Page 1
Installation Manual Installation and Maintenance Instructions The MINI Model Number: OES 6.08 mini, OES 3.10 mini, OES 6.10 mini, OES 10.10 mini, OES 6.10 2in1 mini Cleveland Range, LLC 1333 East 179 Street Cleveland, Ohio 44110 Phone: (216) 481-4900 Fax: (216) 481-3782 www.clevelandrange.com...
Page 2
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or Improper installation, adjustment, alteration, liquids in the vicinity of this or service or maintenance can cause property any other appliance. damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Page 3
CONVOTHERM STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CONVOTHERM products are warranted to the original purchaser to be free from defects in materials and workmanship under normal use and service for the standard warranty period of one year from date of installation or 18 months from date of shipment, whichever comes first.
INSTALLATION OF THE MINI Table of Contents Chapter Page GENERAL INFORMATION………………………………………………………………….. A. Product Information………………………………………………………………………... B. Model Number…………………………………….………………………………………... C. Serial Number and Equipment Record………………….………………………………. D. Product Information Plate…………………………………….…………………………… INSTALLATION INSTRUCTIONS………………………………………………………….. A. Laws, Codes and Regulations.…………………………………………………………… B. Inspect for Shipping Damage…………………………………………......C. General Instructions……………………………………………………………………….. D.
CHAPTER 1 GENERAL INFORMATION A. Product Information Cleveland Range assigns two product identification numbers to each MINI: a model number and a serial number. The model number identifies the product characteristics. The serial number identifies the individual unit. B. Model Number 1.
CHAPTER 2 INSTALLATION INSTRUCTIONS A. Laws, Codes, and Regulations This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians. 1. The installation of this appliance must conform with: a. The National Electrical Code, ANSI/NFPA 70 (latest edition), or the Canadian Electrical Code, CSA C22.2, or local codes, as applicable.
C. General Instructions 1. Select the MINI’s operating location. 2. Only install the MINI with the legs provided or with a Cleveland Range Stand designed specifically for a MINI. Never install this unit without legs unless it is installed on a Cleveland Range stand specifying that legs are not required in its instructions.
D. Install the MINI 1. Select a Location for the MINI a. For safe and efficient operation, observe the following criteria when selecting an operating location for a MINI b. Transport the MINI on its pallet. c. Passages and doors must be high enough and wide enough for a MINI and its pallet. See Table 2-1.
Page 12
OES 3.10/6.10 mini Dimensions and Clearances Dimension (inches) Model OES 3.10 mini 35.06 31.23 23.04 OES 6.10 mini 34.56 30.57 22.38 Appliance must be installed level Operating Clearances: Left-Right: 3”, Back: 3” Service Clearance: Above: 20” (ventilation) Allow extra clearance on the left side if the appliance has the optional hand shower. Note: the Easy touch control option increases the height by approximately 1 ¼...
Page 13
OES 10.10 mini Dimensions and Clearances Appliance must be installed level Operating Clearances: Left-Right: 3”, Back: 3” Service Clearance: Above: 20” (ventilation) Allow extra clearance on the left side if the appliance has the optional hand shower...
Page 14
OES 6.10 mini 2in1 Dimensions and Clearances Appliance must be installed level Operating Clearances: Left-Right: 3”, Back: 3” Service Clearance: Above: 20” (ventilation) Allow extra clearance on the left side if the appliance has the optional hand shower...
E. Water Connections for the MINI 1. Install Water Supply a. Install the water supply before positioning the MINI. b. Water supply line(s) must be designed so the MINI can be moved for service. c. Construct all supply lines up to the point of installing the MINI. d.
3. Connect Water Supply Lines The Installer/Owner is responsible for the correct water connection of the MINI. When connecting water supply lines observe the following instructions, and any and all other applicable national, state, and local codes and regulations: a. Connect the MINI to COLD WATER b.
Page 21
MINI Air/Water Column Check Valve (if required) (if required) Treated Water Min. ½” water line Filter Solenoid Main Cold Untreated Water Water Supply Solenoid Water Connection Pressure Reducer Main Water (if required) Shut Off Valve Figure 2-1 Cleveland Range Water Supply Arrangement MINI Min ½”...
Page 22
2 in1MINI Check Valve Air/Water Column if required) (if required) Water Supply Condenser Main Water Pressure Reducer Wash Rinse Water Shut Off Valve if required) Solenoid Filter Treated Injector Min. ¾” water line Figure 2-3 Cleveland Range Water Supply Arrangement for 2 in 1 Minis...
F. Electric Connections for the MINI 1. Install Electric Power Lines a. Check the rating plate to make sure the MINI is compatible with the local electric supply. The rating plate is located on the left side of the MINI. ...
G. General Information for All MINIs 1. Keep the vents on the bottom and top of the MINI clear, clean, and free of obstruction. 2. The MINI must be level. Level the MINI from the bottom: Use the height adjustable legs of the MINI or its Cleveland range Supplied Stand and a level so that the MINI is level front-to-back and side-to-side.
Page 25
3. Do not connect the drain outlet extension line directly into a floor drain or a sewer line. 4. Do NOT connect the MINI drain directly to drains or to the plumbing of any other equipment. 5. The drain line must be free air vented, have gravity flow from the MINI, and terminate outside the perimeter of the MINI.
CHAPTER 3 STARTUP PROCEDURE ELECTRIC SHOCK HAZARD DEATH, INJURY, or EQUIPMENT DAMAGE can result from touching any component inside a MINI when the power is connected to a MINI. Whenever possible disconnect the power while installing, servicing, or testing a MINI. When installation, service, or tests require power to be connected to a MINI;...
B. IN THE EVENT OF A POWER FAILURE Do NOT attempt to operate a MINI during a power failure! DEATH, INJURY, and EQUIPMENT DAMAGE can result. Follow the Power Failure Shutdown Instructions POWER FAILURE SHUTDOWN INSTRUCTIONS In the event of a power failure: Turn OFF the Main External Power Switch.