Sharp PC7000A Service Manual page 47

Table of Contents

Advertisement

-
pC-7000A
PC-7100
Enter the sector testing range to be tested with a single command.
Depression of the [0] key with the [CR] or mere depression of the [CR] key
will assume the maximum range which is "128".
(a-3) Retrials
Retry count?
[0
4
The number of retrials must be specified.
When an error has been encountered in reading the data. retrials will be
conducted as many times as specified here.
(a-4) Error stop choice
Error stop? [O:Yes. 1: No]
=
~
It must be specified whether the test is to be interrupted or not when an
error is encountered in a middle of the re'ad/write test.
(a-5) Start
Test start? [O:Yes. 1: No]
=
~
Start of the test must be acknowledged.
Entry of [1] causes the control to return to (a-1) for an entry again.
Entry of [0] starts the test with Fig.DSK-4 on display.
Test pass count. binary address. and physical address [CCCRRSS] are
displayed on the lower left side of the screen with the test to the right of
it.
A hexadecimal number is used to represent the pass count and the binary
address. and an octal number is used to represent the physical address.
Pass N
Binary adrs [Ox]
=
~~~~
Test mode: Read
CCC.RR.SS
On the right side of the screen is displayed the number of errors by error
kinds using hexadecimal figure.
-45-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc7100

Table of Contents