USER GUIDE
Arm Manikin for IV Access Training
(BT-CSIV2)

Advertisement

loading

Summary of Contents for BT bt-csiv2

  • Page 1 USER GUIDE Arm Manikin for IV Access Training (BT-CSIV2)
  • Page 2: Cautions

    ⑧ Never clean the product with chemical substances such as solvent, benzene or thinner, as these may cause ignition, electric shock or cause the surface to deteriorate. ⑨ BT Inc. can change or adjust the product specification without any notice in order to improve the product.
  • Page 3: Table Of Contents

    2. Table of Contents 1. Cautions 2. Table of Contents 3. Components 4. Features and Functions 5. Installation 6. User Manual 7. Cleaning and Storage...
  • Page 4: Components

    3. Components (1) Left Arm manikin ① Arm manikin – 1ea ② Skin pad (Vein tube installed) – 2ea (2) Pump Driving Device ① Arm manikin mount (Volumetric pump installed) – 1ea ② Microcomputer (installed) – 1ea ③ Volume pump Control – 1ea ④...
  • Page 5: Features And Functions

    4. Features and Functions ① Arm manikin ② Skin pad (Vein tube installed) ③ Blood circulation controller (Installed in Arm Manikin Manikin Mount) ④ Timer switch ⑤ Rapid blood circulation switch ⑥ Blood IN connector ⑦ Blood OUT connector ⑧ Power supply connector...
  • Page 6 ⑨ Plastic bottle ⑩ Plastic bottle IN connector ⑪ Plastic bottle OUT connector ⑫ Connection tube ⑬ Mount...
  • Page 7: Installation

    5. Installation (1) Please arrange the product as the figure below. - Either Adapter or Battery can be used as the power supply. - Drop a few drops of simulated blood in a plastic bottle with some water and shake it. (2) Installation of Skin-Pad ①...
  • Page 8 (3) Connect the silicon tube as shown below.
  • Page 9: User Manual

    6. User Manual (1) As described in “5. Installation” , connect the power supply and connection tube. (2) If you connect the power supply properly, You can hear a short buzzer sound. (3) Press the Rapid Blood Circulation Switch to fill the blood vessel of Skin pad with simulated blood. (4) The purpose of Rapid Blood Circulation Switch is to fill simulated blood into the empty Skin-pad rapidly.
  • Page 10 (8) When you press the Timer Switch for 3 seconds, blood circulation will stop automatically. (9) After termination of the operation, you can hear the three buzzer sounds. (beep – beep --- beep) (10) If you want to restart, just press the Timer Switch again. (11) After finishing the practice, please keep the product as described in “Chapter 7.
  • Page 11: Cleaning And Storage

    7. Cleaning and Storage (1) After finishing the practice, you need to disconnect the white connector from the Plastic Bottle and then press the Rapid Blood Circulation Switch to remove blood in the tube. (2) Fill the bottle with clean water after expelling simulated blood. (You can reuse the simulated blood if you keep the blood in an empty container) (3) Reconnect the white connector to the Plastic bottle.