriver.
the holder.
screws included in
the box.
5
Recommended Cable Connect Direction
Harness leaves ELD
1
2
perpendicularly to display as
6
curves
and
shown in
7
RoadLog ELD TOP VIEW.
3
Routing harness under the
8
RoadLog ELD
rectangular cross-hatched area
TOP VIEW
depicted at rear of this ELD
9
illustration, and shown as curve
, is not recommended as it
can affect mobile performance.
10
11
Harness should leave ELD without curving, up to marking 'A'
(few inches apart from device), as depicted in RoadLog ELD
SIDE VIEW. Routing
should be avoided.
12
RoadLog ELD
4
SIDE VIEW
1
A
13
2
14
3
Run the cable from the RoadLog to the vehicle data port. The cable
can be run behind the interior dash panels via gaps between them
15
or by their removal where necessary.
Secure the cable out of the
driver's range of motion and
moving parts – coil up and
secure the excess cable by
using zip ties provided. Connect
16
the cable to the vehicle data
1
port. The device will power up
and be ready for the initial on
2
screen setup.
NOTE: If using the Open
End Cable, follow the wiring
Cable ports are usually located in the
indications shown below.
dash (1) or on the floor to the left of
the driver's seat (2).
Basic bracket: Place the RoadLog into the basic bracket and
install the knobs. Adjust the screen view angle and then tighten the
knobs.
To load the paper roll (Part
#3290-90010100), lift the access
panel at the top of the RoadLog,
lay the paper roll into the cavity
and pull the leading edge of the
paper forward, towards the
screen. The roll should be
inserted so that when the paper
comes out, it curls towards the
back of the unit.
Correct roll orientation
For installation and service questions contact:
Applying the included sticker to your
Technical Support
cab is optional, but doing so will ensure
Email: roadlog-support@vdo.com
anyone who sees it knows your vehicle
Electronic
Customer Service
is complying with ELD regulations.
Driver Lo gs
Tel.: (855)-ROADLOG, or (855) 762-3564
Fax: (800) 752-7224 or (610) 366-9837
Email: roadlog-sales@vdo.com
The basic cable has a total of 8 wires and only
Pins 1, 2 and 4 are connected: ignition, battery ( + )
4
6
8
10
12
14
16
and ground ( – ), respectively. The rest of the wires
3
5
7
9
11
13
15
have to be connected according to the table below
depending on the type of the vehicle.
(front view)
Signal
Description
Wire
Purpose
Notes /
Name
Color
Connection
Esta guía está prevista para ayudarle a instalar el dispositivo de registro
TERM15
Terminal 15
Brown
Input of vehicle ignition line
electrónico (ELD) RoadLog rápida y fácilmente. Las instrucciones
ignition signal
completas del RoadLog, incluida la información adicional de instalación,
TERM30
Terminal 30
Red
Supply line from vehicle
se encuentran en el Manual del propietario del RoadLog o en línea en
power supply
battery (+)
www.vdoroadlog.com/user.
voltage
J1939 (+)
CAN1 High
CAN_H connection to vehicle
Must be
ANTES DE COMENZAR:
Line
CAN bus (J1939-11/15)
twisted
together with
• Para evitar daños al vehículo o el riesgo de choque eléctrico, siempre
CAN1 Low
consulte el manual del propietario o un taller mecánico local para
Line
confirmar la ubicación de los alambres eléctricos y las mangueras de
TERM31
Terminal
Black
Ground line, GND
aire. Si no está seguro dónde se encuentran los alambres eléctricos,
31power
supply ground
desconecte la batería del vehículo antes de comenzar.
• Tenga cuidado de no torcer, doblar ni anudar los cables o alambres
J1939 (-)
CAN1 Low
CAN_L connection to vehicle
Must be
Line
CAN bus (J1939-11/15)
twisted
eléctricos durante la instalación.
together with
• Asegúrese de que ni los cables ni los alambres toquen orillas filosas.
