Installation and Operating Manual
Switch Unit 40
VOTRONIC Switch Unit 40 works on basis of a bistable relay allowing very high capacities combined with a very low own
consumption. It suits especially as a remote-controlled main switch or load relay which is on long-term power. The
current carrying capacity conducts 40 A.
Switch Unit 40 can be mote-controlled by a normal switch (1 pol. ON / OFF).
Furthermore the consumer can be switched on and off through an emergency switch at the relay by hand.
The ranges of application are campers, intervention vehicles and boats:
Easy selection through ON / OFF switch
High switching current 40 A, short time to 60 A loadable
Applicable as battery main switch through ON / OFF switch (remote-controlled)
Switching state monitor is visible from the outside
Electronical delay prevent fast reactions like voltage drop or using strong consumer
Suitable for long-term usage due to a very low consumption of the Switch Unit (compliant EN13976)
No own electricity consumption if switched off with an external switch (remote-control)
Automatical disconnection by under voltage 8.5 V (minimum operating voltage of Switch Unit 40)
Switch Unit 40 cannot be used as a safety relay (emergency switch) to switch off dangerous
machines or engines. Please check safety regulations!
Please read this operating and installation manual thoroughly prior to connection and

Installation:

1.
Chose an installation place being cleaned and being protected from humidity and dust.
2.
The installation place of the unit should be chosen in such a way, that the cables of battery and consumers can
be as short as possible (losses) and that the pushbutton "EMERGENCY" is easily accessible. The unit should
never be covered by any objects.
3.
The switch unit is fastened solidly with screws in the casing flanges. The unit can be installed in any position.
But please make sure that the connection terminals are easy to reach
4.
Observe to fasten the connection cables in such a way, that neither high tensible force, nor high force of
pressure is acting on the terminals.

Connection:

(Please regard the connection plan)
ALWAYS DISCONNECT THE POWER SUPPLY TO THE BATTERY PRIOR TO WORKING ON THE
ELECTRIC SYSTEM TO AVOID SHORT-CIRCUITS!
It is recommendable to use connection cables of different colours to avoid malfunctions due to mixed up connections.
Observe: Only use red cables for plus "+" connection and black cables for minus "-" connection.
The 2pol. screw terminal is connected correctly when cable lengths show to the right and the crews show up. The unit
will not be damaged by eventual wrong polarization, but it will not be operating. Imperatively observe the cable cross
sections and the polarity. Insert the fuses near the battery (safety for cable fire).
Switching Capacity 12V or 24 V / 40 A
No. 2071

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Switch Unit 40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Votronic Switch Unit 40

  • Page 1 Switching Capacity 12V or 24 V / 40 A VOTRONIC Switch Unit 40 works on basis of a bistable relay allowing very high capacities combined with a very low own consumption. It suits especially as a remote-controlled main switch or load relay which is on long-term power. The current carrying capacity conducts 40 A.
  • Page 2 - 2 - Start-up: Switch ON: a.) Through external switch “ON” (Voltage at sensor cable > 10 V) b.) By hand with switch lever on the product – EMERGENCY towards “ON” Switch OFF: a.) By hand every time through external (remote-controlled) switch to „OFF“ b.) Automatically through reaching the minimal point of operating voltage (Undervoltage at sensor cable <...
  • Page 3 Never use the unit at locations where the risk of gas or dust explosion exists! • Switch Unit 40 cannot be used as a safety relay (emergency switch) to switch off dangerous machines or engines. •...
  • Page 4: Technical Data

    Subject to misprints, errors and technical modification without notice. All rights reserved, particularly the right of reproduction. Copyright  VOTRONIC 07/18. Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, 36341 LAUTERBACH/GERMANY Phone: +49 (0)6641 / 91173-0 Fax: +49 (0)6641 / 91173-20 E-mail: info@votronic.de...