Application Note CML Microcircuits CMX7143_FI-x Configuration Guide COMMUNICATION SEMICONDUCTORS Publication: AN/WData/7143/Config/5 November 2009 1 Introduction This document is intended to identify and illustrate the associated routing through the CMX7143 when using the 4FSK, GMSK and FFSK Function Images . In addition references to the C-BUS accessible registers will also be shown to provide easier understanding and control of the device.
Page 3
Application Note CMX7143_FI-x Configuration Guide C M X7143_FI2 4-Level FSK Packet-data M odem C H 3 / M O D1 E nable R SSI3 Transm it M ode $C 0, b9 R S S I G ain VB IA S 0=D isabled $C 1, b1-0 = 10 D ata M odulator...
Page 4
Application Note CMX7143_FI-x Configuration Guide CMX7143_FI3 FFSK/MSK Modem CH3 / MOD1 Enable RSSI3 Transmit Mode $C0, b9 RSSI Gain VBIAS 0=Disabled $C1, b1-0 = 10 Data Modulator $B1, b15-13 1=Enabled 000=0dB 001=3.2dB Raw Data 010=6.4dB Tx Mode 011=9.6dB Optional b14=0 Powersaved FFSK 100=12.8dB Tx Data Buffer...
Page 5
CML does not assume any responsibility for the use of any algorithms, methods or circuitry described. No IPR or circuit patent licenses are implied. CML reserves the right at any time without notice to change the said algorithms, methods and circuitry and this product specification. CML has a policy of testing every product shipped using calibrated test equipment to ensure compliance with this product specification.