OPERATING MANUAL
The VXR-1000 Series is designed to provide extended
handheld coverage by repeating transmissions in both di-
rections through an existing high power mobile radio.
Reliability is assured by a highly integrated surface mount
circuit design and a aluminum extrusion chassis. Impor-
tant channel frequency data is stored in EEPROM, and is
easily programmable by dealers using a personal com-
puter and the Vertex Standard VPL-1 Programming Cable
and CE-22 Software.
Please take a few minutes to read this manual carefully.
The information presented here will allow you to derive
maximum performance from your VXR-1000. After read-
ing it, keep the manual handy for quick reference, in case
questions arise later on.
We're glad you joined the Vertex Standard team. Call on
us any time, because our business is communications.
Let us help you get your message across.
This device complies with Part 15 of the FCC rules.
Operation is subject to the condition that this de-
vice does not cause harmful interference.
Copyright 2013
Vertex Standard LMR, Inc.
All rights reserved.
E
1
3
3
7
7
5
0
3
No portion of this manual
may be reproduced
without the permission of
Vertex Standard LMR, Inc.
Vertex Standard LMR, Inc.
C
ONTROLS
Front Panel
Microphone Jack
Connect the microphone plug to this jack.
CHANNEL Selector Knob
This knob selects the operating channel.
PRI Indicator
When on, "PRI" indicates that the unit is at priority count
zero and will repeat all transmissions.
TX Indicator
When on, "TX" indicates that the repeater is transmitting to
the handheld.
COR Indicator
This lamp blinks red when the VXR-1000 is receiving a sig-
nal from a handheld, and glows red while the VXR-1000 is
receiving a sub-audible tone from the handheld.
MBL Indicator
This lamp blinks red when the Mobile is receiving signal from
repeater or base, and glows red while the Mobile is transmit-
ting to the repeater or base.
PWR Indicator
This is the main "P
O " indicator for the VXR-1000.
VOLUME Knob
This knob adjusts the receiver volume.
E
M
RROR
ESSAGE
No Channel Data
TX, COR, and PWR indicators Blinks
(Operating Channel is Vacant)
ARTS Out of Range
PWR indicator Blink
H
S
ARDWARE
ETTINGS
JP1004: Controls the output impedance of the transmit audio
line to the mobile radio.
Short: low-Z (600 Ω); open: high-Z (4.7 kΩ) *
JP1005: Controls the maximum drive level of the transmit au-
dio output to the mobile.
Short: low level output (0-100 mV)*; open: high level
output (0-5 V).
JP1001/1002/1003: Polarity of Power supply control.
Default setting: active high (JP1003: short).
VR1001: Mobile Microphone level
VR1002: Mobile RX Audio (External Modulation level)
VR1007: Mobile TX Audio (output level)
* default setting
The VXR-1000 has a fixed 3 minute time-out timer for base to
handheld transmissions. If the mobile COR is active for more
than 3 minutes it will send a error blip and cease transmission
until the mobile COR is inactive.
& C
ONNECTORS
Rear Panel
EXT SP (External Speaker)
An external loudspeaker may be connected to this 2-contact,
3.5-mm mini-phone jack.
DSUB 9-Pin Accessory Connector
External TX audio line-input, PTT, external RX audio line-
output, and other signals may be obtained from this connec-
tor for use with accessories.
P
A
IN
SSIGNMENT
Pin 1
GND
Pin 2
Mobile Transmit Audio
Pin 3
Power Supply Control
Pin 4
Mobile PTT Output
Pin 5
Vcc (13.8 V DC)
Pin 6
Moble Receive Audio
Pin 7
Mobile COR Detect
Pin 8
Mobile Microphone Audio
Pin 9
Mobile TX Detect / Mobile Micophone PTT
Antenna Socket
The Antenna socket is a standard 50 Ω BNC antenna connec-
tor.
F
D
UNCTIONAL
ESCRIPTION
When the user leaves the vehicle, they activate their mobile ra-
dio via its front panel or a separate switch. When the mobile ra-
dio is receiving a signal, the VXR-1000 will begin transmitting
on the hand-held's receive frequency. The user is able to hear
and respond to all radio traffic, including other hand-helds on the
same frequency. The repeater jumpers and potentiometers are
custom-configured for use with the particular mobile radio to
which it will be connected. The CE-22 software is used to pro-
