Maintenance And Troubleshooting - Field Controls EvenAir T21WF Installation And User Manual

Thermostat with airflow control
Table of Contents

Advertisement

MAINTENANCE AND TROUBLESHOOTING

DAMPER OPERATION
Problem - No airflow to the sleeping area AND living
area registers
Turn system off immediately. Both dampers may be wired
backwards at the subbase or at the damper actuator (closing
rather than opening).
Problem - No airflow to the sleeping area OR living
area registers
Turn system off. One of the dampers may be wired backwards
at the subbase or at the damper actuator (closing rather
than opening).
Problem - When directing airflow to the sleeping area, the
airflow is actually directed to the living area, and when
directing the airflow to the living area, the airflow is actually
directed to the sleeping area.
Turn system off. Check if the dampers are switched (sleeping
area damper is wired to the living area terminals and the
living area damper is wired to the sleeping area terminals.)
COMFORT CONCERNS
Problem - Downstairs bedroom is too cold or too hot at night.
The Nighttime Airflow Control option directs more airflow to the
sleeping area and less airflow to the unoccupied living area. If
the downstairs bedroom is on the same HVAC trunk as the
living area, the downstairs bedroom may become uncomfortable
at night. Turn off the Nighttime Airflow Control option using the
User Options.
Field Controls
Model
Part Number
Number
580011101
T21
580011102
T21WF
580011301
TS51
580011302
TS52
580011401
AMT
580011405
IS
580011406
DS
MD-#
MD-LxH
SPARE PARTS AND ACCESSORY LIST
Description
Programmable wired thermostat w/ airflow control for GE equipment with 1H/1C, 2H/1C or 1H/2C,
or HP equipment with 2H/2C
Programmable wired thermostat w/ airflow control for GE equipment with 1H/1C, 2H/1C or 1H/2C,
or HP equipment with 2H/2C. WiFi Enabled
Wired temperature sensor for the sleep area. Single sensor installation.
Wired temperature sensor for the sleep area. Dual sensor installation.
Replacement modulating actuator control, 3 wire.
Replacement idler shaft for AMT and AMJ actuators.
Replacement drive shaft for AMT and AMJ actuators.
EvenAir Round Balance Damper, 3 Wire. Sizes - 4" - 20" diameter.
EvenAir Rectangular Balance Damper, 3 Wire. Sizes - 8", 10" and 12" Heights, up to 24" Length.
SENSOR INSTALLATION
Problem - nS message on thermostat.
Check that the sensor is wired correctly. Check for a short in
the sensor wiring.
Problem - Sleeping area temperature reading very high or
very low.
Check that the correct sensor(s) have been used. One TS51
sensor is used in a single sensor installation. Two TS52
sensors are used in a dual sensor installation.
Problem - The room temperature on the thermostat seems
too high or too low.
The thermostat is factory calibrated within 1 degree.
However, if a homeowner finds the temperature "feels"
too high or too low, the thermostat can be calibrated to
what the homeowner feels is the correct temperature using
Installer option 13 for the living area and option 14 for
the sleeping area.
page 15 of 16
P/N 780101703 3/18 Rev A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evenair t21

Table of Contents