CAN1 High
Line
HERRAMIENTAS
J1939_
CAN 1 ground
CAN_GND connection to
RECOMENDADAS:
GND
vehicle CAN bus (J1939-11/15)
J1708 (+)
RS484 line A
J1708 (+) connection to
vehicle SAE J1708 bus
J1708 (-)
RS484 line B
J1708 (-) connection to vehicle
1. ¡Asegúrese de que el juego de accesorios para
SAE J1708 bus
SPEED_IN
Speed pulse signal input
Vehicle speed pulse input
from vehicle speed sensor
(ISO16844)
RPM_IN
Revolution pulse signal input
RPM pulse input from vehicle
engine controller ECU
CAN2_H
CAN2
CAN_H connection to
Must be
HighLine
proprietary CAN bus (third
twisted
party device connection)
together with
CAN2 Low
Line
CAN2_L
CAN2 Low
CAN_L connection to
Must be
Line
proprietary CAN bus (third
twisted
party device connection)
together with
CAN2 High
Line
RS232_
RS232 data
RS232 data reception
RXD
reception line
(data input) line (for data
communication with third
party devices).
RS232_
RS232
RoadLog (DTE) requests
RTS
request to
the external equipment
send output
(DCE) to prepare to receive
data. When used for RS232
hardware flow control,
RoadLog uses this line to
indicate when it is able to
receive RS232 data.
RS232_
RS232 clear
The external equipment
CTS
to send input
(DCE) indicates if it is
ready to accept data from
RoadLog (DTE). When used
for hardware flow control,
RoadLog monitors this line
in order to see when the
2. Elija la opción de montaje.
external equipment is able to
receive RS232 data.
RS232_
RS232 data
RS232 data transmission
TXD
transmission
(data output) line (for data
line
communication with third
party devices).
3. Elija la ubicación de montaje.
Continental
Commercial Vehicles & Aftermarket
6755 Snowdrift Road
Allentown, PA 18106 USA
A. Sobre el tablero, lado izquierdo del conductor*
www.vdoroadlog.com
B. Sobre el tablero, en el centro del conductor*
VDO and RoadLog – Trademarks
C. En el panel de instrumentos, lado derecho del
of the Continental Corporation
conductor
©2016 Continental Automotive GmbH | Printed in Mexico
*Ubicaciones recomendadas
Guía de instalación del dispositivo de
4. Acople el soporte.
registro electrónico (ELD)
VDO RoadLog
V.1.3
5. Prepare el RoadLog.
Dirección recomendada para la conexión del cable
• Lápiz o
• Cinta
El arnés sale del ELD de
pluma
métrica
modo perpendicular a la
pantalla, como lo muestran las
curvas
SUPERIOR del RoadLog
ELD. No se recomienda pasar
la instalación sea el correcto para su vehículo!
el arnés por debajo del área
El RoadLog se puede conectar con un cable básico de extremo
rectangular sombreada que se
abierto o un cable con conector de 6 pines, 9 pines, o 16 pines
OBDII. Solamente se requiere un cable. Elija uno que le quede al
muestra en la parte trasera de
conector o elija uno de extremo abierto si no tiene un conector y
esta imagen del ELD y como
conectará los alambres individuales al vehículo. (Es recomendable
curva
que un profesional realice la instalación con cable básico. Cuando
el funcionamiento móvil.
se usa el cable básico, el cable del sistema de arranque debe estar
conectado.)
El arnés debe salir del ELD sin curvarse, hasta la marca 'A' (a
Los cables se suministran con un soporte básico. Los cables en Y
unas pulgadas del dispositivo), como se muestra en la VISTA
son una mejora opcional que conserva un conector de cable abierto
LATERAL del RoadLog ELD. Se debe evitar el recorrido
en la cabina.
Y de 6 pines
directo de 6 pines
Extremo abierto
directo de 9 pines
Y de 9 pines con reborde
Y de 9 pines con reborde
y tuerca de plástico
6. Conecte el cable al puerto de
OBDII directo de 16 pines
OBDII Y de 16 pines
Convertidor OBDII para
Volvo/Mack 2014 y más recientes
Volvo/Mack 2014 y más recientes
vehículos ligeros
El soporte "básico" se incluye en el juego de accesorios para
la instalación.