gram the repeater for the required operating parameters.
T
O
RUNKING
PERATION
When the radio is connected to a trunking mobile you wish to
access the system from your handheld radio, key the handheld
briefly then release the PTT key. The radio will attempt to ac-
quire a voice channel on the trunking system by keying the mo-
bile for 200 mS and monitoring the "on-air detect" line from the
mobile. If the VXR-1000 does not see the radio transmit at all
(system is busy), it will send a low tone to the handheld to alert
you that the system is busy. The radio will automatically retry
every 5 seconds and send a "busy" tone to the handheld with
each unsuccessful attempt, to indicate progress of the call attempt.
If unsuccessful after 30 seconds, the radio will transmit an "in-
tercept" tone to alert the handheld that the call attempt failed.
When the VXR-1000 detects that the mobile is transmitting, it
will continue to monitor the "on-air detect" line until the trans-
mitter remains keyed for at least 250 mS to determine if the radio
is merely handshaking or retrying. After successful acquisition
of a voice channel, it will continue to hold the mobile's PTT ac-
tive for 2 seconds and transmit a "go-ahead" blip to the handheld.
You may then key their handheld to speak on the voice channel.
If you do not key up within the 2-second period, the radio will
un-key the mobile and send the "intercept" tone, as before.
S
PECIFICATIONS
GENERAL
150 - 174 MHz (VXR-1000V)
Frequency Range:
450 - 470 MHz (VXR-1000U)
16 Channels
Number of Channels:
12.5/25 kHz
Channel Spacing:
13.8V DC
Supply Voltage:
−30 °C to +60 °C
Ambient Temperature Range:
2.5 ppm
Frequency Stability:
50 Ω
RF Input-Output Impedance:
8 Ω
Audio Output Impedance:
Case Size (WHD):
111 x 25.4 x 136 mm
Weight:
400 g
RECEIVER
Circuit Type:
Double Conversion
Superheterodyne
Sensitivity
( EIA 12dB SINAD )
:
0.30 µV (VXR-1000V)
0.35 µV (VXR-1000U)
20 dB Quieting:
0.40 µV (VXR-1000V)
0.45 µV (VXR-1000U)
Squelch Threshold:
0.2 µV to 2 µV
Adjacent Channel Selectivity:
60 dB
Intermodulation Rejection:
60 dB
Spurious and Image Rejection: 60 dB
Conducted Spurious Emissions: −57 dBm
1 W into 8 Ω w/<5% THD
Audio Output:
Hum and Noise:
40 dB
TRANSMITTER
Power Output:
5.0/2.5/1.0/0.5 W
Modulation:
16K0F3E /11K0F3E
Maximum Deviation:
±5 kHz/2.5 kHz
Conducted Spurious Emissions: 60 dBc
FM Hum and Noise:
40 dB
O
A
PTIONAL
CCESSORIES
MH-53
Microphone
A8J
MLS-100
External Loudspeaker
VPL-1
Programming Cable
CE-22
Programming Software (for IBM PC/compatibles only)
FRB-4
Programming Interface Box
T9101411
Radio-to-Radio Cloning Connection Cable
(used with the FRB-4 Programming Interface Box)
W
P
ARRANTY
OLICY
Vertex Standard warrants, to the original purchaser only, its Ver-
tex Standard manufactured communications products against de-
fects in materials and workmanship under normal use and ser-
vice for a given period of time from the date of purchase.
Limited Warranty Details:
North America customers (USA and Canada):
http://www.vertexstandard.com/lmr/warranty-terms.aspx
Customers outside of North America:
Contact the authorized dealer in your country.
NOTICE
There are no user-serviceable points inside this transceiver.
All service jobs must be referred to your Authorized Ser-
vice Center or Network Administrator.

Advertisement

loading

Summary of Contents for Vexter Standart LMR VXR-1000

  • Page 1 ARRANTY OLICY Short: low level output (0-100 mV)*; open: high level mobile. If the VXR-1000 does not see the radio transmit at all Vertex Standard warrants, to the original purchaser only, its Ver- output (0-5 V). (system is busy), it will send a low tone to the handheld to alert tex Standard manufactured communications products against de- JP1001/1002/1003: Polarity of Power supply control.
  • Page 2 FRB-4 Caja de Conversión para Programación El VXR-1000 posee un temporizador fijo de 3 minutos de duración para las transmisiones que se realizan desde la base hacia los equipos manipula tal equipo dentro de los 2 segundos establecidos, el T9101411 Cable Conector de Duplicación de Radio a Radio...