En 6. Control Panels For Elevel / Elevel; Functions Of The Elevel / Elevel; Initialising The Control System; Manually Adjusting The Height Of The Bench - GARANT mLevel User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
6.
Control panels for eLevel / eLevel+
7.

Functions of the eLevel / eLevel+

7.1.

Initialising the control system

The control system is initialised by pressing the UP 1 and DOWN 1 buttons
simultaneously, and keeping them depressed. This causes the drives to move
down to their mechanical end stop and then switch off automatically. At this
point the buttons can be released.
The control system acknowledges the completion of initialisation with
3 acoustic beeps. The control system is now ready for operation.
7.2.

Manually adjusting the height of the bench

Press the UP 1 button to raise the bench. Press the DOWN 1 button to lower
the bench.
The drives continue to run as long as the button is kept depressed.
NOTE: The function buttons UP 2 / DOWN 2 / P / Enter / HB are
deactivated.
7.3.

Save bench positions (memory function)

Adjust the bench to the desired position, using the UP 1 and DOWN 1
buttons.
Press the M button 3 times to access memory mode.
Then within approx. 5 seconds press one of the M1, M2 or M3 buttons to
save the set position(s).
The control system acknowledges the memory save operation with an
acoustic beep.
www.hoffmann-group.com
DE
DE
EN
FR
FR
IT
IT
ES
ES
19