SUGERENCIAS PARA EL MONTAJE CON SOPORTE
EL ÁNGULO VISUAL DE LA
INSTALE EL SOPORTE CON
PANTALLA SE PUEDE AJUSTAR CON
CINTA ADHESIVA DOBLE CARA.
LAS PERILLAS DEL SOPORTE.
7. Instale el Roadlog en el soporte.
IMPORTANTE: Elija un lugar práctico para la operación, pero
que no obstruya la vista de la carretera. La unidad se debe
8. Instale el rollo de papel.
colocar a por lo menos 10 pulg. (20 cm) del conductor.
F
E
D
A
B
C
9. Etiqueta de cumplimiento.
D. En la consola del toldo, lado izquierdo del
conductor
E. En la consola del toldo, centro del conductor
F.
En la consola del toldo, lado derecho del
conductor
El soporte se puede instalar con las almohadillas adhesivas de hule
espuma. Cuando use las almohadillas adhesivas de hule espuma,
asegúrese de limpiar la superficie, con movimientos en una sola
dirección, con una toallita de alcohol suministrada en el juego de
instalación. Deje que se seque y aplique la cinta con el lado rojo
desprendible apuntando hacia el tablero. La cinta se seca en 24-48
horas. Para obtener mejores resultados es recomendable primero
calentar la cabina si la temperatura ambiental es baja.
Desempaque el ELD. Retire la tapa de servicio de la parte inferior.
Introduzca la pila. Conecte el cable. Cierre la tapa de servicio.
Abra el panel de servicio
Enchufe el conector
Verifique las marcas y
Cierre la tapa de
haciendo palanca con un
de la pila en la toma
enchufe el cable de datos.
servicio y atorníllela
destornillador pequeño
y coloque la pila en
Coloque el cubrecable de
con los tres tornillos
de cabeza plana.
su lugar.
tubo flexible.
incluidos en la caja.
1
2
y
en la VISTA
RoadLog ELD
3
VISTA
SUPERIOR
, ya que podría afectar
.
4
1
A
2
RoadLog ELD
3
VISTA LATERAL
datos del vehículo.
Tienda el cable del RoadLog al
puerto de datos del vehículo. El
cable se puede instalar por detrás
de los paneles del tablero interior,
1
en los espacios entre éstos o si es
necesario, los puede quitar.
2
Enrolle el exceso de cable de modo
que no le estorbe al conductor y
Los puertos para los cables usualmente se
asegúrelo con amarras de plástico.
encuentran en el tablero (1) o en el piso, del
lado izquierdo del asiento del conductor (2).
Conecte el cable en el puerto de
datos del vehículo. El dispositivo se encenderá y estará listo para la
configuración inicial en pantalla.
NOTA: Si usa el cable de extremo abierto, siga las indicaciones de
cableado indicadas abajo.
Soporte básico: Coloque el RoadLog en el soporte básico e instale
las perillas. Ajuste el ángulo visual de la pantalla y luego apriete las
perillas.
Para instalar el rollo de papel
(Pieza # 3290-90010100),
abra la tapa de acceso que se
encuentra en la parte superior
del RoadLog, coloque el rollo
de papel en la cavidad y jale la
orilla del papel hacia la pantalla.
El rollo se debe instalar de modo
que al salir el papel, se enrolle
hacia la parte trasera de la
unidad.
Orientación correcta del rollo
La aplicación de la etiqueta adjunta en
la cabina es opcional, pero al hacerlo se
Electronic
asegurará de que si alguien la ve sabrá
Driver Lo gs
que su vehículo cumple con las normas
de ELD.
(Continúa al reverso)
3/24/16 2:16 PM

Advertisement

loading

Summary of Contents for VDO RoadLog ELD

  • Page 1 (few inches apart from device), as depicted in RoadLog ELD recommended. When using the basic cable the ignition line CAN2 Low El arnés debe salir del ELD sin curvarse, hasta la marca ‘A’ (a SIDE VIEW.
  • Page 2 RS232. RoadLog (DTE). Cuando se usa VDO is a brand of Continental Automotive GmbH, one of the leading global suppliers of RS232_ RS232 prêt à L’équipement externe (DCE) indique para el control de flujo RS232 por Direct à...