13 Calibrate Living Area Temperature Sensor
Factory Default: None.
Range - +/-5
Use the UP/DOWN
Option
keys to change the
Living area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER.
14 Calibrate Sleeping Area Temperature Sensor
Factory Default: None.
Range - +/-5
Use the UP/DOWN
Option
keys to change the
Sleeping area
temperature to the
temperature that the
user feels is correct.
Touch NEXT or ENTER.
15 Airflow Update Time
Factory Default: 2 Min. Range: 1 to 20 Min.
This is the frequency, in minutes, that the damper
position is updated.
Use the
UP/DOWN
Option
keys to set the time
in minutes to update
the sleeping and
living area airflow.
Touch NEXT or ENTER.
16 Night Level LCD Backlight
Factory Default: On. Range: On or Off.
The LCD has a low
level backlight that
can be used as a
Night
night light.
Use the
UP
key to
turn the low level
backlight ON or touch the
DOWN
OFF.
Touch NEXT or ENTER.
17 Airflow Control, On or Off
Factory Default: On. Range: On or Off.
This option turns the automatic airflow control on
or off. If off, the dampers fully open, nighttime
airflow options are disabled and airflow is no
longer displayed on the thermostat.
Use the
UP
key to
Sleeping
select ON for airflow
Airflow %
control or touch the
Living
DOWN
key to select
OFF to disable
airflow control.
Touch NEXT or ENTER.
If Airflow Control was off and is now being turned on,
the Nighttime Airflow option can be turned on using the
User Options.
INSTALLER SECTION
18 Enable USER Airflow Control
o
Factory Default: Off. Range: On or Off.
Homeowners with an unusual work schedule,
home office, etc. may want to use this option.
When turned On, this option enables the user to
Living
turn off automatic airflow control in the User
Options. Airflow is adjusted by the homeowner.
NEXT
ENTER
Nighttime Airflow option is still enabled but can
be turned off using the User Options.
Use the
UP
select ON to enable
the user to turn off
o
automatic airflow
control in the user
options.
Sleeping
Touch NEXT or ENTER.
NEXT
ENTER
19 Upstaging Time
Factory Default: 10 min. Range: 5 to 30 min.
Use the
UP/DOWN
keys to set the time at
which second stage
heating or cooling is
activated.
Touch NEXT or ENTER.
For options 20 - 23, use the installer test
o
n the following page to determine the
NEXT
ENTER
max
imum allowable airflow.
20 Maximum Airflow in Heating to Sleeping Area
Factory Default: 150%. Range: 100% to 160%.
Use the
UP/DOWN
keys to select the
Option
maximum allowable
airflow in heating to
the sleeping area.
NEXT
ENTER
Touch NEXT or ENTER.
key to turn
21 Maximum Airflow in Cooling to the Sleeping Area
Factory Default: 140%. Range: 100% to 160%.
Use the
UP/DOWN
keys to select the
maximum allowable
airflow in cooling to
the sleeping area.
Touch NEXT or ENTER.
22 Maximum Airflow in Heating to the Living Area
Option
Factory Default: 150%. Range: 100% to 160%.
Use the
UP/DOWN
keys to select the
maximum allowable
NEXT
ENTER
airflow in heating to
the living area.
Touch NEXT or ENTER.
key to
Option
NEXT
ENTER
Option
NEXT
ENTER
Sleeping
Option
Heat
Airflow %
NEXT
ENTER
Sleeping
Option
Airflow %
Cool
NEXT
ENTER
Option
Heat
Airflow %
Living
NEXT
ENTER
page 12 of 16
23 Maximum Airflow in Cooling to the Living Area
Factory Default: 140%. Range: 100% to 160%.
Use the
UP/DOWN
Option
keys to select the
Airflow %
maximum allowable
Living
airflow in cooling to
the living area.
Touch NEXT or ENTER.
24 Maximum Temperature Differential
o
o
Factory Default: 2 F.
Range: 0 to 10 F
This is the maximum allowable temperature
difference between the sleeping and living area
temperatures. When the temperature difference is
equal to or greater than the allowed differential,
the airflow is adjusted.
Use the
UP/DOWN
Option
keys to select the
maximum allowable
temperature
difference between
the sleeping and
living area.
Touch NEXT or ENTER.
25 Factory Restore
WARNING! Factory Restore resets ALL settings.
To exit this option,
Option
touch
NEXT
or
ENTER, or the hidden
Back key.
To restore factory
Option
settings, touch the
UP
key to display
YES then touch
ENTER.
P/N 780101703 3/18 Rev A