  • Page 1 Installation instructions Egger Laminate Flooring with JUST clic! installation system...
  • Page 2 40 % and 70 % ƒ Laminate flooring from EGGER installed as a floating flooring configuration can be installed on all sub-floors which meet the above described requirements. This includes in particular: all types of screed including hot water-heated screed ƒ...
  • Page 3 Attention! The surface temperature of a heated floor structure may not exceed 28° C (83° F). EGGER laminate flooring is generally installed floating. When installing on mineral sub-floors, it is absolutely necessary to install a moisture protection film with an SD value ≥...
  • Page 4: Before The Installation

    On mineral sub-surfaces, however, a moisture protection film with an SD value ≥ 75 m must always be installed first, over the entire surface and extend up the walls. Exceptions are the use of EGGER Silenzio Duo (2 in 1 insulation underlay with integrated moisture protection) or a comparable 2 in 1 underlayer board.
  • Page 5: Installation

    Prior to installation/Installation Planning movement profiles Transition mouldings must be installed in the following areas and flooring sizes because of the natural movement behaviour of laminate flooring: door thresholds ƒ passageways ƒ angled areas ƒ room lengths and / or widths of more than 10 m ƒ...
  • Page 6 Installation Removal / Dismantling of Elements In order to replace installed panels without destroying them, you first have to unlock the entire row by tilting it and then offset the panels at the short ends while tilted. Proceed with due care in order to avoid damaging the tongue and groove. Class 31, 32 and 33 Commercial Applications PVAC glue (D3) PVAC glue (D3)
  • Page 7 Installation Door frames Remove this PVAC glue (D3) part For wooden door frames, we recommend undercutting them – with the approval of the customer – according to the thickness of ƒ the flooring and the underlay. Install the flooring underneath the door frame – leave the necessary expansion gaps. In the event that your installation job will ƒ...
  • Page 8: Cleaning And Maintenance

    No matter how hard-wearing your floor is, a laminate floor board may still get damaged. If the damage is slight, the problem can be easily solved with EGGER’s system-related repair paste Decor Mix & Fill. If the damage is more serious, a professional installer will be able to replace an entire panel.
  • Page 9 EGGER Holzwerkstoffe Wismar EGGER Drevprodukt Gagarin GmbH & Co. KG Ezhvinsky proezd, 1 Am Haffeld 1 215010 Gagarin 23970 Wismar Oblast Smolensk Germany Russia +49 3841 301-0 +7 48135 79-300 +49 3841 301-20222 +7 48135 79-311 flooring@egger.com info-ru@egger.com Advice, service and more:...