6. Count Sensor Replacement

1. Remove feed tray.
2. Remove stay.
3. Remove slide guides.
4. Remove buckle fix screws.
5. Remove indication sign panel.
6. Remove bracket.
7. Remove buckle stopper shaft.
8. Pull out buckle.
9. Replace sensor P.C.B.
Buckle Stopper Shaft
B4-8W Screw (2 pcs)
B4-8W Screw (4 pcs)
(B4-8W screw : 4 pcs)
(B4-8W screw : 4 pcs)
(B3-16W screw : 6 pcs)
(B4-12W screw : 6 pcs)
(B4-8W screw : 4 pcs)
(B4-8W screw : 6 pcs)
(B4-8W screw : 2 pcs)
Count Sensor
Upper : Projector
Lower : Receiver
B4-8W Screw (4 pcs)
Spring
Spring Shaft
B4-12 W Screw (6 pcs)
Slide Guides
Indication Sign Panel
10
M5 X 10W Screw
B4-8W Screw
B3-16 W Screw (4 pcs)
Bracket
Feed Tray
Stay