Loreme THL105 Configuration Handbook

Thermostat regulator for heating cables and ribbons

Advertisement

THERMOSTAT REGULATOR FOR
HEATING CABLES AND RIBBONS
CONFIGURATION HANDBOOK
THL105
LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3
Phone 03.87.76.32.51
Contact : Commercial@Loreme.fr - Technique@Loreme.fr
Download manual at : www.loreme.fr
REV 0.1 - 07/01/11
E 1

Advertisement

Table of Contents
loading

Summary of Contents for Loreme THL105

  • Page 1 THERMOSTAT REGULATOR FOR HEATING CABLES AND RIBBONS CONFIGURATION HANDBOOK THL105 LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr Download manual at : www.loreme.fr REV 0.1 - 07/01/11...
  • Page 2: Table Of Contents

    2) Recommendation of use .......................... p9 2.1) General remarks .......................... p9 2.2) Power Supply ..........................p9 2.3) Inputs / Outputs ........................... p9 WIRINGS ................................p10 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 3: Device Presentation

    TABLE OF CONTENTS Device Presentation The THL105 is a compact field mount thermostat for regulating heating cables and ribbons, allowing control of resistive load up to 3.5 kilowatts. The digital regulation allows to combine precision and ease of use. Temperature and setpoint are displayed on a large LCD display.
  • Page 4: Delay Configuration

    If the waiting time for action on the buttons exceeds 90 seconds then the device automatically returns to measurement mode without saving the new settings. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 5: Rs232 Link Setting

    Step 2: Setting of terminal emulation software (PC with windows). The terminal emulation software for PC « HyperTerminal » is resident in windows up to XP version. For later ver- sions, it is downloadable on : www.loreme.fr in download part ( http://www.loreme.fr/HyperTerm/htpe63.exe =>...
  • Page 6: Terminal Mode

    80 °C HYSTERESIS? Hysteresis setting (0 °C to 50 °C). 2 °C RETARD? Relay activation delay setting (0 s to 300 s). 0.5 s LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 7: Offset

     TABLE OF CONTENTS OFFSET Sometimes, it may be interesting to modify the measure by a simple terminal keyboard intervention. It can be used in many situations as sensor aging, an input refinement as a result of magnifying effect... To shift the measure, it is necessary: - To be in measure mode, - type on "+"...
  • Page 8: Firmware Update

    READY TO TRANSFER... The device is now in file waiting mode. This file is provide by LOREME. This file contain the firmware code in intel HEX format. Selected the « Transfer », « Send a text file ... » in the HyperTerminal menu.
  • Page 9: Emc Consideration

    1) Introduction To meet its policy concerning EMC, based on the Community directives 2014/30/EU & 2014/35/EU, the LOREME company takes into account the standards relative to this directives from the very start of the con- ception of each product. The set of tests performed on the devices, designed to work in an industrial environment, are made in accor- dance with IEC 61000-6-4 and IEC 61000-6-2 standards in order to establish the EU declaration of confor- mity.
  • Page 10: Wirings

    3 terminals RS232 link connector (under the cover) Cover (lift here) Phase Neutral Earth Earth phase Neutral PT100 sensor 230 Vac Load E 10 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...