WIZARD

Microwave Sensitivity(0-9)

Default = 7
Safety Output (0-1)
F1
0. No Redirection (6 wires)
1. All Relay Output (4 wires)
Motion Out
Presence Out
1. Active NO
Passive NC
2. Passive NC
Active NO
3. Passive NC
Passive NC
4. Active NO
Active NO

Detection Mode (1-4)

1.Bidirectional
2.Unidirectional
3.Unidirectional with MTF
4. Unidirectional Reverse
Auto Learn Time(0-6 or 9)
0 - 30 sec
3 - 5 min
6 - 60 min
1 - 1 min
4 - 10 min
9 - Infinity
2 - 2 min
5 - 20 min
(no learn)

Microwave Immunity(1-9)

1. Reduced
2. Normal
3. Increased
4-9 Enhanced

Infrared Immunity (1-3)

1. Low
2. Medium
3. High
Set-Up (0 or 9)
0. Setup
9. Factory Defaults
75.0180.05_RC_Guide_20080915_BW.indd 1
75.0180.05_RC_Guide_20080915_BW.indd 1
FALCON
Default = 7
(0.5 sec - 9 sec)
1. Active Output*
2. Passive Output**
Detection Mode (1-3)
1.Bidirectional
2.Unidirectional Approach
3.Unidirectional Depart
Rejection Mode
(1-5)
1. Detects all traffic: Pedestrian
& Vehicle
2. Detects All Traffic +Interference

Immunity

3. Low Pedestrian/Parallel Traffic
Rejection
4. Mid Pedestrian/Parallel Traffic
Rejection
5. High Pedestrian/Parallel Traffic
Rejection

Restore Default

Settings (1)
EAGLE

Sensitivity (0-9)

Default = 8

Hold Time (0-9)

(0.5 sec - 9 sec)
Relay Output (1-2)
1. NO Relay*
2. NC Relay**
Door Control (1-3)
F2
1. Normal
2. Permanent Detection
?
?
?
? ?
?
3. Permanent Non-Detection
Detection Mode (1-3)
1. Bidirectional
2. Unidirectional
3. Unidirectional with MTF
Immunity (1-9)
1. Reduced
3. Increased
2. Normal
4-9. Enhanced
Default Settings(1-2 or 9)
1.Normal
2.Boost
9.Restore
* Active output (Fail-Secure):
NC-COM circuit is closed and
NO-COM circuit is open.
** Passive output (Fail-Safe):
NO-COM circuit is closed and
NC-COM circuit is open.
Universal
Remote
Control Guide
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275
Phone: 1 412.249.4100
FAX: 1 888.523.2462
Toll Free: 1 800.523.2462
75.0180.05
20081021
10/21/2008 3:05:59 PM
10/21/2008 3:05:59 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DK-12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BEA DK-12

  • Page 1 WIZARD FALCON EAGLE Microwave Sensitivity(0-9) Sensitivity (0-9) Sensitivity (0-9) Default = 7 Default = 7 Default = 8 Safety Output (0-1) Hold Time (0-9) Hold Time (0-9) 0. No Redirection (6 wires) (0.5 sec - 9 sec) (0.5 sec - 9 sec) 1.
  • Page 2 BodyGuard & DK12 differences only Lock Sensitivity (0-9) Pattern Depth (1-6) Pattern Width (1-6) Default = 6 Closed, 7 Open Note: Not used on DK-12 1. Deep - Threshold On 1. Wide 4. Left Narrow (open & closed) 2. Medium - Threshold On (Open) 2.

Table of Contents